Eu-chelate construct ultrasensitive time-resolved fluoroimmunoassay-assay of pepsinogen I

被引:0
|
作者
Huang Biao [1 ]
Zhang Xiangrui
Zhu Lan
Liu Haiyan
Jiang Yehua
Jin Jian
机构
[1] Jiangsu Ist Nucl Med, Wuxi 214063, Peoples R China
[2] So Yangzi Univ, Minist Educ, Key Lab Ind Biotechnol, Wuxi 214036, Peoples R China
关键词
time-resolved fluoroimmunoassay; pepsinogen I; Eu-chelate; rare earths;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Eu-chelate were used to construct a two-site sandwich-type assay for pepsinogen I (PGI) with time-resolved fluoroinununoassay (TRFIA) as a detection technique. On the noncompetitive assay, captured monoclonal antibodies (McAbs) coated on wells were directed against a specific antigenic site on the PGI. Another McAbs, called as labeling McAbs, were prepared with the Eu-chelate of N-(p-isothiocyanatobenzyl)-diethylenetriamine-N, N, N, N-tetraacetic acid and directed against a different antigenic site on the PGI. The fluorescence counts of bound Eu3+-McAbs were measured with the auto DELFIA(1235) system. The PGI in sera from healthy volunteers were determined by PGI-TRFIA. The within-run and between-run CVs of the PGI-TRFIA were 1.9% and 4.7%, respectively, and the recovery rate was 102.65%. The assay had a detection limit of 0.05 mu g (.) L-1. The PGI-TRFIA provided a linear response from 3.5 to 328 mu g (.) L-1. The cross-reacting rate with pepsinogen II was negligible. The linear correlation of PGI-TRFIA and radioimmunassay measurements resulted in a correlation coefficient of 0.977. The means of healthy volunteers were 154 +/- 43 mu g(.)L(-1) for serum PGI. The availability of a highly sensitive, reliable, and convenient method for quantifying PGI will allow investigations into the possible diagnostic value of this analyte in various clinical conditions, including gastric carcinoma, duodenal ulcer, gastritis and severe atrophic gastritis.
引用
收藏
页码:381 / 384
页数:4
相关论文
共 50 条
  • [1] Eu-Chelate Construct Ultrasensitive Time-Resolved Fluoroimmunoassay-Assay of Pepsinogen I
    黄飚
    张祥瑞
    朱岚
    刘海燕
    蒋叶华
    金坚
    Journal of Rare Earths, 2006, (03) : 381 - 384
  • [2] Ultrasensitive detection of pepsinogen I and pepsinogen II by a time-resolved fluoroimmunoassay and its preliminary clinical applications
    Huang, B
    Xiao, HL
    Zhang, XR
    Zhu, L
    Liu, HY
    Jin, J
    ANALYTICA CHIMICA ACTA, 2006, 571 (01) : 74 - 78
  • [3] Ultrasensitive time-resolved fluoroimmunoassay of ochratoxin A
    Huang, B
    Tao, WY
    Zhang, LF
    Shi, J
    Yang, HL
    Jin, J
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2005, 32 (07) : 662 - 666
  • [4] Dual-label time-resolved fluoroimmunoassay for pepsinogen I and pepsinogen II and its preliminary application
    Zhang Jue
    Huang Biao
    Zhu Lan
    Zhang Yi
    Liu Hai-Yan
    Ma Zhi-Hong
    Guo Li-Ning
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2008, 35 (04) : 471 - 476
  • [5] Time-resolved fluoroimmunoassay of zearalenone in cereals with a europium chelate as label
    马智鸿
    黄飚
    张珏
    张艺
    朱岚
    屠蔷
    Journal of Rare Earths, 2009, 27 (06) : 1088 - 1091
  • [6] TIME-RESOLVED FLUOROIMMUNOASSAY OF CORTISOL IN SERUM WITH A EUROPIUM CHELATE AS LABEL
    DIAMANDIS, EP
    BHAYANA, V
    CONWAY, K
    REICHSTEIN, E
    PAPANASTASIOUDIAMANDIS, A
    CLINICAL BIOCHEMISTRY, 1988, 21 (05) : 291 - 296
  • [7] Time-resolved fluoroimmunoassay of zearalenone in cereals with a europium chelate as label
    Ma Zhihong
    Huang Biao
    Zhang Jue
    Zhang Yi
    Zhu Lan
    Tu Qiang
    JOURNAL OF RARE EARTHS, 2009, 27 (06) : 1088 - 1091
  • [8] Ultrasensitive time-resolved fluoroimmunoassay of aflatoxins B1
    The Key Laboratory of Industrial Biotechnology, Southern Yangtze University, Wuxi 214036, China
    不详
    He Jishu, 2006, 4 (295-300):
  • [9] Ultrasensitive Time-Resolved Fluoroimmunoassay for Saikosaponin a in Chaihu (Bupleuri Radix)
    Chao, Zhi
    Cui, Qian
    Tian, Enwei
    Zeng, Weiping
    Cai, Xuan
    Li, Xiaolei
    Tanaka, Hiroyuki
    Shoyama, Yukihiro
    Wu, Yingsong
    PLOS ONE, 2016, 11 (03):
  • [10] APPLICATION OF THE SYNERGETIC LUMINESCENCE OF EU IN TIME-RESOLVED FLUOROIMMUNOASSAY
    LI, JJ
    CHEN, GQ
    HU, JM
    ZENG, YE
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (07): : 552 - 555