Cerebellar Transcranial Magnetic Stimulation: The Role of Coil Geometry and Tissue Depth

被引:106
|
作者
Hardwick, Robert M. [1 ,2 ]
Lesage, Elise [2 ]
Miall, R. Chris [2 ]
机构
[1] Johns Hopkins Univ, Dept Phys Med & Rehabil, Baltimore, MD USA
[2] Univ Birmingham, Sch Psychol, Birmingham B15 2TT, W Midlands, England
基金
欧盟第七框架计划; 英国惠康基金;
关键词
Cerebellum; TMS; Cerebello brain inhibition; Cerebellar brain inhibition; TMS coil geometry; Deep TMS; Figure-of-eight coil; Double cone coil; Batwing coil; THETA-BURST STIMULATION; HUMAN MOTOR CORTEX; CORTICOSPINAL EXCITABILITY; LATERAL CEREBELLUM; HUMANS; INTENSITY; THRESHOLD; DISTANCE; BRAIN; RTMS;
D O I
10.1016/j.brs.2014.04.009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: While transcranial magnetic stimulation (TMS) coil geometry has important effects on the evoked magnetic field, no study has systematically examined how different coil designs affect the effectiveness of cerebellar stimulation. Hypothesis: The depth of the cerebellar targets will limit efficiency. Angled coils designed to stimulate deeper tissue are more effective in eliciting cerebellar stimulation. Methods: Experiment 1 examined basic inputeoutput properties of the figure-of-eight, batwing and double-cone coils, assessed with stimulation of motor cortex. Experiment 2 assessed the ability of each coil to activate cerebellum, using cerebellar-brain inhibition (CBI). Experiment 3 mapped distances from the scalp to cerebellar and motor cortical targets in a sample of 100 subjects' structural magnetic resonance images. Results: Experiment 1 showed batwing and double-cone coils have significantly lower resting motor thresholds, and recruitment curves with steeper slopes than the figure-of-eight coil. Experiment 2 showed the double-cone coil was the most efficient for eliciting CBI. The batwing coil induced CBI only at higher stimulus intensities. The figure-of-eight coil did not elicit reliable CBI. Experiment 3 confirmed that cerebellar tissue is significantly deeper than primary motor cortex tissue, and we provide a map of scalp-to-target distances. Conclusions: The double-cone and batwing coils designed to stimulate deeper tissue can effectively stimulate cerebellar targets. The double-cone coil was found to be most effective. The depth map provides a guide to the accessible regions of the cerebellar volume. These results can guide coil selection and stimulation parameters when designing cerebellar TMS studies. (C) 2014 The Authors. Published by Elsevier Inc.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 50 条
  • [21] Coil design considerations for deep transcranial magnetic stimulation
    Deng, Zhi-De
    Lisanby, Sarah H.
    Peterchev, Angel V.
    CLINICAL NEUROPHYSIOLOGY, 2014, 125 (06) : 1202 - 1212
  • [22] Coil design for real and sham transcranial magnetic stimulation
    Ruohonen, J
    Ollikainen, M
    Nikouline, V
    Virtanen, J
    Ilmoniemi, RJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (02) : 145 - 148
  • [23] Investigation of Coil Designs for Transcranial Magnetic Stimulation on Mice
    Rastogi, P.
    Hadimani, R. L.
    Jiles, D. C.
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (07)
  • [24] Simulation Study on Coil Design for Transcranial Magnetic Stimulation
    Hao, Dongmei
    Zhou, Yanan
    Gao, Pei
    Yang, Lin
    Yang, Yimin
    Chen, Fei
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2174 - 2177
  • [25] Coil Arrays Modeling and optimization for Transcranial Magnetic Stimulation
    Liu Jicheng
    Lu Jiqing
    Liu Cui
    Hu Yayi
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 922 - +
  • [26] Audiovisual augmentation for coil positioning in transcranial magnetic stimulation
    Schutz, Laura
    Weber, Emmanuelle
    Niu, Wally
    Daniel, Bruce
    McNab, Jennifer
    Navab, Nassir
    Leuze, Christoph
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (04): : 1158 - 1165
  • [27] Numerical investigation of biconical transcranial magnetic stimulation coil
    Wu, Y.
    Liu, Z.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,
  • [28] Design of a Dynamic Transcranial Magnetic Stimulation Coil System
    Sheng Ge
    Ruoli Jiang
    Ruimin Wang
    Ji Chen
    Journal of Medical Systems, 2014, 38
  • [29] A water-cooled transcranial magnetic stimulation coil
    Pridmore, Saxby
    Ang, Giap
    BRAIN STIMULATION, 2008, 1 (01) : 67 - 67
  • [30] Design of a Dynamic Transcranial Magnetic Stimulation Coil System
    Ge, Sheng
    Jiang, Ruoli
    Wang, Ruimin
    Chen, Ji
    JOURNAL OF MEDICAL SYSTEMS, 2014, 38 (08)