Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity

被引:266
|
作者
Gellrich, NC
Schramm, A
Hammer, B
Rojas, S
Cufi, D
Lagrèze, W
Schmelzeisen, R
机构
[1] Univ Freiburg, Dept Oral & Maxillofacial Surg, D-79106 Freiburg, Germany
[2] Univ Freiburg, Dept Neuroophthalmol, D-79106 Freiburg, Germany
[3] Univ Basel, Dept Plast & Reconstruct Surg Oral & Maxillofacia, Basel, Switzerland
关键词
D O I
10.1097/01.PRS.0000029807.35391.E5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Until now, computer-assisted surgery has not been practiced as part of the surgical routine of posttraumatic orbital reconstruction. The purpose of this study was to investigate the use of a navigation system for computer-assisted preoperative planning with virtual reconstruction to obtain symmetry of the orbits and intraoperative control of virtual contours in comparison with the clinically achieved surgical results. A further objective of the computer-assisted orbital analysis was to use an ideal measurement for the two-dimensional and three-dimensional changes following orbital reconstruction and to check the equality of the postoperative values for the affected orbits in comparison with those of the unaffected sides. Patients with unilateral posttraumatic orbital defects (n = 18) underwent computer-assisted surgery and preoperative planning using a spiral computed tomography database. Surgical procedures were preplanned with virtual correction by mirroring an individually defined three-dimensional segment from the unaffected side onto the deformed side, creating an ideal unilateral reconstruction. These computer-models were intraoperatively used as virtual templates to navigate the preplanned contours and the globe projection using the Stryker-Leibinger navigation system. Individual noninvasive registration with an overall inaccuracy of approximately 1 mm was achieved by using a maxillary occlusal splint with four markers. The mirroring of the unaffected side allowed an ideal virtual reconstruction. A mean decrease in enlarged orbital volume of 4.0 (SD +/- 1.9) cm(3) was achieved, as was a mean increase in the sagittal globe projection of 5.88 (SD +/- 2.98) min. With a paired Student t test, the decrease between the preoperative and postoperative differences of the affected and unaffected sides was proved significant for orbital volume, globe projection, and computed tomography-based Hertel scale changes (p < 0.01). In 15 of 18 cases, simultaneous malar bone advancement resulted primarily in an additional increase in orbital volume before intraorbital augmentation with calvarial split-bone grafts could be performed. Intraorbital bony augmentation included one (n = 1), two (n = 7), three (n = 8), and all four (n = 2) orbital walls. Computer-assisted preoperative planning enables the surgeon to predict reconstructive surgical steps before the operation. Highly vulnerable structures such as the optic nerve can be detected and avoided intraoperatively, and virtually preplanned bone graft positions and/or orbital frame contours can be checked. Computer-assisted preoperative planning and surgery thus advance the difficult surgical field of orbital reconstruction, particularly through a greater exploitation of radiologic information without additional radiation to the patient.
引用
收藏
页码:1417 / 1429
页数:13
相关论文
共 50 条
  • [21] Is a computer-assisted design and computer-assisted manufacturing method for mandibular reconstruction economically viable?
    Tarsitano, Achille
    Battaglia, Salvatore
    Crimi, Salvatore
    Ciocca, Leonardo
    Scotti, Roberto
    Marchetti, Claudio
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (07) : 795 - 799
  • [22] Computer-assisted extracorporeal orbital reconstruction after optic nerve decompression by removal of sphenoid bone
    Metzger, Marc Christian
    Schoen, Ra F.
    Weyer, Nils
    Gutwald, Ralf
    Schmelzeisen, Rainer
    ANNALS OF PLASTIC SURGERY, 2006, 57 (02) : 223 - 227
  • [23] Computer-Assisted Reconstruction of an Orbital Trauma Case Treated with a Patient-Specific Titanium Prosthesis
    Darwich, Mhd Ayham
    Darwich, Khaldoun
    Yousof, Khalil
    Szavai, Szabolcs
    Nazha, Hasan Mhd
    Juhre, Daniel
    COSMETICS, 2023, 10 (02)
  • [24] Efficacy of computer-assisted training for treatment of unilateral neglect
    Webster, JS
    McFarland, PT
    Szeto-Wong, C
    Rapport, LJ
    Roades, L
    Morrill, B
    Lopez, MN
    Abadee, PS
    CLINICAL NEUROPSYCHOLOGIST, 1999, 13 (02): : 235 - 236
  • [25] Correction of a Posttraumatic Orbital Deformity Using Three-Dimensional Modeling, Virtual Surgical Planning with Computer-Assisted Design, and Three-Dimensional Printing of Custom Implants
    Day, Kristopher M.
    Phillips, Paul M.
    Sargent, Larry A.
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2018, 11 (01) : 78 - 82
  • [26] Reconstruction for diverse fronto-orbital defects with computer-assisted designed and computer-assisted manufactured PEEK implants in one-stage operation Case reports
    Yang, Min
    Wu, Zhangyi
    Yu, Hai
    Cheng, Jun
    MEDICINE, 2021, 100 (40) : E27452
  • [27] COMPUTER-ASSISTED TOMOGRAPHY - SINUS LESIONS WITH ORBITAL INVOLVEMENT
    BILANIUK, LT
    ZIMMERMAN, RA
    HEAD & NECK SURGERY, 1980, 2 (04): : 293 - 301
  • [28] COMPUTER-ASSISTED TOMOGRAPHY OF ORBITAL LESIONS IN WEGENERS GRANULOMATOSIS
    VERMESS, M
    HAYNES, BF
    FAUCI, AS
    WOLFF, SM
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (01) : 45 - 48
  • [29] COMPUTER-ASSISTED TOMOGRAPHY IN EXPERIMENTALLY INDUCED ORBITAL PSEUDOTUMOR
    WILNER, HI
    COHN, EM
    KLING, G
    JAMPEL, RS
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) : 431 - 435
  • [30] Computer-assisted system for the reconstruction of shattered objects
    Cooper, FA
    Brenningmeyer, T
    Sensors, and Command, Control, Communications, and Intelligence (C31) Technologies for Homeland Security and Homeland Defense IV, Pts 1 and 2, 2005, 5778 : 644 - 656