Endocarditis due to Trichosporon beigelii 11 years after mitral valve replacement

被引:2
|
作者
Couto, Renata [1 ]
Couto, Gustavo [2 ]
Abrahao, Ingrid [1 ]
Compagnoni, Inae [1 ]
Carnio, Tatiane [1 ]
Tolentino, Julio [1 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Med Interna, Escola Med & Cirurgia, Rio De Janeiro, RJ, Brazil
[2] Hosp Sao Lucas, Serv Cirurgia Cardiaca, Nova Friburgo, RJ, Brazil
关键词
Endocarditis; Heart valve prosthesis; Trichosporon;
D O I
10.1016/j.repc.2018.04.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Trichosporon beigelii is a non-pathogenic fungus that can however become an opportunist agent of disseminating and potentially fatal infections, especially in immunocompromised patients. In the literature, there are only 11 published cases of infective endocarditis due to T. beigelii. Most of these cases involved immunocompetent individuals and the main risk factor was the presence of a prosthetic valve. The longest interval between surgery and endocarditis was eight years. In the present study, a case of prosthetic valve endocarditis due to T. beigeliiis reported in an immunocompetent patient 11 years after mitral valve replacement. As with similar cases, low clinical suspicion and negative blood cultures delayed the beginning of antifungal therapy and cardiac surgery. Considering the high mortality and severity of T. beigelii endocarditis, it should be considered when there is a prosthetic valve infection with negative blood cultures, irrespective of the time elapsed since the previous surgery. (C) 2020 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Brucella endocarditis with repeated mitral valve replacement
    Kalaycioglu, S
    Imren, Y
    Erer, D
    Zor, H
    Arman, D
    JOURNAL OF CARDIAC SURGERY, 2005, 20 (02) : 189 - 192
  • [22] MITRAL-VALVE REPLACEMENT FOR MITRAL REGURGITATION DUE TO LIBMAN-SACKS ENDOCARDITIS - REPORT OF A CASE
    MYEROWITZ, PD
    MICHAELIS, LL
    MCINTOSH, CL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1974, 67 (06): : 869 - 874
  • [23] Impressive left ventricular pseudoaneurysm mimicking a pericardial tamponade 5 years after mitral valve replacement for endocarditis
    Emmert, Maximilian Y.
    Wilhelm, Markus J.
    Frauenfelder, Thomas
    Weber, Benedikt
    Hoerstrup, Simon P.
    Falk, Volkmar
    EUROPEAN HEART JOURNAL, 2011, 32 (14) : 1820 - 1820
  • [24] Recurrent Syncope 31 Years After Mitral Valve Replacement
    Leitman, Marina
    Burgsdorf, Oleg
    Hendler, Alberto
    Sternik, Leonid
    Peleg, Eli
    Vered, Zvi
    CIRCULATION, 2013, 127 (12) : E507 - E508
  • [25] Nocardial endocarditis after mitral valve replacement: case report and review of the literature
    Timoteo, Ana T.
    Branco, Luisa M.
    Pinto, Margarida
    Bico, Pedro
    Ferreira, Rui C.
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2010, 29 (02) : 291 - 297
  • [26] Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement
    Ryo Wakabayashi
    Susumu Ide
    Takashi Ishida
    Satoshi Tanaka
    Mikito Kawamata
    JA Clinical Reports, 5
  • [27] Severe mitral regurgitation due to geometric changes in the mitral valve after surgical aortic valve replacement
    Wakabayashi, Ryo
    Ide, Susumu
    Ishida, Takashi
    Tanaka, Satoshi
    Kawamata, Mikito
    JA CLINICAL REPORTS, 2019, 5 (01)
  • [28] Redo Mitral Valve Replacement After Valve-in-Valve Transcatheter Mitral Valve Replacement
    Tsukioka, Yusuke
    Jeevanandam, Valluvan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [29] Endocarditis after mitral valve repair
    Gillinov, AM
    Faber, CN
    Sabik, JF
    Pettersson, G
    Griffin, BP
    Gordon, SM
    Hayek, E
    Di Paola, LM
    Cosgrove, DM
    Blackstone, EH
    ANNALS OF THORACIC SURGERY, 2002, 73 (06): : 1813 - 1816
  • [30] PARTIAL MITRAL-VALVE REPLACEMENT WITH A MITRAL HOMOGRAFT IN SUBACUTE ENDOCARDITIS
    DOSSCHE, K
    VANERMEN, H
    WELLENS, F
    THORACIC AND CARDIOVASCULAR SURGEON, 1994, 42 (04): : 240 - 242