Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model

被引:18
|
作者
Marx, Mirko [1 ]
Ehrhardt, Jan [1 ]
Werner, Rene [2 ]
Schlemmer, Heinz-Peter [3 ]
Handels, Heinz [1 ]
机构
[1] Univ Lubeck, Inst Med Informat, D-23538 Lubeck, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Computat Neurosci, D-20246 Hamburg, Germany
[3] German Canc Res Ctr, Div Radiol, D-69120 Heidelberg, Germany
关键词
Respiratory motion; 4D MRI; Motion modeling; 4D CT simulation; RADIATION-THERAPY; RADIOTHERAPY; REGISTRATION; DEFORMATION; VARIABILITY; IMPACT; PHASE;
D O I
10.1007/s11548-013-0963-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Four-dimensional CT imaging is widely used to account for motion-related effects during radiotherapy planning of lung cancer patients. However, 4D CT often contains motion artifacts, cannot be used to measure motion variability, and leads to higher dose exposure. In this article, we propose using 4D MRI to acquire motion information for the radiotherapy planning process. From the 4D MRI images, we derive a time-continuous model of the average patient-specific respiratory motion, which is then applied to simulate 4D CT data based on a static 3D CT. The idea of the motion model is to represent the average lung motion over a respiratory cycle by cyclic B-spline curves. The model generation consists of motion field estimation in the 4D MRI data by nonlinear registration, assigning respiratory phases to the motion fields, and applying a B-spline approximation on a voxel-by-voxel basis to describe the average voxel motion over a breathing cycle. To simulate a patient-specific 4D CT based on a static CT of the patient, a multi-modal registration strategy is introduced to transfer the motion model from MRI to the static CT coordinates. Differences between model-based estimated and measured motion vectors are on average 1.39 mm for amplitude-based binning of the 4D MRI data of three patients. In addition, the MRI-to-CT registration strategy is shown to be suitable for the model transformation. The application of our 4D MRI-based motion model for simulating 4D CT images provides advantages over standard 4D CT (less motion artifacts, radiation-free). This makes it interesting for radiotherapy planning.
引用
收藏
页码:401 / 409
页数:9
相关论文
共 50 条
  • [41] Respiratory motion variations from skin surface on lung cancer patients from 4D CT data
    Gallego-Ortiz, Nicolas
    de Xivry, Jonathan Orban
    Descampe, Antonin
    Goossens, Samuel
    Geets, Xavier
    Janssens, Guillaume
    Macq, Benoit
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [42] Experimental quantification and analysis of organ motion artifacts in conventional CT-simulation: Conditions of 4D CT data acquisition
    Zygmanski, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1244 - 1244
  • [43] Simulation of motion defects in the 4D NCAT cardiac model.
    Segars, WP
    Lee, TS
    Tsui, BMW
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 142P - 142P
  • [44] On-Beam 4D CT Reconstruction Using Motion Amplitude Change Provided in Projection Images and Planning 4D CT
    Jung, J.
    Park, S.
    Kim, J.
    Yeo, I.
    Yi, B.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [45] Lung Segmentation in 4D CT Volumes Based on Robust Active Shape Model Matching
    Gill, Gurman
    Beichel, Reinhard R.
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2015, 2015
  • [46] Development of a Clinically Feasible Workflow of 4D MRI-Based Treatment Planning for Liver SBRT
    Han, S.
    Yin, F.
    Czito, B.
    Palta, M.
    Cai, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3588 - 3588
  • [47] A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans
    Kim, T.
    Yoon, J.
    Kang, S.
    Suh, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3684 - 3684
  • [48] Towards a Generic Respiratory Motion Model for 4D CT Imaging of the Thorax
    Fayad, H.
    Clement, J. F.
    Pan, T.
    Roux, C.
    Le Rest, C. Cheze
    Pradier, O.
    Visvikis, D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3975 - +
  • [49] Evaluating lung motion variations in repeated 4D CT studies using inverse consistent image registration
    Lu, W.
    Song, J.
    Christensen, G.
    Parikh, P.
    Zhao, T.
    Hubenschmidt, J.
    Bradley, J.
    Low, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2033 - 2033
  • [50] Evaluating lung motion variations in repeated 4D CT studies using inverse consistent image registration
    Lu, W.
    Song, J. H.
    Christensen, G. E.
    Parikh, P. J.
    Zhao, T.
    Hubenschmidt, J. P.
    Bradley, J. D.
    Low, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S606 - S607