Exergoeconomic analysis of an absorption refrigeration and natural gas-fueled diesel power generator cogeneration system

被引:12
|
作者
Ponce Arrieta, Felipe Raul [1 ]
Sodre, Jose Ricardo [1 ,2 ]
Mateus Herrera, Mario David [1 ]
Barros Zarante, Paola Helena [1 ]
机构
[1] Pontificia Univ Catolica Minas Gerais, Dept Mech Engn, Av Dom Jose Gaspar 500, BR-30535901 Belo Horizonte, MG, Brazil
[2] Birmingham City Univ, Sch Engn & Built Environm, Curzon St, Birmingham B4 7XG, W Midlands, England
关键词
Natural gas; Cogeneration; Absorption refrigeration; Power generation; Exergoeconomic analysis; PERFORMANCE; ENGINE; EMISSIONS; DRIVEN; COMBUSTION; CHILLER; CYCLE;
D O I
10.1016/j.jngse.2016.10.022
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This work presents a thermoeconomic analysis of a cogeneration system using the exhaust gas from a natural gas-fueled diesel power generator as heat source for an ammonia-water absorption refrigeration system. The purpose of the analysis is to obtain both unit exergetic and exergoeconomic costs of the cogeneration system at different load conditions and replacement rates of diesel oil by natural gas. A thermodynamic model of the absorption chiller was developed using the Engineering Equation Solver (EES) software to simulate the exergetic and exergoeconomic cogeneration costs. The data entry for the simulation model included available experimental data from a dual-fuel diesel power generator operating with replacement rates of diesel oil by natural gas of 25%, 50% and 75%, and varying engine load from 10 kW to 30 kW Other required data was calculations using the GateCycle software, from the available experimental data. The results show that, in general, the cogeneration cold unit exergetic and exergoeconomic costs increases with increasing engine load and decreases with increasing replacement rate of diesel oil by natural gas under the conditions investigated. Operating with 3/4 of the rated engine power and replacing 50% of diesel oil by natural gas, the exergoeconomic cost of the produced power is increased by 75%, and the exergoeconomic cost of the produced cold is decreased by 17%. The electric power unit exergetic and exergoeconomic costs indicate that the replacement of diesel oil by natural gas is feasible in the present considerations for engine operation at medium and high loads. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 164
页数:10
相关论文
共 50 条
  • [1] Thermoeconomic assessment of an absorption refrigeration and hydrogen-fueled diesel power generator cogeneration system
    Mateus Herrera, Mario David
    Ponce Arrieta, Felipe Raul
    Sodre, Jose Ricardo
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (09) : 4590 - 4599
  • [2] Gas-fueled diesel power an attractive alternative
    Astroem, Torsten J.
    Cogeneration and Competitive Power Journal, 1995, 10 (01):
  • [3] Combustion and emission characteristics of a natural gas-fueled diesel engine with EGR
    Abdelaal, M. M.
    Hegab, A. H.
    ENERGY CONVERSION AND MANAGEMENT, 2012, 64 : 301 - 312
  • [4] Absorption refrigeration systems in cogeneration - Thermoeconomic analysis of a system using natural gas in a brewery.
    Gallego, AG
    Martins, G
    Nebra, SA
    OCOS 2000: FROM THERMO-ECONOMICS TO SUSTAINABILITY, PTS 1-4, 2000, : 1597 - 1608
  • [5] Emission characterization and evaluation of natural gas-fueled cogeneration microturbines and internal combustion engines
    Canova, Aldo
    Chicco, Gianfranco
    Genon, Giuseppe
    Mancarella, Pierluigi
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2900 - 2909
  • [6] Improved exergoeconomic analysis of a retrofitted natural gas-based cogeneration system
    Luo, Xianglong
    Hu, Jiahao
    Zhao, Jun
    Zhang, Bingjian
    Chen, Ying
    Mo, Songping
    ENERGY, 2014, 72 : 459 - 475
  • [7] Exergoeconomic results of cogeneration system with a gas turbine and absorption cooling system
    Cidade Cavalcanti, Eduardo Jose
    INTERNATIONAL JOURNAL OF EXERGY, 2017, 24 (2-4) : 107 - 132
  • [8] Extensive thermodynamic and economic analysis of the cogeneration of heat and power system fueled by the blend of natural gas and biogas
    Zareh, A. Darabadi
    Saray, R. Khoshbakhti
    Mirmasoumi, S.
    Bahlouli, K.
    ENERGY CONVERSION AND MANAGEMENT, 2018, 164 : 329 - 343
  • [9] Exergoeconomic evaluation and optimisation of a novel combined power and absorption-ejector refrigeration cycle driven by natural gas
    Sharifi, Mohammad Amin Rokn
    Khalilarya, Shahram
    INTERNATIONAL JOURNAL OF EXERGY, 2016, 19 (02) : 232 - 258
  • [10] Matching and characteristics of a gas fueled system in a natural gas and diesel dual fueled engine
    Zhang, J.
    Gao, Q.
    Sun, Z.
    Sun, J.
    Zhang, Z.
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2001, 32 (02): : 8 - 10