Fault Location for Interline Fault of Parallel Transmission Lines Using One-terminal Data

被引:0
|
作者
Xu, Gang [1 ]
Yu, Sheng [1 ]
Xu, Zhenyu [2 ]
机构
[1] North China Elect Power Univ, Dept Elect Engn, Beijing, Peoples R China
[2] Sifang Protect Automatizat Corp, Beijing, Peoples R China
关键词
Fault currents; fault location; interline fault; load currents; parallel transmission lines; power system faults; six-component algorithm; source impedance; transition resistance; zero-sequence mutual;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To solve the problem of Interline fault of parallel transmission lines, by means of considering the influence of zero sequence mutual inductance of parallel transmission lines a fault location algorithm based on one-terminal electrical data is proposed. Based on the analysis of the relationship of two parallel transmission lines' fault components, the fault location equation for interline fault without ground is derived by the boundary condition of interline fault mode. It is shown that the new method is independent of fault resistance, load condition and source impedance. Extensive simulation studies using PSCAD/EMTDC have verified that this approach can obtain a highly accurate fault distance, it is also proved that the proposed algorithm is independent of transition resistance, system impedance and load situation.
引用
收藏
页码:2014 / +
页数:2
相关论文
共 50 条
  • [31] Fault location of two-terminal transmission lines with a small fault resistance
    Wu, JK
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 714 - 721
  • [32] New fault location scheme for three-terminal untransposed parallel transmission lines
    Saber, Ahmed
    Emam, Ahmed
    Elghazaly, Hany
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 154 : 266 - 275
  • [33] Fault location on parallel transmission lines with series compensation
    Dutra, R
    Fabiano, L
    Saha, MM
    Lidström, S
    2004 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, 2004, : 591 - 597
  • [34] A novel one-terminal single-line-to-ground fault location algorithm in transmission line using post-single-phase-trip data
    Geng, Jianzhao
    Wang, Bin
    Dong, Xinzhou
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (16): : 184 - 193
  • [35] An accurate algorithm for fault distance estimation of two-parallel transmission line based on one-terminal sampling
    Zhang, QC
    Zhang, Y
    Song, WN
    Yu, YX
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 820 - 823
  • [36] Fault Location for Transmission Lines Using Wavelet
    de Andrade, L.
    de Leao, T. P.
    IEEE LATIN AMERICA TRANSACTIONS, 2014, 12 (06) : 1043 - 1048
  • [37] Multiple Fault Location in Three-Terminal Transmission Lines
    Ariakia, Hadi
    Emami, Kianoush
    Fernando, Tyrone
    Iu, Herbert
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 345 - 350
  • [38] Two-Terminal Fault Location on Unsymmetrical Transmission Lines
    Schulze, Roberto
    Schegner, Peter
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [39] Fault location system for multi-terminal transmission lines
    Junior G.M.
    Rodrigues E.C.N.
    Senger E.C.
    Nakagomi R.M.
    Pellini E.L.
    Controle y Automacao, 2010, 21 (02): : 201 - 213
  • [40] Novel technique for fault location estimation on parallel transmission lines using wavelet
    Jung, Hosung
    Park, Young
    Han, Moonseob
    Lee, Changmu
    Park, Hyunjune
    Shin, Myongchul
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2007, 29 (01) : 76 - 82