Heat transfer, energy conversion, and efficiency during cold discharge of a novel tetrabutylammonium bromide hydrate cold storage system

被引:16
|
作者
Wang, Fan [1 ]
Xia, Xinran [1 ]
Lv, Yuan [1 ]
Cheng, Chuanxiao [2 ]
Yang, Lei [1 ]
Zhang, Lunxiang [1 ]
Zhao, Jiafei [1 ]
机构
[1] Dalian Univ Technol, Minist Educ, Key Lab Ocean Energy Utilizat & Energy Conservat, Dalian 116024, Peoples R China
[2] Zhengzhou Univ Light Ind, Sch Energy & Power Engn, Zhengzhou 450002, Peoples R China
关键词
Hydrate cold storage; Cold discharge; Gas disturbance; Time-efficiency number; CLATHRATE HYDRATE; GAS-HYDRATE; GROWTH; PERFORMANCE; SLURRY; MORPHOLOGY; WATER; PCM;
D O I
10.1016/j.applthermaleng.2022.118462
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cold storage technologies using clathrate hydrates as working media have recently attracted more attention in the energy storage field because they undergo phase transitions with large latent heats and suitable temperatures for cold storage. However, the application of hydrate cold storage technologies is limited by the fact that the cold discharge mechanism is still unclear. Thus, this paper adopted the method of external melting by internal heat exchange to investigate the heat transfer, energy conversion and efficiency of a novel tetrabutylammonium bromide (TBAB) hydrate cold storage system during cold discharge. The system consisted of an internal circulating gas disturbance device and a metal spiral hydrate-on-coil heat exchanger. The heat transfer mechanism and cold discharge capacity, rate, and efficiency for different cold charge temperatures, flow rates and disturbance modes were compared and analyzed. A novel time-efficiency number was introduced to evaluate the comprehensive performance of the time, energy conversion and efficiency of cold discharge. The results showed that the heat exchange balance during the cold charge and discharge stages had a thermal buffering effect on the storage unit. Forced convection caused by gas disturbance resulted in a larger cold discharge capacity and reduced the discharge time by a factor of 3 compared to operation without gas disturbance. In addition, the cold discharge capacity gradually increased with decreasing cold charge temperature and increasing flow rate. The cold discharge efficiency was more than 83% under different conditions. A comparison showed that the time efficiency number tended to be larger with gas disturbance. This study showed that the time-efficiency number can be used for quantitative comparison of the cold discharge time and efficiency in hydrate cold storage systems.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Cold-to-electricity conversion using a piston based engine in cold energy storage (CES) system, part one: A theoretical study
    Du, Yanping
    Ding, Yulong
    JOURNAL OF THE ENERGY INSTITUTE, 2017, 90 (05) : 661 - 671
  • [32] Cold-to-electricity conversion using a piston based engine in cold energy storage (CES) system, part two: An experimental study
    Du, Y. P.
    Ding, Y. L.
    JOURNAL OF THE ENERGY INSTITUTE, 2018, 91 (01) : 120 - 132
  • [33] The formation process of self-coordinated microchannels with heat transfer enhancement advantage during phase change cold energy storage
    Ding, Zhaolei
    Jiang, Zhaoliang
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 48
  • [34] A theoretical and experimental study of a TBAB salt hydrate based cold thermal energy storage in an air conditioning system
    Wang, Xiaolin
    Zhai, Xiaoqiang
    Zhang, Huanqi
    Zhou, Lei
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2019, 13
  • [35] Experimental Investigations on Cold Recovery Efficiency of Packed-bed in Cryogenic Energy Storage System
    Dutta, Rohan
    Sandilya, Pavitra
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [36] POSSIBLE SOLUTIONS TO IMPROVE ENERGY EFFICIENCY FOR TYPICAL REFRIGERATION CONTROL SYSTEM IN CHINA COLD STORAGE
    Huang Zhihua
    Mikhailov, Anatolii
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 354 - 362
  • [37] Experimental Validation of a Novel CO2 Refrigeration System for Cold Storage: Achieving Energy Efficiency and Carbon Emission Reductions
    Wang, Yi-Zhou
    Fan, Yu-Wei
    Li, Xiao-Long
    Yang, Jian-Guo
    Zhang, Xin-Rong
    ENERGIES, 2025, 18 (05)
  • [38] Numerical and experimental investigations on melting heat transfer performance of PCM in finned cold thermal energy storage
    Lee, Yee-Ting
    Chien, Liang-Han
    Cheung, Fan-Bill
    Yang, An-Shik
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 210
  • [39] Thermodynamic Analysis of Pumped Thermal Energy Storage System Combined Cold, Heat, and Power Generation
    Wang, Yijing
    Yin, Yonggao
    Kang, Zhanxiao
    Fan, Jintu
    ENERGIES, 2025, 18 (03)
  • [40] Energy and exergy analyses of a novel liquid carbon dioxide energy storage system considering cold energy loss
    Zheng, Pingyang
    Yue, Yunkai
    Wang, Wenrui
    Shen, Daibing
    Hao, Jiahao
    Zhang, Zhentao
    Yang, Junling
    Li, Xiaoqiong
    JOURNAL OF ENERGY STORAGE, 2025, 113