Voltammetric determination of trace copper(II), cadmium(II), and lead(II) using a Schiff base modified glassy carbon working electrode

被引:4
|
作者
Tahaei, Roya [1 ]
Shayani-Jam, Hassan [1 ]
Yaftian, Mohammad Reza [1 ]
机构
[1] Univ Zanjan, Fac Sci, Dept Chem, Zanjan 4537138791, Iran
来源
MONATSHEFTE FUR CHEMIE | 2021年 / 152卷 / 01期
关键词
Electrochemical sensors; Schiff base; Differential pulse anodic stripping voltammetry; Trace copper determination; Fish sample analysis; HEAVY-METAL IONS; ELECTROCHEMICAL SENSOR; WATER; PRECONCENTRATION; SILICA; CU; NANOPARTICLES; EXTRACTION; ENRICHMENT; CD2+;
D O I
10.1007/s00706-020-02730-2
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A Schiff base ligand named bis(5-bromo-2-hydroxybenzaldehyde) 1,2-propanediimine has been used to fabricate a modified glassy carbon electrode for the selective voltammetric detection of the low-level of Cu(II). The electrochemical behavior of unmodified and modified electrodes was investigated using the cyclic voltammetry technique, while the optimization of the parameters affecting the electrode characteristics and its analytical performance were evaluated by employing the differential pulse anodic stripping voltammetry. Under the optimized conditions (pH 4, decomposition time 360 s, decomposition potential vs. SCE - 1.2 V), the peak current variation as a function of the copper(II) concentration in the range of 10-100 nM was linear, with a calculated detection limit of 4.2 nM. The evaluated selectivity, reproducibility, and repeatability of the developed modified electrode showed its satisfactory performance. The ability of the prepared electrode was evaluated by its application for the analysis of Cu(II) in a fish liver tissue sample. It was confirmed also that the proposed modifie delectrode can be successfuly used for the determination of Cd(II) and Pb(II). [GRAPHICS] .
引用
收藏
页码:51 / 59
页数:9
相关论文
共 50 条
  • [41] Determination of cadmium(II) using a glassy carbon electrode modified with a Cd-ion imprinted polymer
    Dahaghin, Zohreh
    Kilmartin, Paul A.
    Mousavi, Hassan Zavvar
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 810 : 185 - 190
  • [42] Single and simultaneous voltammetric sensing of lead(II), cadmium(II) and zinc(II) using a bimetallic Hg-Bi supported on poly(1,2-diaminoanthraquinone)/glassy carbon modified electrode
    Hassan, Khalid Mahmoud
    Gaber, Seleem Elsaid
    Altahan, Mahmoud Fatehy
    Azzem, Magdi Abdel
    SENSING AND BIO-SENSING RESEARCH, 2020, 29
  • [43] High Performance of MWCNTs - Chitosan Modified Glassy Carbon Electrode for Voltammetric Trace Analysis of Cd(II)
    Solis, J. Calvillo
    Galicia, M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (07): : 6815 - 6828
  • [44] Anodic stripping voltammetric determination of copper (II) in wastewaters using a carbon paste electrode modified with chitosan
    Janegitz, Bruno Campos
    Marcolino, Luiz Humberto, Jr.
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2007, 30 (07): : 1673 - 1676
  • [45] Determination of Copper(II) ion with a nafion-ethylenediamine modified glassy carbon electrode
    Ko, Young Chun
    Kim, Hee Cheol
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2007, 20 (03): : 213 - 218
  • [46] Boron-modified Ordered Mesoporous Carbons as a novel electrode film for simultaneously Voltammetric Detection of Cadmium(II), Lead(II),Copper(II) and Mercury(II) ions
    Ye, He-Lin
    Zheng, Yan-ping
    Xue, Rui
    Xie, Yu-Long
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (03): : 1 - 15
  • [47] SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF COPPER(II), LEAD(II) AND CADMIUM(II)
    REN, SX
    GAO, L
    JOURNAL OF AUTOMATIC CHEMISTRY, 1995, 17 (03): : 115 - 118
  • [48] Simultaneous spectrophotometric determination of copper(II), lead(II) and cadmium(II)
    Ren, S.
    Gao, L.
    Journal of Automatic Chemistry, 17 (03):
  • [49] Highly sensitive simultaneous determination of cadmium (II), lead (II), copper (II), and mercury (II) ions on N-doped graphene modified electrode
    Xing, Huakun
    Xu, Jingkun
    Zhu, Xiaofei
    Duan, Xuemin
    Lu, Limin
    Wang, Wenmin
    Zhang, Youshan
    Yang, Taotao
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 52 - 58
  • [50] Amino-functionalized mesoporous silica modified glassy carbon electrode for ultra-trace copper(II) determination
    Dai, Xingxin
    Qiu, Fagui
    Zhou, Xuan
    Long, Yumei
    Li, Weifeng
    Tu, Yifeng
    ANALYTICA CHIMICA ACTA, 2014, 848 : 25 - 31