Diagnosis of Pseudopregnancy in a Beetal Goat Using Real-Time B-Mode Ultrasonography

被引:0
|
作者
Khan, Muhammad Irfan-ur-Rehman [1 ]
Channa, Aijaz Ali [1 ]
Sattar, Abdul [1 ]
机构
[1] Univ Vet & Anim Sci, Dept Theriogenol, Lahore 54000, Pakistan
关键词
Beetal goat; Hydrometra; Ovary; Pseudopregnancy; Ultrasonography; Uterus; DAIRY GOATS; HYDROMETRA; ETIOLOGY;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A four-year old Beetal goat was presented for early pregnancy diagnosis 30-days post-breeding. The goat was healthy and showed distended abdomen. Two ultrasound examinations of the reproductive tract were performed on 30th and 60th-day post-breeding, using 3.5 MHz convex and/or 7.5 MHz linear array transducers to diagnose pregnancy. On 30th and 60th day post-breeding, uterus appeared thin-walled, compartmentalized and filled with clear, anechoic fluid; without the presence of any fetus or placentome. On 60th day post-breeding, transrectal scanning (7.5 MHz) revealed two large (5-6 mm) and a small follicle (2-3 mm) along with a corpus luteum (8 mm) on the right ovary. Based on the characteristic ultrasound images of the uterus and ovary, pseudopregnancy was diagnosed in the Beetal goat. (C) 2015 PVJ. All rights reserved
引用
收藏
页码:537 / 539
页数:3
相关论文
共 50 条
  • [21] B-MODE ULTRASONOGRAPHY IN THE DIAGNOSIS OF PERITONSILLAR ABSCESS
    MOSGES, R
    SCHLONDORFF, G
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1988, 245 (06): : 377 - 377
  • [22] EFFICACY OF REAL-TIME B-MODE ULTRASONOGRAPHY VERSUS IMPEDANCE PLETHYSMOGRAPHY IN THE DIAGNOSIS OF DEEP-VEIN THROMBOSIS IN SYMPTOMATIC OUTPATIENTS
    HEIJBOER, H
    BRANDJES, DPM
    LENSING, AWA
    BULLER, HR
    TENCATE, JW
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 804 - 804
  • [23] DIAGNOSTIC-ACCURACY OF REAL-TIME B-MODE ULTRASONOGRAPHY IN THE DIAGNOSIS OF NON-SYMPTOMATIC DEEP-VEIN THROMBOSIS
    BORRIS, LC
    LASSEN, MR
    CHRISTIANSEN, HM
    OLSEN, AD
    SCHOTT, P
    THROMBOSIS AND HAEMOSTASIS, 1989, 62 (01) : 278 - 278
  • [24] ACCURACY OF REAL-TIME B-MODE ULTRASONOGRAPHY IN THE DIAGNOSIS OF ASYMPTOMATIC DEEP-VEIN THROMBOSIS IN HIP-SURGERY PATIENTS
    AGNELLI, G
    VOLPATO, R
    RADICCHIA, S
    LUPATTELLI, L
    RINONAPOLI, E
    NENCI, GG
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1175 - 1175
  • [25] REAL-TIME B-MODE ULTRASONOGRAPHY IN THE DETECTION OF EXTRA-CRANIAL CAROTID VASCULAR-DISEASE
    BURNS, RP
    RUSSELL, WL
    CLEMENTS, JB
    COFER, JB
    SOUTHERN MEDICAL JOURNAL, 1983, 76 (09) : P71 - P71
  • [26] NEUROLOGIC SYMPTOMS ASSOCIATED WITH NONOBSTRUCTIVE PLAQUE AT CAROTID BIFURCATION - ANALYSIS BY REAL-TIME B-MODE ULTRASONOGRAPHY
    WEINBERGER, J
    ROBBINS, A
    ARCHIVES OF NEUROLOGY, 1983, 40 (08) : 489 - 492
  • [27] HIGHLY ACCURATE DETECTION OF DEEP-VEIN THROMBOSIS (DVT) BY REAL-TIME B-MODE ULTRASONOGRAPHY
    LENSING, AWA
    PRANDONI, P
    BRANDJES, D
    HUISMAN, PM
    VIGO, M
    TOMASELLA, G
    KREKT, J
    TENCATE, JW
    HUISMAN, MV
    BULLER, HR
    THROMBOSIS AND HAEMOSTASIS, 1989, 62 (01) : 335 - 335
  • [28] Real-time B-mode ultrasound in the ED saves time in the diagnosis of deep vein thrombosis (DVT)
    Theodoro, D
    Blaivas, M
    Duggal, S
    Snyder, G
    Lucas, M
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2004, 22 (03): : 197 - 200
  • [29] STATIC AND REAL-TIME B-MODE SONOGRAPHY OF ARTERIAL OCCLUSIONS
    GOODING, GAW
    EFFENEY, DJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (05) : 949 - 952
  • [30] Characterization of carotid artery plaques using real-time compound B-mode ultrasound
    Kern, R
    Szabo, K
    Hennerici, M
    Meairs, S
    STROKE, 2004, 35 (04) : 870 - 875