Thermodynamic Evaluation of LiCl-H2O and LiBr-H2O Absorption Refrigeration Systems Based on a Novel Model and Algorithm

被引:33
|
作者
Ren, Jie [1 ]
Qian, Zuoqin [1 ]
Yao, Zhimin [1 ,2 ]
Gan, Nianzhong [1 ]
Zhang, Yujia [1 ]
机构
[1] Wuhan Univ Technol, Sch Energy & Power Engn, Wuhan 430063, Hubei, Peoples R China
[2] Univ Technol Sydney, Fac Engn & Informat Technol, Sydney, NSW 2007, Australia
基金
中国国家自然科学基金;
关键词
absorption refrigeration system; thermodynamic analysis; calculation model; LiCl-H2O; LiBr-H2O; off-design behaviors; DYNAMIC SIMULATION-MODEL; EXPERIMENTAL VALIDATION; PERFORMANCE EVALUATION; CHILLER PERFORMANCE; EXERGY ANALYSIS; WATER; LITHIUM; OPTIMIZATION; EQUILIBRIUM; FORMULATION;
D O I
10.3390/en12153037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An absorption refrigeration system (ARS) is an alternative to the conventional mechanical compression system for cold production. This study developed a novel calculation model using the Matlab language for the thermodynamic analysis of ARS. It was found to be reliable in LiCl-H2O and LiBr-H2O ARS simulations and the parametric study was performed in detail. Moreover, two 50 kW water-cooled single effect absorption chillers were simply designed to analyze their off-design behaviors. The results indicate that LiCl-H2O ARS had a higher coefficient of performance (COP) and exergetic efficiency, particularly in the lower generator or higher condenser temperature conditions, but it operated more restrictively due to crystallization. The off-design analyses revealed that the preponderant performance of LiCl-H2O ARS was mainly due to its better solution properties because the temperature of each component was almost the same for both chillers in the operation. The optimum inlet temperature of hot water for LiCl-H2O (83 degrees C) was lower than that of LiBr-H2O (98 degrees C). The cooling water inlet temperature should be controlled within 41 degrees C, otherwise the performances are discounted heavily. The COP and cooling capacity could be improved by increasing the temperature of hot water or chilled water properly, contrary to the exergetic efficiency.
引用
收藏
页数:28
相关论文
共 50 条
  • [41] Analysis of the minimum activation temperature of LiBr-H2O absorption chiller
    Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200240, China
    Kung Cheng Je Wu Li Hsueh Pao, 2013, 11 (2020-2024):
  • [42] Performance Test of a Small Size LiBr-H2O Absorption Chiller
    Prasartkaew, Boonrit
    11TH ECO-ENERGY AND MATERIALS SCIENCE AND ENGINEERING (11TH EMSES), 2014, 56 : 487 - 497
  • [43] Glass formation in the LiCl-H2O system
    Kirilenko, I. A.
    RUSSIAN JOURNAL OF INORGANIC CHEMISTRY, 2011, 56 (05) : 776 - 778
  • [44] Glass formation in the LiCl-H2O system
    I. A. Kirilenko
    Russian Journal of Inorganic Chemistry, 2011, 56 : 776 - 778
  • [45] Simulation Study on Solar Single/Double-Effect Switching LiBr-H2O Absorption Refrigeration System
    Li, Qingyang
    Zhao, Shiqi
    Wang, Dechang
    Song, Qinglu
    Zhou, Sai
    Wang, Xiaohe
    Li, Yanhui
    ENERGIES, 2023, 16 (07)
  • [46] Thermodynamic Modeling and Optimization of Double Effect Series flow LiBr-H2O Vapor Absorption Chiller
    Ghani, Muhammad Usman
    Zaman, Muhammad
    Khan, Imran
    2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2016,
  • [47] Thermodynamic study of a novel solar LiBr/H2O absorption chiller
    Li, Zeyu
    Jing, Yue
    Liu, Jinping
    ENERGY AND BUILDINGS, 2016, 133 : 565 - 576
  • [48] Experimental characterization of a single stage LiBr-H2O absorption test rig
    Gutierrez, G.
    Venegas, M.
    Rodriguez Aumente, P.
    Izquierdo Millan, M.
    Lecuona Neumann, A.
    ECOS 2006: PROCEEDINGS OF THE 19TH INTERNATIONAL CONFERENCE ON EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS, VOLS 1-3, 2006, : 1311 - +
  • [49] A mathematical model with experiments of single effect absorption heat pump using LiBr-H2O
    Sun, Jian
    Fu, Lin
    Zhang, Shigang
    Hou, Wei
    APPLIED THERMAL ENGINEERING, 2010, 30 (17-18) : 2753 - 2762
  • [50] A realistic approach to model LiBr-H2O smooth falling film absorption on a vertical tube
    Rogdakis, ED
    Papaefthimiou, VD
    Karampinos, DC
    APPLIED THERMAL ENGINEERING, 2003, 23 (17) : 2269 - 2283