Feasibility of myocardial perfusion imaging studies in morbidly obese patients with a cadmium-zinc-telluride cardiac camera

被引:7
|
作者
Budzynska, Anna [1 ]
Osiecki, Sebastian [1 ]
Mazurek, Andrzej [1 ]
Piszczek, Stanistaw [1 ]
Dziuk, Mirostaw [1 ]
机构
[1] Mil Inst Med, Szaserow 128 St, PL-04141 Warsaw, Poland
关键词
obesity; BMI; myocardial perfusion imaging; CZT; cardiac camera; image artifacts; SPECT;
D O I
10.5603/NMR.2019.0003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND: A novel cardiac SPECT camera with cadmium-zinc-telluride (CZT) based technology has a fixed array of semiconductor detectors paired with pinhole collimators focused on the heart. Image acquisition in obese patients can be challenging because of much smaller detector field of view compared to conventional gamma cameras. The aim of this study was to evaluate the impact on high body mass on the feasibility of CZT myocardial perfusion imaging (MPI). The additional aim was to investigate the mechanism of the banana-shaped/obesity artifact, as referred to in literature, and to attempt at simulating it on a phantom study. MATERIAL AND METHODS: Study group consisted of 43 patients with morbid obesity (BMI >= 40 kg/m(2)). All these patients underwent myocardial perfusion imaging on both CZT cardiac camera and general purpose SPECT/CT gamma camera. Control group consisted of all patients who underwent myocardial perfusion imaging on CZT camera throughout one calendar year and whose BMI was lower than 40 kg/m(2). In this group, all repeated studies were re-analyzed for estimating the frequency of heart mispositioning in the camera field of view. The number of studies performed was 1180. A static cardiac phantom was used to simulate a banana-shaped artifact. A series of phantom acquisitions during which the phantom position was altered in the camera field of view was performed. RESULTS: In control group, 3.7% of all cardiac scintigrams required repetition, 18.9% of which were repeated due to wrong heart positioning; median BMI in this group of patients was 36.0. A banana-shaped artifact was observed in one female patient with BMI 36.0. In morbid obesity group, 32.6% of the studies were non-diagnostic with "truncation effect" on Scan Quality Control (QC). Median BMI in patients with diagnostic scans was 42.0, while in patients with not acceptable quality control test it was 45.0 (p < 0.05). Banana-shaped artifacts were observed in 5 non-diagnostic studies. In a phantom study an artifact of banana shape was obtained when gantry was distant from the phantom and target was on the edge of the camera field of view and was slightly truncated. CONCLUSIONS: Problem with heart mispositioning during imaging on the CZT camera affects less than 1% of all performed studies. Morbid obesity is not a contraindication to perform myocardial perfusion scintigraphy with the use of a CZT camera because over 2/3 of the studies of very obese patients is diagnostic.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [1] Cadmium-Zinc-Telluride Myocardial Perfusion Imaging in Obese Patients
    Fiechter, Michael
    Gebhard, Catherine
    Fuchs, Tobias A.
    Ghadri, Jelena R.
    Stehli, Julia
    Kazakauskaite, Egle
    Herzog, Bernhard A.
    Pazhenkottil, Aju P.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (09) : 1401 - 1406
  • [2] Myocardial Perfusion SPECT Imaging of Obese Patients on Cadmium Zinc Telluride (CZT) Camera
    Mallak, Nadine
    Menda, Yusuf
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [3] Feasibility of ultra low-dose thallium myocardial perfusion imaging in obese patients using cadmium-zinc-telluride scanner
    Kincl, V.
    Kaminek, M.
    Vasina, J.
    Panovsky, R.
    Havel, M.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1259 - 1259
  • [4] Radiation exposure after myocardial perfusion imaging with Cadmium-Zinc-Telluride camera versus conventional camera
    Baumgarten, Ricardo
    Cerci, Rodrigo Julio
    Costa, Amanda de Nadai
    Pereira-Neto, Carlos Cunha
    Prado, Pedro
    Zapparoli, Marcello
    Masukawa, Margaret
    Cerci, Juliano Julio
    Vitola, Joao Vicente
    Fernandes-Silva, Miguel Morita
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (03) : 992 - 999
  • [5] Radiation exposure after myocardial perfusion imaging with Cadmium-Zinc-Telluride camera versus conventional camera
    Ricardo Baumgarten
    Rodrigo Julio Cerci
    Amanda de Nadai Costa
    Carlos Cunha Pereira-Neto
    Pedro Prado
    Marcello Zapparoli
    Margaret Masukawa
    Juliano Julio Cerci
    João Vicente Vitola
    Miguel Morita Fernandes-Silva
    Journal of Nuclear Cardiology, 2021, 28 : 992 - 999
  • [6] Cadmium-Zinc-Telluride SPECT in Very Morbidly Obese Patients Routinely Provides High-Diagnostic-Quality Myocardial Perfusion Imaging REPLY
    Kaufmann, Philipp
    Gaemperli, Oliver
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (04) : 661 - 662
  • [7] Imaging of the Thyroid and Parathyroid Using a Cardiac Cadmium-Zinc-Telluride Camera: Phantom Studies
    Miyazaki, Yosuke
    Kato, Yasuhiro
    Imoto, Akira
    Fukuchi, Kazuki
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2018, 46 (01) : 39 - 44
  • [8] Myocardial perfusion imaging performed by dedicated cardiac cadmium-zinc-telluride camera in dextrocardia with situs inversus: A case report
    Lena Forsberg
    Mariana Soares
    Adrian Gonon
    Journal of Nuclear Cardiology, 2022, 29 : 3599 - 3603
  • [9] Myocardial perfusion imaging performed by dedicated cardiac cadmium-zinc-telluride camera in dextrocardia with situs inversus: A case report
    Forsberg, Lena
    Soares, Mariana
    Gonon, Adrian
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (06) : 3599 - 3603
  • [10] Simultaneous dual isotope acquisition for myocardial perfusion imaging with a cadmium-zinc-telluride camera: Preliminary study with 109 patients
    Songy, Bernard
    Flahaut, Ludovic
    Guernou, Mohamed
    Lussato, David
    Queneau, Mathieu
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53