Fast 32-channel readout chip with counters for GEMs, APDs and MGCs

被引:0
|
作者
Hollander, RW [1 ]
van Eijk, WE [1 ]
Huizenga, J [1 ]
Lubking, GW [1 ]
de Gans, D [1 ]
Schelen, JBJ [1 ]
机构
[1] Delft Univ Technol, Inst Interfac Reactor, Radiat Technol Dept, NL-2629 JB Delft, Netherlands
关键词
D O I
10.1109/NSSMIC.2001.1009677
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
New bright radiation sources like the new generation spallation sources, require fast detectors and fast readout electronics. Position sensitive detectors for imaging applications will be segmented and data rates of 10(7) s(-1) per readout channel are envisaged. We are developing a 32-channel self triggering fast readout chip, with two 24-bit 100 MHz counters per channel. Per chip one calibration input, the analog output of one selectable channel and the common OR-ed comparator output are available for testing and calibration. The common comparator threshold is set on chip with a DAC. Noisy channels can be disabled. Two counters per channel are implemented for off-line correction of 2-channel clusters. Most parts of the chip are tested and some are available as separate chips. On the 8 channel preamplifier-shaper chip for each channel a 50 Omega output buffer has been added. Rise and fall times of 2.4 ns and 7.6 ns respectively have been obtained.
引用
收藏
页码:797 / 799
页数:3
相关论文
共 24 条
  • [21] Design of a 12-bit 1 MS/s SAR-ADC for front-end readout of 32-channel CZT detector imaging syst em
    Liu, Wei
    Wei, Tingcun
    Li, Bo
    Guo, Panjie
    Hu, Yongcai
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 786 : 155 - 163
  • [22] A Single-Chip 32-Channel Analog Beamformer With 4-ns Delay Resolution and 768-ns Maximum Delay Range for Ultrasound Medical Imaging With a Linear Array Transducer
    Um, Ji-Yong
    Kim, Yoon-Jee
    Cho, Seong-Eun
    Chae, Min-Kyun
    Kim, Byungsub
    Sim, Jae-Yoon
    Park, Hong-June
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2015, 9 (01) : 138 - 151
  • [23] Diffusion Weighted Imaging A Comprehensive Evaluation of a Fast Spin Echo DWI Sequence With BLADE (PROPELLER) k-Space Sampling at 3 T, Using a 32-Channel Head Coil in Acute Brain Ischemia
    Attenberger, Ulrike I.
    Runge, Val M.
    Stemmer, Alto
    Williams, Kenneth D.
    Naul, L. Gill
    Michaely, Henrik J.
    Schoenberg, Stefan O.
    Reiser, Maximilian F.
    Wintersperger, Bernd J.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (10) : 656 - 661
  • [24] VFAT2: A front-end "system on chip" providing fast trigger information and digitized data storage for the charge sensitive readout of multi-channel silicon and gas particle detectors.
    Aspell, P.
    Anelli, G.
    Chalmet, P.
    Kaplon, J.
    Kloukinas, K.
    Mugnier, H.
    Snoeys, W.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 764 - +