Early Contrast-Enhanced Magnetic Resonance Imaging with Fluid-Attenuated Inversion Recovery in Multiple Sclerosis

被引:4
|
作者
Kataoka, Hiroshi [1 ]
Taoka, Toshiaki [2 ]
Ueno, Satoshi [1 ]
机构
[1] Nara Med Univ, Dept Neurol, Nara 6348522, Japan
[2] Nara Med Univ, Dept Radiol, Nara 6348522, Japan
关键词
Multiple sclerosis; FLAIR; contrast MRI; SUBARACHNOID HEMORRHAGE; SIGNAL-INTENSITY; PULSE SEQUENCES; FLAIR IMAGES; MR; BRAIN; CHILDREN; DISEASE; LESIONS; CSF;
D O I
10.1111/j.1552-6569.2008.00315.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Contrast-enhanced magnetic resonance imaging (MRI) with fluid-attenuated inversion recovery (contrast FLAIR) is particularly useful for the detection of meningeal lesions. However, whether contrast FLAIR is useful in multiple sclerosis (MS) remains uncertain. This study evaluated the usefulness of contrast FLAIR in MS. PATIENTS AND METHODS We prospectively studied the clinical histories and brain MRI studies of 6 patients with clinically definite MS diagnosed according to the new McDonald criteria. Contrast FLAIR (repetition time [TR] 9,000 ms; echo time [TE] 120 ms; inversion time [TI] 2,200 ms; 5-mm slice thickness, with a 1-mm interslice gap) was obtained with the use of a bolus of gadolinium diethylenetriamine pentaacetic acid. RESULTS Three enhancing plaques located in the periventricular or juxtacortical areas showed higher intensity on contrast FLAIR than on other MR sequences. In contrast, 8 enhancing plaques in the deep white matter or infratentorial areas showed no increased signals on contrast FLAIR. CONCLUSION Our findings suggest that early contrast-enhanced imaging with FLAIR may be helpful for the further detection of MS plaques, particularly those located in periventricular and juxtacortical lesions. J Neuroimaging 2009;19:246-249.
引用
收藏
页码:246 / 249
页数:4
相关论文
共 50 条
  • [31] Fluid-attenuated inversion-recovery SSFP imaging
    Bangerter, Neal K.
    Hargreaves, Brian A.
    Gold, Garry E.
    Stucker, Daniel T.
    Nishimura, Dwight G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 1426 - 1431
  • [32] Optimization of Contrast Agent Dosage on Contrast-Enhanced T2 Fluid-Attenuated Inversion Recovery: An In Vitro and In Vivo Study
    Rui, Wenting
    Jin, Teng
    Zhang, Hua
    Wang, Jing
    Ren, Yan
    Wu, Shiman
    Bai, Jing
    Zhang, Junhai
    Yao, Zhenwei
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (01) : 121 - 127
  • [33] Contrast-Enhanced Three-Dimensional Fluid-Attenuated Inversion Recovery Imaging with an Optimal Scan Interval and Angulation to Visualize Endolymphatic Hydrops
    Li, Jinye
    Sun, Lixin
    Wang, Linsheng
    Hu, Na
    Li, Long
    Song, Gesheng
    Xu, Han
    Xu, Ting
    Dou, Weiqiang
    Gong, Ruozhen
    Li, Chuanting
    IRANIAN JOURNAL OF RADIOLOGY, 2022, 19 (03)
  • [34] Association of audiovestibular findings with fluid-attenuated inversion recovery magnetic resonance imaging in patients with vestibular schwannoma
    Lee, Se A.
    Hong, Hyun Sook
    Lee, Jong Dae
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2024, 244
  • [35] Image fusion of fluid-attenuated inversion recovery magnetic resonance imaging sequences for surgical image guidance
    Mascott, Christopher R.
    Summers, Lori E.
    SURGICAL NEUROLOGY, 2007, 67 (06): : 589 - 603
  • [36] Imaging finding and analysis of brain lymphoma in contrast-enhanced fluid attenuated inversion recovery sequence
    Lee, Yoon Chul
    Suh, Sangil
    Ryoo, Inseon
    Jung, Hyena
    Joo, Leehi
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [37] Comparative between Double Inversion Recovery and Fluid-Attenuated Inversion Recovery Sequences for Detection of Brain Multiple Sclerosis
    Elhussein, Nagwan
    Alazmi, Norah
    Fadulemulla, Ibtisam Abdallah
    Hamd, Zuhal Yassin
    Ahmed, Amna Mohamed
    Seifeldin, Sara A.
    Alshammari, Qurain Turki
    CLINICAL CANCER INVESTIGATION JOURNAL, 2022, 11 (06): : 41 - 44
  • [38] Abrogation of fluid suppression in intracranial postcontrast fluid-attenuated inversion recovery magnetic resonance imaging: A clinical and phantom study
    Dickinson, Peter J.
    Jones-Woods, Sarah
    Cissell, Derek D.
    VETERINARY RADIOLOGY & ULTRASOUND, 2018, 59 (04) : 432 - 443
  • [39] The Hyperintense Acute Reperfusion Marker on Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Is Caused by Gadolinium in the Cerebrospinal Fluid
    Koehrmann, Martin
    Struffert, Tobias
    Frenzel, Thomas
    Schwab, Stefan
    Doerfler, Arnd
    STROKE, 2012, 43 (01) : 259 - 261
  • [40] Fluid-Attenuated Inversion Recovery Sequence with Fat Suppression for Assessment of Ankle Synovitis without Contrast Enhancement: Comparison with Contrast-Enhanced MRI
    Kang, Ji Hee
    Moon, Sung Gyu
    Jung, Hong-Geun
    Kwon, Eun Young