Assessment of Prosthesis Alignment after Revision Total Knee Arthroplasty Using EOS 2D and 3D Imaging: A Reliability Study

被引:26
|
作者
Meijer, Marrigje F. [1 ]
Boerboom, Alexander L. [1 ]
Stevens, Martin [1 ]
Bulstra, Sjoerd K. [1 ]
Reininga, Inge H. F. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Orthopaed, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Trauma Surg, Groningen, Netherlands
来源
PLOS ONE | 2014年 / 9卷 / 09期
关键词
LOWER-EXTREMITY; REPRODUCIBILITY; REHABILITATION; AGREEMENT; POSITION; ROTATION; SYSTEM;
D O I
10.1371/journal.pone.0104613
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA). Methods: Forty anteroposterior and lateral images of 37 rTKA patients were included. Two observers independently performed measurements on these images twice. Varus/valgus angles were measured in 2D (VV2D) and 3D (VV3D). Intraclass correlation coefficients and the Bland and Altman method were used to determine reliability. T-tests were used to test potential differences. Results: Intraobserver and interobserver reliability were excellent for VV2D and VV3D. No significant difference or bias between the first and second measurements or the two observers was found. A significant mean and absolute difference of respectively 1.00 degrees and 1.61 degrees existed between 2D and 3D measurements. Conclusions: EOS provides reliable varus/valgus measurements in 2D and 3D for the alignment of the knee joint with a knee prosthesis. However, significant differences exist between varus/valgus measurements in 2D and 3D.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Comparing 2D and 3D Imaging
    Ballantyne, Lauren
    JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (03) : 138 - 141
  • [22] Novel exploration of customized 3D printed shoulder prosthesis in revision of total shoulder arthroplasty A case report
    Zou, Yun
    Yang, Yingying
    Han, Qing
    Yang, Kerong
    Zhang, Kesong
    Wang, Jincheng
    Zou, Yongwei
    MEDICINE, 2018, 97 (47)
  • [23] An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements
    Hideki Ueyama
    Yukihide Minoda
    Ryo Sugama
    Yoichi Ohta
    Kazumasa Yamamura
    Suguru Nakamura
    Susumu Takemura
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1580 - 1586
  • [24] An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements
    Ueyama, Hideki
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Yamamura, Kazumasa
    Nakamura, Suguru
    Takemura, Susumu
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) : 1580 - 1586
  • [25] Alignment of multimodality, 2D and 3D breast images
    Grevera, GJ
    Udupa, JK
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1135 - 1143
  • [26] 3D strain imaging using a rectilinear 2D array
    Awad, Samer I.
    Yen, Jesse T.
    ULTRASONIC IMAGING, 2007, 29 (04) : 220 - 230
  • [27] Fast alignment of 3D geometrical models and 2D grayscale images using 2D distance maps
    Iwashita, Yumi
    Kurazume, Ryo
    Konishi, Kozo
    Nakamoto, Masahiko
    Hashizume, Makoto
    Hasegawa, Tsutomu
    Systems and Computers in Japan, 2007, 38 (14): : 52 - 62
  • [28] Fast alignment of 3D geometrical models and 2D color images using 2D distance maps
    Iwashita, Y
    Kurazume, R
    Hasegawa, T
    Hara, K
    FIFTH INTERNATIONAL CONFERENCE ON 3-D DIGITAL IMAGING AND MODELING, PROCEEDINGS, 2005, : 164 - 171
  • [29] Accuracy of 2D CT-Based Measurements of Rotational Alignment of the Femoral Component for Total Knee Arthroplasty
    Park, Jun Young
    Kwon, Hyuck Min
    Cho, Byung Woo
    Lee, Woo-Suk
    Yang, Ick Hwan
    Park, Kwan Kyu
    YONSEI MEDICAL JOURNAL, 2021, 62 (05) : 439 - 445
  • [30] EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation
    McKenna, C.
    Wade, R.
    Faria, R.
    Yang, H.
    Stirk, L.
    Gummerson, N.
    Sculpher, M.
    Woolacott, N.
    HEALTH TECHNOLOGY ASSESSMENT, 2012, 16 (14) : 1 - +