Approximate solutions for flows in unconfined double porosity aquifers

被引:8
|
作者
Moutsopoulos, Konstantinos N. [1 ]
Papaspyros, John N. E. [1 ]
Fahs, Marwan [2 ]
机构
[1] Democritus Univ Thrace, Sch Engn, Dept Environm Engn, Lab Ecol Engn & Technol, Xanthi 67100, Greece
[2] Univ Strasbourg, Inst Terre & Environm Strasbourg, UMR 7063, CNRS,ENGEES, Strasbourg, France
关键词
Unconfined fractured aquifer; Analytical solutions; Aquifer -stream interactions; Pumping test; GROUNDWATER-FLOW; FRACTURED MEDIA; PUMPING TESTS; UNSATURATED FLOW; POROUS-MEDIA; WATER; WELL; INVERSION; HYDRODYNAMICS; SIMULATION;
D O I
10.1016/j.jhydrol.2022.128679
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although flow in unconfined double porosity aquifers occurs in most part of the world such as in karst and crystalline aquifers, their hydrodynamic behavior is still poorly understood. Especially, analytical or semi -analytical solutions for flow in unconfined double porosity (DP) aquifers are scarce. In this paper analytical solutions are proposed for two configurations involving groundwater discharge to a stream adjacent to an un-confined aquifer, and flow induced by pumping with constant extraction rate, respectively. The analytical so-lutions are obtained based on an h2-linearization technique of the full mathematical model and using a Laplace transform. The above technique has not been used before to investigate the behavior in DP aquifers. The newly developed analytical solution is in agreement with numerical solutions of the full mathematical model, for small to moderate drawdowns which are as high as 25% of the initial water table (case of the well pumping problem). This confirms on one side the correctness of the analytical solution and on the other side the reliability of the developed h2-linearization technique. On the contrary the conventional confined aquifer equations approach can be used only if the drawdown does not exceed 5% of the initial head values. As potential application examples, the estimation of the flow-rate from an aquifer to an adjacent water body, and the interpretation of pumping tests in unconfined double porosity aquifers, allowing to estimate the values of the models parameters, are proposed.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Extension of the Dupuit-Forchheimer Model for Non-Hydrostatic Flows in Unconfined Aquifers
    Zerihun, Yebegaeshet T.
    FLUIDS, 2018, 3 (02):
  • [22] SALTWATER UPCONING IN UNCONFINED AQUIFERS
    WIROJANAGUD, P
    CHARBENEAU, RJ
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1985, 111 (03): : 417 - 434
  • [23] IDENTIFICATION OF PARAMETERS IN UNCONFINED AQUIFERS
    SRIDHARAN, K
    RAMASWAMY, R
    RAO, NSL
    JOURNAL OF HYDROLOGY, 1985, 79 (1-2) : 73 - 81
  • [24] RELIABLE YIELD OF UNCONFINED AQUIFERS
    KHAN, LR
    MAWDSLEY, JA
    HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 1988, 33 (02): : 151 - 171
  • [25] SEEPAGE FLOW IN UNCONFINED AQUIFERS
    SHERCLIFF, JA
    JOURNAL OF FLUID MECHANICS, 1975, 71 (SEP9) : 181 - &
  • [26] APPROXIMATE ANALYTICAL SOLUTIONS FOR OVERLAND FLOWS
    GOVINDARAJU, RS
    KAVVAS, ML
    JONES, SE
    WATER RESOURCES RESEARCH, 1990, 26 (12) : 2903 - 2912
  • [27] Radon: An indicator of solute transport in double-porosity aquifers
    Atkinson, TC
    Barker, JA
    Ward, RS
    Low, RG
    NEW APPROACHES CHARACTERIZING GROUNDWATER FLOW, VOLS 1 AND 2, 2001, : 441 - 445
  • [28] Air and water flows induced by pumping tests in unconfined aquifers with low-permeability zones
    Kuang, Xingxing
    Jiao, Jiu Jimmy
    Zhang, Keni
    Mao, Deqiang
    HYDROLOGICAL PROCESSES, 2014, 28 (21) : 5450 - 5464
  • [29] Approximate Analytical Solution to Groundwater Velocity Variance in Unconfined Trending Aquifers in the Presence of Complex Sources and Sinks
    Ni, Chuen-Fa
    Li, Shu-Guang
    JOURNAL OF HYDROLOGIC ENGINEERING, 2009, 14 (10) : 1119 - 1125
  • [30] Scaling procedures for heterogeneous unconfined aquifers
    Polsinelli, James
    Kavvas, M. Levent
    HYDROLOGICAL PROCESSES, 2016, 30 (16) : 2880 - 2890