Improved exergoeconomic analysis of a retrofitted natural gas-based cogeneration system

被引:29
|
作者
Luo, Xianglong [1 ,2 ]
Hu, Jiahao [1 ]
Zhao, Jun [2 ]
Zhang, Bingjian [3 ]
Chen, Ying [1 ]
Mo, Songping [1 ]
机构
[1] Guangdong Univ Technol, Guangzhou Higher Educ Mega Ctr, Sch Mat & Energy, Guangzhou 510006, Guangdong, Peoples R China
[2] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ene, Minist Educ China, Tianjin 300072, Peoples R China
[3] Sun Yat Sen Univ, Sch Chem & Chem Engn, Key Lab Low Carbon Chem & Energy Conservat Guangd, Guangzhou 510275, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Exergoeconomic analysis; Residue cost allocation; Cogeneration system; Retrofit; WASTE HEAT-RECOVERY; THERMOECONOMIC ANALYSIS; POWER PRODUCTION; FLUE-GAS; STRUCTURAL THEORY; ENERGY-SYSTEMS; OPTIMIZATION; PLANT; COST; CYCLE;
D O I
10.1016/j.energy.2014.05.068
中图分类号
O414.1 [热力学];
学科分类号
摘要
Waste heat recovery has been commonly accepted as an efficient, clean, reliable, and promising approach to increase the utilization efficiency of primary energy and reduce the pollutant emissions. A RNGCS (retrofitted natural gas-based cogeneration system), in which domestic hot water is heated by the waste heat of condensing steam and exhaust gas, is presented to replace the ONGCS (original natural gas-based cogeneration system), in which the domestic hot water is heated by bleeding steam. The RNGCS and ONGCS are modeled and simulated using Cycle-Tempo. An IECA (improved exergoeconomic analysis) incorporating waste exergy cost allocation and a TECA (traditional exergoeconomic analysis) without considering waste exergy cost allocation are applied to these two cogeneration systems to achieve the unit exergoeconomic cost of products. The IECA shows a reasonable result that the unit exergoeconomic cost of power, steam, and domestic hot water of the RNGCS are lower than those of the ONGCS. However, the TECA shows an unreasonable result that the unit exergoeconomic cost of domestic hot water generated from waste heat recovering in the RNGCS is much higher than that of the domestic water generated from high-grade bleeding steam heating in the ONGCS. The comparison proved that the IECA is more general and more reasonable for the presented types of waste heat recovery projects. In addition, economic analysis and sensitivity analysis based on IECA are also performed to show the superiority of the RNGCS. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:459 / 475
页数:17
相关论文
共 50 条
  • [1] Assessment of potential for natural gas-based cogeneration in Thailand
    Gvozdenac, Dusan
    Menke, Christoph
    Vallikul, Pumyos
    Petrovic, Jovan
    Gvozdenac, Branka
    ENERGY, 2009, 34 (04) : 465 - 475
  • [2] Exergoeconomic analysis of an absorption refrigeration and natural gas-fueled diesel power generator cogeneration system
    Ponce Arrieta, Felipe Raul
    Sodre, Jose Ricardo
    Mateus Herrera, Mario David
    Barros Zarante, Paola Helena
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 36 : 155 - 164
  • [3] Experimental results and exergoeconomic analysis of a natural gas small scale cogeneration plant
    Federal University of Santa Catarina, Department of Mechanical Engineering, Campus Universitário - Trindade, Florianópolis - SC
    88040-900, Brazil
    ECOS - Int. Conf. Effic., Cost, Optim., Simul. Environ. Impact Energy Syst., (625-634):
  • [4] Advanced exergoeconomic analysis and mathematical modelling of the natural gas fired gas turbine unit used for industrial cogeneration system
    Caglayan, Hasan
    Caliskan, Hakan
    Hong, Hiki
    Caliskan, Nesrin
    Kale, Utku
    Kilikevicius, Arturas
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [5] Using machine learning approaches to model and optimize a combined solar/natural gas-based power and freshwater cogeneration system
    Shakibi, Hamid
    Shokri, Afshar
    Assareh, Ehsanolah
    Yari, Mortaza
    Lee, Moonyong
    APPLIED ENERGY, 2023, 333
  • [6] Exergoeconomic results of cogeneration system with a gas turbine and absorption cooling system
    Cidade Cavalcanti, Eduardo Jose
    INTERNATIONAL JOURNAL OF EXERGY, 2017, 24 (2-4) : 107 - 132
  • [7] System study on natural gas-based polygeneration system of DME and electricity
    Bin, Chen
    Jin Hongguang
    Lin, Gao
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (08) : 722 - 734
  • [8] Multiobjective optimization for exergoeconomic analysis of an integrated cogeneration system
    Zhang, Li
    Pan, Zhen
    Yu, Jingxian
    Zhang, Na
    Zhang, Zhien
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (05) : 1868 - 1881
  • [9] Exergy Analysis and Retrofitting of Natural Gas-based Acetylene Process
    Wang Zhifang
    Meng Danxing
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (05) : 812 - 818
  • [10] Thermodynamic and exergoeconomic analysis of an innovative cogeneration of power and freshwater based on gas turbine cycle
    Wang, Tianliang
    Tan, Hong
    ENERGY, 2023, 285