Development and implementation of a simple digitizer for morphometry

被引:0
|
作者
Kao, SD [1 ]
Cheng, YP [1 ]
Tai, YY [1 ]
Jan, GJ [1 ]
机构
[1] NATL TAIWAN UNIV, DEPT ELECT ENGN, TAIPEI 10764, TAIWAN
关键词
D O I
10.1088/0957-0233/7/8/015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple digitizer with utilizes a piece of touch panel position sensor (TPPS) material and a homemade control board has been developed for semi-automatic quantitative morphometry. The profile areas were digitized by tracing with a freehand drawing and the raw data were then stored in a personal computer (PC) for further processing. This is an extremely useful tool for digitizing and converting graphic data from previously published data for comparison and/or processing of new physical parameters. Sequential architecture of hardware and software components for control and data acquisition are described and discussed in this paper. The resolution and accuracy of this PC-based digitizer are also characterized and discussed.
引用
收藏
页码:1182 / 1186
页数:5
相关论文
共 50 条
  • [31] DEVELOPMENT MORPHOMETRY OF THE VAGUS NERVE IN THE OPOSSUM
    KROUS, HF
    JORDAN, J
    WEN, J
    FARBER, JP
    DEVELOPMENTAL BRAIN RESEARCH, 1985, 20 (01): : 155 - 159
  • [32] Development, implementation and impact of simple patient safety interventions in a university teaching hospital
    Hofmeister, Erik H.
    Quandt, Jane
    Braun, Christina
    Shepard, Molly
    VETERINARY ANAESTHESIA AND ANALGESIA, 2014, 41 (03) : 243 - 248
  • [33] Development of an Ethernet-Enabled Digitizer for On-Site AC Measurements
    Wright, Paul S.
    Clarkson, Paul
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) : 2229 - 2234
  • [34] OPTIC DISK MORPHOMETRY IN SIMPLE OPTIC-NERVE ATROPHY
    JONAS, JB
    NGUYEN, NX
    NAUMANN, GOH
    ACTA OPHTHALMOLOGICA, 1989, 67 (02): : 199 - 203
  • [35] Advances in morphometry of soil macroporosity through simple techniques of mathematics
    Sampaio, E. P.
    Sampaio, J. M.
    INTERNATIONAL AGROPHYSICS, 2010, 24 (03) : 303 - 311
  • [36] A Simple Digitizer for GMR-Based Magnetic Field Sensor With Some Key Practical Considerations
    Saha, Shouvik
    Nandapurkar, Kishor Bhaskarrao
    IEEE SENSORS JOURNAL, 2024, 24 (10) : 16290 - 16298
  • [37] Development of a computational tool for myelinated fibre morphometry
    Novas, R.
    Silva, A. R.
    Fazan, V. P.
    Felipe, J.
    JOURNAL OF NEUROLOGY, 2012, 259 : S127 - S127
  • [38] MORPHOMETRY OF POSTNATAL-DEVELOPMENT IN THE PORCINE LUNG
    WINKLER, GC
    CHEVILLE, NF
    ANATOMICAL RECORD, 1985, 211 (04): : 427 - 433
  • [39] MORPHOMETRY OF THE AUDITIVE OSSICLES IN HUMAN AT THE CONCEPTION DEVELOPMENT
    OLSZEWSKI, J
    ANATOMISCHER ANZEIGER, 1990, 171 (03): : 187 - 191
  • [40] MORPHOMETRY OF PECTORAL DEVELOPMENT IN TURKEY BREEDING STOCK
    SWATLAND, HJ
    BRITISH POULTRY SCIENCE, 1989, 30 (04) : 785 - 795