The Measurement System for the Calibration of Particle Counters

被引:0
|
作者
Sramek, Jan [1 ,2 ]
Sperka, Jiri [2 ]
Jankovych, Robert [1 ]
机构
[1] Brno Univ Technol, Tech 2896 2, Brno 61669, Czech Republic
[2] Czech Metrol Inst, Okruzni 31, Brno 63800, Czech Republic
关键词
particle counter; nanoparticles; ISO; 21501; light scattering;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, there is a growing trend towards monitoring of the air quality in indoor areas of various laboratories and factories, as well as in outdoor public areas (air hygiene). For this purposes, portable measurement devices particle counters are usually employed. Due to the necessity to ensure adequate metrological traceability of these systems and to meet the ISO 21501 standard, the calibration procedure has to be performed in proper quality.
引用
收藏
页码:392 / 396
页数:5
相关论文
共 50 条
  • [22] Particle counters
    不详
    MICRO, 1995, 13 (10): : 32 - 32
  • [23] Performance evaluation of three optical particle counters with an efficient "multimodal" calibration method
    Heim, Michael
    Mullins, Benjamin J.
    Umhauer, Heinz
    Kasper, Gerhard
    JOURNAL OF AEROSOL SCIENCE, 2008, 39 (12) : 1019 - 1031
  • [24] Calibration system with an indirect photoelectric charger for legislated vehicle number emission measurement counters in the single counting mode
    Grob, B.
    Wolf, J. -C.
    Kiwull, B.
    Niessner, R.
    JOURNAL OF AEROSOL SCIENCE, 2014, 70 : 50 - 58
  • [25] Calibration and measurement analysis of a cloud particle detection system based on polarization detection
    Jiang, Fuyuan
    Zhang, Yang
    Bu, Lingbing
    Chu, Chenxi
    APPLIED OPTICS, 2019, 58 (36) : 9777 - 9785
  • [26] CALIBRATION OF KNOLLENBERG FSSP LIGHT-SCATTERING COUNTERS FOR MEASUREMENT OF CLOUD DROPLETS
    PINNICK, RG
    GARVEY, DM
    DUNCAN, LD
    JOURNAL OF APPLIED METEOROLOGY, 1981, 20 (09): : 1049 - 1057
  • [27] MEASUREMENT OF MEAN CELL-VOLUME USING ELECTRONIC PARTICLE COUNTERS
    ENGLAND, JM
    DOWN, MC
    BRITISH JOURNAL OF HAEMATOLOGY, 1976, 32 (03) : 403 - 409
  • [28] Filter efficiency measurement with optical particle counters - limitations and error sources
    Univ of Vienna, Vienna, Austria
    Sep Sci Technol, 9 (1225-1240):
  • [29] Filter efficiency measurement with optical particle counters - Limitations and error sources
    Szymanski, WW
    Cheng, YH
    Tsai, CJ
    SEPARATION SCIENCE AND TECHNOLOGY, 1998, 33 (09) : 1225 - 1240
  • [30] Workplace aerosol mass concentration measurement using optical particle counters
    Goerner, Peter
    Simon, Xavier
    Bemer, Denis
    Liden, Goran
    JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (02): : 420 - 428