Voltage Ride-Through Capability Verification of Wind Turbines With Fully-Rated Converters Using Reachability Analysis

被引:25
|
作者
Pico, Hugo N. Villegas [1 ]
Aliprantis, Dionysios C. [1 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
关键词
Converters; permanent magnet machines; power system faults; reachability analysis; wind power generation; COMPUTATIONAL TECHNIQUES; HYBRID;
D O I
10.1109/TEC.2013.2295168
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind turbines are required to meet grid interconnection codes for voltage ride-through, which mandate that they should not disconnect during a specified range of grid disturbances. One of the tasks of a turbine's design verification process is to ensure that it will be able to withstand any such event. This paper sets forth a powerful computational technique for design verification of Type-4 permanent-magnet synchronous generator-based turbines with fully-rated grid-side converters. The proposed method can provide assurance as to whether the currents and voltages will remain within acceptable bounds. To this end, reachability theory is employed to find sets that enclose all possible trajectories for the system states caused by a given set of unknown-but-bounded disturbances. The computation of the reachable sets is carried out by using on-the-fly linearization of the nonlinear system dynamics, zonotopes, and interval analysis.
引用
收藏
页码:392 / 405
页数:14
相关论文
共 50 条
  • [11] Low voltage ride-through capability for wind turbines based on current source inverter topologies
    Tenca, Pierluigi
    Rockhill, Andrew A.
    Lipo, Thomas A.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 1308 - +
  • [12] Fault analysis of doubly fed induction generator wind turbines with low-voltage ride-through capability
    Bi, Tian-Shu
    Liu Su-Mei
    Xue, An-Cheng
    Yang, Qi-Xun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2013, 41 (02): : 26 - 31
  • [13] A Fuzzy Controller for Improving Fault Ride-Through Capability of Wind Turbines
    Mokryani, Geev
    Siano, Pierluigi
    Piccolo, Antonio
    Calderaro, Vito
    2011 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2011,
  • [14] A Cut-Out Strategy for Wind Turbines that Ensures Low-Voltage Ride-Through Capability
    Aiguo Tan
    Zhihan Tang
    Xianbo Sun
    Jianwei Zhong
    Honghua Liao
    Haibing Fang
    Journal of Electrical Engineering & Technology, 2020, 15 : 1567 - 1575
  • [15] A Cut-Out Strategy for Wind Turbines that Ensures Low-Voltage Ride-Through Capability
    Tan, Aiguo
    Tang, Zhihan
    Sun, Xianbo
    Zhong, Jianwei
    Liao, Honghua
    Fang, Haibing
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (04) : 1567 - 1575
  • [16] Improvement of the Low-voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines
    Ling, Yu
    Dou, Zhenlan
    Gao, Qiang
    Cai, Xu
    WIND ENGINEERING, 2012, 36 (05) : 535 - 551
  • [17] High Voltage Ride-Through of DFIG-based Wind Turbines
    Feltes, C.
    Engelhardt, S.
    Kretschmann, J.
    Fortmann, J.
    Koch, F.
    Erlich, I.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 1477 - 1484
  • [18] Voltage booster scheme for enhancing the fault ride-through of wind turbines
    Goweily, Khaled
    El Moursi, Mohamed Shawky
    Abdel-Rahman, Mohamed
    Badr, Mohamed A. L.
    IET POWER ELECTRONICS, 2015, 8 (10) : 1853 - 1863
  • [19] Enhancement of the Dynamic Behavior of the Low Voltage Ride-Through Wind Turbines
    Saidi, Abdelaziz Salah
    Helmy, Walid
    2018 9TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2018,
  • [20] Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips
    Rahimi, Mohsen
    Parniani, Mostafa