Contrast-enhanced magnetic resonance angiography. Theory, technique and practical application

被引:14
|
作者
Stehling, MK
Niedermeyer, M
Laub, G
机构
[1] GESELL STRAHLENFORSCH,NEUHERBERG,GERMANY
[2] SCHERING AG,ERLANGEN,GERMANY
来源
RADIOLOGE | 1997年 / 37卷 / 07期
关键词
magnetic resonance imaging; magnetic resonance angiography; contrast agents; theory; technique;
D O I
10.1007/s001170050247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast enhanced (CE) magnetic resonance angiography affords angiographic depiction of extended Vascular territories with high quality and diagnostic value. A prerequisite is the fast acquisition of a three-dimensional gradient-echo data set during the injection of a bolus of a T1-shortening contrast agent. We describe the dependence of the quality of CE-MRA on technical parameters of different MR-scanners and consider some fundamental facts and practical guidelines concerning the contrast agent injection.
引用
收藏
页码:501 / 507
页数:9
相关论文
共 50 条
  • [31] Contrast-enhanced magnetic resonance angiography of the renal arteries - Original investigation
    Hany, TF
    Leung, DA
    Pfammatter, T
    Debatin, JF
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 653 - 659
  • [32] Pulmonary arteriovenous malformations - Diagnosis by contrast-enhanced magnetic resonance angiography
    Khalil, A
    Farres, MT
    Mangiapan, G
    Tassart, M
    Bigot, JM
    Carette, MF
    CHEST, 2000, 117 (05) : 1399 - 1403
  • [33] Contrast enhanced magnetic resonance angiography for determining patency of coronary bypass grafts. A comparison with coronary angiography.
    Wintersperger, BJ
    von Smekal, A
    Engelmann, MG
    Knez, A
    Penzkofer, HV
    Laub, G
    Reiser, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (06): : 572 - 578
  • [34] Fast contrast-enhanced magnetic resonance angiography as a replacement for conventional digital subtraction angiography
    Mohamed, A
    Meaney, J
    Robertson, I
    Homer-Vanniasinkam, SH
    Gough, MJ
    BRITISH JOURNAL OF SURGERY, 1998, 85 (05) : 705 - 705
  • [35] Feasibility of peripheral contrast-enhanced magnetic resonance angiography at 3.0 tesla with a hybrid technique - Comparison with digital subtraction angiography
    Berg, Frank
    Bangard, Christopher
    Bovenschulte, Henning
    Hellmich, Martin
    Nijenhuis, Marco
    Lackner, Klaus
    Gossmann, Axel
    INVESTIGATIVE RADIOLOGY, 2008, 43 (09) : 642 - 649
  • [36] Magnetic resonance angiography of the body in pediatric patients: experience with a contrast-enhanced time-resolved technique
    Taylor Chung
    Pediatric Radiology, 2005, 35 : 3 - 10
  • [37] Magnetic resonance angiography of the body in pediatric patients: experience with a contrast-enhanced time-resolved technique
    Chung, T
    PEDIATRIC RADIOLOGY, 2005, 35 (01) : 3 - 10
  • [38] Contrast-enhanced magnetic resonance angiography - Potential applications and pitfalls in magnetic resonance angiography-guided therapy: A review
    Schild, HH
    Kuhl, CK
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 524 - 527
  • [39] Pseudohypocalcemia after gadolinium-enhanced magnetic resonance angiography.
    Doorenbos, CJ
    Ozyilmaz, A
    Nahuis, J
    Koster, K
    van Wijnen, M
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 514A - 514A
  • [40] The future of contrast-enhanced magnetic resonance angiography -: Are blood pool agents needed?
    Mühler, A
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 709 - 714