Transmissive dark-field illumination method for high-accuracy automatic lace scalloping

被引:6
|
作者
Bamforth, P. E. [1 ]
Jackson, M. R. [1 ]
Williams, K. [1 ]
机构
[1] Loughborough Univ Technol, Dept Mech & Mfg Engn, Mechatron Res Grp, Loughborough LE11 3TU, Leics, England
关键词
decorative lace; machine vision; LED illumination; CO(2) laser;
D O I
10.1007/s00170-005-0359-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A vision system has been developed to facilitate the pulsed-laser cutting of decorative lace used in various forms of apparel. Existing vision systems for lace cutting utilise back-lighting or top-lighting techniques to create a near-binary image of the lace. This can lead to problems in identifying the lace cutting path accurately. A transmissive illumination system has been modelled and tested that can reveal density information from the lace, and so, provide a more suitable image for identifying cutting points on the lace web. Experimental results have demonstrated that the illumination method can be successfully modelled to ensure even illumination using light emitting diodes (LED).
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [41] A simple method of dark field illumination
    Kronberger, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1919, 45 : 662 - 663
  • [42] Automatic shaping of high-accuracy aspheric surfaces
    Gorshkov, VA
    Papaev, AY
    Podobryanskii, AV
    JOURNAL OF OPTICAL TECHNOLOGY, 2004, 71 (12) : 807 - 811
  • [43] DARK-FIELD ILLUMINATION IMPROVES MICROSCOPIC DETECTION OF METALS IN TIMMS STAINED TISSUE
    BAATRUP, E
    FREDERICKSON, CJ
    HISTOCHEMICAL JOURNAL, 1989, 21 (08): : 477 - &
  • [44] X-ray Dark-Field Tomography Using Edge-Illumination
    Doherty, Adam
    Savidis, Savvis
    Astolfo, Alberto
    Massimi, Lorenzo
    Djurabekova, Nargiza
    Navarrete-Leon, Carlos
    Gerli, Mattia F. M.
    Iacoviello, Francesco
    Shearing, Paul R.
    Norman, Danielle G.
    Williams, Mark A.
    Olivo, Alessandro
    Endrizzi, Marco
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [45] Hard X-ray dark-field imaging with incoherent sample illumination
    Endrizzi, Marco
    Diemoz, Paul C.
    Millard, Thomas P.
    Jones, J. Louise
    Speller, Robert D.
    Robinson, Ian K.
    Olivo, Alessandro
    APPLIED PHYSICS LETTERS, 2014, 104 (02)
  • [46] Wavelength-Resolved Flow Cytometer Under a Dark-Field Illumination Configuration
    Lin, Shi-Wei
    Wang, Pin-Yao
    Chen, Angela
    Chang, Chih-Han
    Lin, Che-Hsin
    IEEE SENSORS JOURNAL, 2011, 11 (11) : 2845 - 2851
  • [47] A method of laser dark-field illumination for equal-probability excitation and photobleaching of randomly oriented fluorescent molecules
    Klimov A.A.
    Klimov D.A.
    Biophysics, 2009, 54 (5) : 661 - 666
  • [48] SIMPLE METHOD FOR DIRECT DARK-FIELD AGAR MICROSCOPY
    ORSKOV, J
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA, 1950, 27 (05): : 765 - 766
  • [49] A high-accuracy composite grid method
    Volkov, EA
    Dosiyev, AA
    Bozer, M
    DOKLADY MATHEMATICS, 2004, 69 (03) : 391 - 393
  • [50] Automatic, high-accuracy image registration in confocal microscopy
    Liu, Jian
    Li, Yong
    Wang, Weibo
    Wang, Yuhang
    Zhang, He
    Tan, Jiubin
    APPLIED OPTICS, 2017, 56 (32) : 8924 - 8930