Reduction of noise in the neonatal intensive care unit using sound-activated noise meters

被引:24
|
作者
Wang, D. [1 ]
Aubertin, C. [1 ]
Barrowman, N. [2 ]
Moreau, K. [2 ]
Dunn, S. [1 ,3 ]
Harrold, J. [1 ,2 ,3 ]
机构
[1] Childrens Hosp Eastern Ontario, Ottawa, ON K1H 8L1, Canada
[2] Childrens Hosp Eastern Ontario, Res Inst, Ottawa, ON K1H 8L1, Canada
[3] Univ Ottawa, Ottawa, ON, Canada
关键词
D O I
10.1136/archdischild-2014-306490
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives To determine if sound-activated noise meters providing direct audit and visual feedback can reduce sound levels in a level 3 neonatal intensive care unit (NICU). Design/methods Sound levels (in dB) were compared between a 2-month period with noise meters present but without visual signal fluctuation and a subsequent 2 months with the noise meters providing direct audit and visual feedback. Results There was a significant increase in the percentage of time the sound level in the NICU was below 50 dB across all patient care areas (9.9%, 8.9% and 7.3%). This improvement was not observed in the desk area where there are no admitted patients. There was no change in the percentage of time the NICU was below 45 or 55 dB. Conclusions Sound-activated noise meters seem effective in reducing sound levels in patient care areas. Conversations may have moved to non-patient care areas preventing a similar change there.
引用
收藏
页码:F515 / F516
页数:2
相关论文
共 50 条
  • [21] The impact of a noise reduction quality improvement project upon sound levels in the open-unit-design neonatal intensive care unit
    Liu, W. F.
    JOURNAL OF PERINATOLOGY, 2010, 30 (07) : 489 - 496
  • [22] The impact of a noise reduction quality improvement project upon sound levels in the open-unit-design neonatal intensive care unit
    W F Liu
    Journal of Perinatology, 2010, 30 : 489 - 496
  • [23] Be Quiet! You Are Getting On My Neurons! Noise Reduction in the Neonatal Intensive Care Unit
    Notestine, Jennifer L.
    Rapp, Teresa L.
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2012, 41 : S42 - S42
  • [24] Noise exposure in a neonatal intensive care unit Is there a day-night difference in sound exposure?
    Backhaus, C.
    Carl, A.
    Siebers, S.
    Urlichs, F.
    ZENTRALBLATT FUR ARBEITSMEDIZIN ARBEITSSCHUTZ UND ERGONOMIE, 2023, 73 (01): : 24 - 31
  • [25] Internal noise levels in neonatal intensive care unit incubators
    Peixoto, Priscila Vendramini
    Balbino, Flavia Simphronio
    Eliana Moreira Pinheiro, Veridiana Chimirri
    Kakehashi, Tereza Yoshiko
    ACTA PAULISTA DE ENFERMAGEM, 2011, 24 (03) : 359 - 364
  • [26] Noise levels in a neonatal intensive care unit in the Cape metropole
    Nathan, Lisa M.
    Tuomi, Seppo K.
    Muller, Alida M. U.
    Kirsten, Gert F.
    SOUTH AFRICAN JOURNAL OF CHILD HEALTH, 2008, 2 (02) : 50 - 54
  • [27] Noise exposure of the newborn in the incubator at the neonatal intensive care unit
    Bieber, C.
    Thoma, R.
    KLINISCHE PADIATRIE, 2007, 219 (02): : 105 - 105
  • [28] NOISE-LEVELS IN NEONATAL INTENSIVE-CARE UNIT
    VIDYASAGAR, D
    JOSEPH, ME
    HAMILTON, LR
    JOURNAL OF PEDIATRICS, 1976, 88 (01): : 115 - 115
  • [29] Peak noise distribution in the neonatal intensive care unit † 1113
    Alex F Robertson
    Celeste Cooper-Peel
    Paul Vos
    Pediatric Research, 1998, 43 (Suppl 4) : 191 - 191
  • [30] Noise in an intensive care unit
    Salandin, Andrea
    Arnold, Joerg
    Kornadt, Oliver
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 130 (06): : 3754 - 3760