摘要
Equivalent static wind loads (ESWLs) play an important role in the wind-resistant design of tall buildings. Traditionally, ESWLs of a tall building are derived based on the equivalence of the top deflection or the base force along the principal direction, which is easy to identify for a regular tall building. For flexible tall buildings with simple or complex shapes, wind-induced dynamic responses are three-dimensional, which often complicates the application of the ESWLs. Based on the time-domain dynamic analysis method, a new scheme is developed in this paper to model multiobjective equivalent static wind loads (M-ESWLs) on complex tall buildings. The possible non-Gaussian properties of wind-induced response processes have been taken into account in M-ESWLs by using non-Gaussian peak factors. Furthermore, a joint action reduction factor is carefully defined to reflect the partial correlations among multiple component responses. Finally, the new scheme is applied to a practical 43-story tall building with irregular geometric shapes to illustrate the application and effectiveness of the new method. In this work it was assumed that wind speeds do not depend on direction. Future research should include complementing this work by accounting for the effects of wind speed directionality. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Multiobjective Structural Layout Optimization of Tall Buildings Subjected to Dynamic Wind Loads
    Alanani, Magdy
    Brown, Tristen
    Elshaer, Ahmed
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (07)
  • [22] Wind load effects and equivalent static wind loads of three-tower connected tall buildings based on wind tunnel tests
    Ke, Shitang
    Wang, Hao
    Ge, Yaojun
    STRUCTURAL ENGINEERING AND MECHANICS, 2016, 58 (06) : 967 - 988
  • [23] Alongwind static equivalent wind loads and responses of tall buildings. Part II: Effects of mode shapes
    Zhou, Y
    Gu, M
    Xiang, HF
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 79 (1-2) : 151 - 158
  • [24] Investigation on Non-Gaussian Peak Factors for Wind Pressures on Domed Roof Structures
    Lo, Yuan-Lung
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2016, 19 (02): : 125 - 134
  • [25] Verification of correction factors for non-Gaussian effect on fatigue damage on the side face of tall buildings
    Ko, Nag-Ho
    INTERNATIONAL JOURNAL OF FATIGUE, 2008, 30 (05) : 779 - 792
  • [26] Gaussian vs non-Gaussian turbulence: impact on wind turbine loads
    Berg, Jacob
    Natarajan, Anand
    Mann, Jakob
    Patton, Edward G.
    WIND ENERGY, 2016, 19 (11) : 1975 - 1989
  • [27] AN ACROSSWIND EQUIVALENT STATIC WIND LOAD MODEL FOR RECTANGULAR SHAPED TALL BUILDINGS
    Cheng, Chiiming
    Wang, Jenmu
    Lai, Tzuching
    Tsai, Mingshu
    FUNDAMENTAL RESEARCH IN STRUCTURAL ENGINEERING: RETROSPECTIVE AND PROSPECTIVE, VOLS 1 AND 2, 2016, : 189 - 196
  • [28] An Acrosswind Equivalent Static Wind Load Model for Rectangular Shaped Tall Buildings
    Cheng C.-M.
    Lai T.-C.
    Wang J.
    Tsai M.-S.
    Journal of the Chinese Institute of Civil and Hydraulic Engineering, 2019, 31 (08): : 759 - 766
  • [29] Peak Factor Deviation Ratio Method for Division of Gaussian and Non-Gaussian Wind Pressures on High-Rise Buildings
    Huang, Dongmei
    Zhu, Zhaokun
    Xie, Hongling
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2022, 2022
  • [30] Wind tunnel test and equivalent static wind loads on large span station buildings
    Wu, Di
    Wu, Yue
    Sun, Ying
    Zhu, Yongjun
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2012, 33 (01): : 43 - 50