Quantitative investigation of phase retrieval from X-ray phase-contrast tomographic images

被引:0
|
作者
Moser, H. O. [1 ]
Banas, K. [1 ]
Chen, A. [1 ]
Nghia, T. Vo [1 ]
Jian, L. K. [1 ]
Kalaiselvi, S. M. P. [1 ]
Liu, G. [1 ]
Maniam, S. M. [1 ]
Gu, P. D. [1 ]
Wilkins, S. W. [2 ]
Gureyev, T. E. [2 ]
Mayo, S. C. [2 ]
Cholewa, M. [3 ]
Li, Z. J. [4 ]
机构
[1] Natl Univ Singapore, SSLS, Singapore 117603, Singapore
[2] CSIRO Mfg & Infrastruct Technol, Clayton, Vic 3169, Australia
[3] Monash Univ, Clayton, Vic, Australia
[4] Univ Freiburg, Freiburg, Germany
来源
关键词
phase contrast imaging; phase retrieval; reconstruction; micro manufacturing; synchrotron radiation;
D O I
10.1117/12.794497
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray phase-contrast tomographic microimaging is a powerful tool to reveal the internal structure of opaque soft-matter objects that are not easily seen in standard absorption contrast. In such low Z materials, the phase shift of X-rays transmitted can be important as compared to the absorption. An easy experimental set up that exploits refractive contrast fori-nation can deliver images that are providing detailed structural information. Applications are abundant in fields including polymer science and engineering, biology, biomedical engineering, life sciences, zoology, water treatment and filtration, membrane science, and micro/nanomanufacturing. However, available software for absorptive contrast tomography cannot be simply used for structure retrieval as the contrast fori-ning effect is different. In response, CSIRO has developed a reconstruction code for phase-contrast imaging. Here, we present a quantitative comparison of a micro phantom manufactured at SSLS with the object reconstructed by the code using X-ray images taken at SSLS. The phantom is a 500 gm thick 800 mu m diameter cylindrical disk of SU-8 resist having various eccentric cylindrical bores with diameters ranging from 350 gm to 40 mu m. Comparison of these parameters that are well known from design and post-manufacturing measurements with reconstructed ones gives encouraging results.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [32] PHASE-CONTRAST X-RAY MICROSCOPY STUDIES
    SCHMAHL, G
    RUDOLPH, D
    SCHNEIDER, G
    GUTTMANN, P
    NIEMANN, B
    OPTIK, 1994, 97 (04): : 181 - 182
  • [33] Benchtop phase-contrast X-ray imaging
    Gundogdu, O.
    Nirgianaki, E.
    Ismail, E. Che
    Jenneson, P. M.
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (12) : 1337 - 1344
  • [34] X-ray phase-contrast microscopy and microtomography
    Mayo, SC
    Davis, TJ
    Gureyev, TE
    Miller, PR
    Paganin, D
    Pogany, A
    Stevenson, AW
    Wilkins, SW
    OPTICS EXPRESS, 2003, 11 (19): : 2289 - 2302
  • [35] X-ray phase-contrast microscopy of paper
    Gureyev, Timur E., 2001, (84):
  • [36] Hard X-ray phase-contrast imaging
    Gao, DC
    Pogany, A
    Stevenson, AW
    Gureyev, T
    Wilkins, SW
    Mai, ZH
    ACTA PHYSICA SINICA, 2000, 49 (12) : 2357 - 2368
  • [37] Interlaced phase stepping in phase-contrast x-ray tomography
    Zanette, I.
    Bech, M.
    Pfeiffer, F.
    Weitkamp, T.
    APPLIED PHYSICS LETTERS, 2011, 98 (09)
  • [38] On X-ray phase retrieval from polychromatic images
    Gureyev, TE
    Wilkins, SW
    OPTICS COMMUNICATIONS, 1998, 147 (4-6) : 229 - 232
  • [39] Fast, non-iterative algorithm for quantitative integration of X-ray differential phase-contrast images
    Massimi, Lorenzo
    Buchanan, Ian
    Astolfo, Alberto
    Endrizzi, Marco
    Olivo, Alessandro
    OPTICS EXPRESS, 2020, 28 (26) : 39677 - 39687
  • [40] Phase retrieval microscopy for quantitative phase-contrast imaging
    Zhang, Y
    Pedrini, G
    Osten, W
    Tiziani, HJ
    OPTIK, 2004, 115 (02): : 94 - 96