Measurement of peripheral oxygen utilisation in neonates using near infrared spectroscopy: comparison between arterial and venous occlusion methods

被引:17
|
作者
Hassan, IAA
Spencer, SA
Wickramasinghe, YA
Palmer, KS
机构
[1] City Gen Hosp, Neonatol Unit, Stoke On Trent ST4 6QG, Staffs, England
[2] Univ Keele, Ctr Sci & Technol Med, Keele ST5 5BG, Staffs, England
关键词
near infrared spectroscopy; arterial occlusion method; venous occlusion method;
D O I
10.1016/S0378-3782(99)00076-6
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The aim of this study was to develop an arterial occlusion method and compare it with the venous occlusion method for measurement of peripheral oxygen utilisation in neonates using near infrared spectroscopy (NIRS). Twenty healthy neonates were studied. Arterial occlusion was produced by inflating a neonatal blood pressure cuff to 100 mmHg for 30-40 s and oxygen utilisation (VO2) was calculated using the HbO(2) decrement slope following occlusion. Venous occlusion was produced by inflating the cuff to 30 mmHg for 15-20 s and VO2 was calculated by: VO2 = HbT x 4 x (SaO(2)-SvO(2)), where SaO(2) is the arterial oxygen saturation measured by pulse oximetry and SvO(2) is the venous oxygen saturation measured by NIRS. Each baby had a minimum of three arterial and three venous occlusions. Criteria were developed for acceptance/rejection of an occlusion. Using the arterial method, the mean VO2 was 1.12 mM cm(-1) O-2/min (S.D. = 0.25), (95% CI = 1.00-1.24 mM cm(-1) O-2/min). The coefficient of variation was 6.6+/-4.1%. Using the venous method, the mean VO2 was 1.60 mM cm(-1) O-2/min (S.D. = 0.48), (95% CI = 1.38-1.82 mM cm(-1) O-2/min), The coefficient of variation was 12.6+/-5.7%. The correlation between the two methods was weak (r = 0.28 and r(2) was 0.08). The mean difference between the two methods was 0.47 mM cm(-1) O-2/min (S.D. = 0.51). The limits of agreement were - 0.53 to 1.47 mM cm(-1) O-2/min. The arterial method gives more consistent results. (C) Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:211 / 224
页数:14
相关论文
共 50 条
  • [21] Reproducibility of noninvasive quantitative measurement of oxygen consumption using near infrared spectroscopy
    van Beekvelt, MCP
    Colier, WNJM
    Roach, RC
    Wevers, RA
    van Engelen, BGM
    FASEB JOURNAL, 2000, 14 (04): : A315 - A315
  • [22] Abdominal Regional Oxygen Saturations Using Near-Infrared Spectroscopy in Preterm Neonates Reply
    Akinkuotu, Adesola C.
    Cruz, Stephanie M.
    Olutoye, Oluyinka O.
    PEDIATRIC CRITICAL CARE MEDICINE, 2015, 16 (02) : 201 - 202
  • [23] Comparison between noninvasive measurement of central venous pressure using near infrared spectroscopy with an invasive central venous pressure monitoring in cardiac surgical Intensive Care Unit
    Sathish, N.
    Singh, Naveen G.
    Nagaraja, P. S.
    Sarala, B. M.
    Prabhushankar, C. G.
    Dhananjaya, Manasa
    Manjunatha, N.
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (03) : 405 - 409
  • [24] Measurement of hepatic tissue hypoxia using near infrared spectroscopy: Comparison with hepatic vein oxygen partial pressure
    El-Desoky, AEH
    Jiao, LR
    Havlik, R
    Habib, N
    Davidson, BR
    Seifalian, AM
    EUROPEAN SURGICAL RESEARCH, 2000, 32 (04) : 207 - 214
  • [25] Measurement of regional forearm muscle haemodynamics via the near-infrared spectroscopy venous occlusion technique: the impact of hand circulatory occlusion
    Cross, T. J.
    van Beekvelt, M.
    Constantini, K.
    Sabapathy, S.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (12) : 2563 - 2573
  • [26] Study on Mental Stress Using Near-Infrared Spectroscopy, Electroencephalography, and Peripheral Arterial Tonometry
    Ishii, Yoshikazu
    Ogata, Hajime
    Takano, Hidenori
    Ohnishi, Hidenori
    Mukai, Toshiharu
    Yagi, Tohru
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4992 - +
  • [27] COMPARISON OF DIFFERENT TECHNIQUES OF MEASUREMENT OF QUALITATIVE PARAMETERS WITH USING NEAR INFRARED SPECTROSCOPY
    Kozelkova, M.
    Sustova, K.
    Luzova, T.
    MENDELNET 2011, 2011, : 586 - 592
  • [28] Use of near infrared spectroscopy for estimation of peripheral venous saturation in newborns: Comparison with co-oximetry of central venous blood
    Bay-Hansen, R
    Elfving, B
    Greisen, G
    BIOLOGY OF THE NEONATE, 2002, 82 (01): : 1 - 8
  • [29] Validation of cerebral venous oxygenation measured using near-infrared spectroscopy and partial jugular venous occlusion in the newborn lamb
    Wong, Flora Y.
    Barfield, Charles P.
    Campbell, Louisa
    Brodecky, Vojta A.
    Walker, Adrian M.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2008, 28 (01): : 74 - 80
  • [30] Precision of measurement of cerebral tissue oxygenation index using near-infrared spectroscopy in preterm neonates
    Sorensen, Line C.
    Greisen, Gorm
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (05)