Experimental Evaluation of a New Antithrombogenic Stent Using Ion Beam Surface Modification

被引:6
|
作者
Sugita, Yoichi [1 ,2 ,3 ]
Suzuki, Yoshiaki [4 ]
Someya, Kenji [4 ]
Ogawa, Akira [5 ]
Furuhata, Hiroshi [2 ]
Miyoshi, Shinichiro [3 ]
Motomura, Tadashi
Miyamoto, Hiroshi
Igo, Stephen
Nose, Yukihiko
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[2] Jikei Univ, Sch Med, Tokyo, Japan
[3] Dokkyo Univ, Sch Med, Mibu, Tochigi, Japan
[4] RIKEN, Saitama, Japan
[5] ACTMENT Co Ltd, Saitama, Japan
关键词
Coronary stent; Cerebral stent; Ion beam surface modification; Neointima; Collagen; DRUG-ELUTING STENTS; PLASMA-PROTEIN ADSORPTION; SELF-EXPANDING STENTS; CELL ATTACHMENT; CLINICAL-OUTCOMES; LATE THROMBOSIS; ADHESION; COLLAGEN; IMPLANTATION; ARTERY;
D O I
10.1111/j.1525-1594.2009.00747.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new antithrombogenic stent using ion beam surface modification nanotechnology was evaluated. The ion stent is being developed to inhibit acute and chronic stent-related thrombosis. Thirty self-expanding mesh stents were fabricated from Ti-Ni metal wires with a dimension of 4 mm (diameter) x 25 mm (length) x 0.15 mm (thickness). Twenty stents were coated with type I collagen and irradiated with a He+ ion beam at an energy of 150 keV with fluences of 1 x 10(14) ions/cm(2) (ion stent group). Ten stents had no treatment (non-ion stent group). The self-expanding stents were implanted into the right and left peripheral femoral arteries of 15 beagle dogs (vessel diameter approximately 3 mm) via a 6Fr catheter under fluoroscopic guidance. Heparin (100 units/kg) was administered intravenously before implantation. Following stent implantation, no antiplatelet or anticoagulant drugs were administered. The 1-month patency rate for the non-ion stent group was 10% (1/10), and for the ion stent group it was 80% (16/20) with no anticoagulant or antiplatelet drugs given after stent implantation (P = 0.0004 by Fisher's exact test). Ten stents remain patent after 2 years in vivo with no anticoagulant or antiplatelet drugs. These results indicate that He+ ion-implanted collagen-coated Ti-Ni self-expanding stents have excellent antithrombogenicity and biocompatibility. This ion stent is promising for coronary and cerebral stent applications.
引用
收藏
页码:456 / 463
页数:8
相关论文
共 50 条
  • [41] Development of liquid polyatomic ion beam system for surface modification
    Takaoka, Gikan H.
    Tsumura, Kazumichi
    Yamamoto, Tomoaki
    Japanese Journal of Applied Physics, Part 2: Letters, 2002, 41 (6 A):
  • [42] Mechanisms of argon ion-beam surface modification of polystyrene
    Zekonyte, J
    Erichsen, J
    Zaporojtchenko, V
    Faupel, F
    SURFACE SCIENCE, 2003, 532 : 1040 - 1044
  • [43] Surface modification of PEEK with gas cluster ion beam irradiation
    Uozumi, Yuki
    Toyoda, Noriaki
    Yamada, Isao
    2016 21ST INTERNATIONAL CONFERENCE ON ION IMPLANTATION TECHNOLOGY (IIT), 2016,
  • [44] Ion-beam modification of stainless steel surface roughness
    Wilk, J
    Kowalski, ZW
    NUKLEONIKA, 1999, 44 (02) : 265 - 270
  • [45] Development of liquid polyatomic ion beam system for surface modification
    Takaoka, GH
    Tsumura, K
    Yamamoto, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2002, 41 (6A): : L660 - L662
  • [46] Modification the surface properties of polyethylene by high energy ion beam
    El-Gendy, Y. A.
    Kelany, A.
    Abdul-Kader, A. M.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 162 : 12 - 17
  • [47] Ion beam modification of surface properties of CR-39
    Abdul-Kader, A. M.
    El-Badry, Basma A.
    Zaki, M. F.
    Hegazy, Tarek M.
    Hashem, Hany M.
    PHILOSOPHICAL MAGAZINE, 2010, 90 (19) : 2543 - 2555
  • [48] Thin film growth and surface modification by keV ion beam
    Choi, SC
    Park, YW
    Choi, WK
    Kim, KH
    Cho, JS
    Han, S
    Cho, J
    Jung, S
    Han, YG
    Yoo, BK
    Jung, HJ
    Koh, SK
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1998, 37 (12B): : 6984 - 6990
  • [49] THE MICHIGAN-ION-BEAM-LABORATORY FOR SURFACE MODIFICATION AND ANALYSIS
    WAS, GS
    ROTBERG, VH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 : 722 - 726
  • [50] A MECHANISTIC VIEW OF ION-BEAM INDUCED SURFACE MODIFICATION
    WIEDERSICH, H
    JOURNAL OF METALS, 1980, 32 (12): : 20 - 20