Effect of Soil Resistivity on Magnetic Field in the case of Lightning Strike to a Tall Structure

被引:0
|
作者
Rameli, N. [1 ]
Ab-Kadir, M. Z. A. [1 ]
Izadi, M. [1 ]
Gomes, C. [1 ]
Azis, N. [1 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Ctr Electromagnet & Lightning Protect Res CELP, Serdang 43400, Selangor, Malaysia
关键词
component; lightning; tower; magnetic field; foil resistivity; ground reflection factor; ELECTROMAGNETIC-FIELDS; TOWERS; EXPRESSIONS; MODELS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When a tower is struck by lightning, an induced voltage can generate in conducting objects within its vicinity. This phenomenon is due to the interaction between the electromagnetic field of the lightning with the object. The magnetic field is part of this field. Previous studies have shown that the magnetic field is affected by ground reflection coefficient factors that are usually taken as constants. However, the ground reflection coefficient factors have correlation with tower and ground impedance whereby the ground impedance can be determined based on soil resistivity and grounding system. This paper investigates the effect of soil resistivity on the value of magnetic field for a case of lightning strike on tall structures. Lightning current has been modelled accordingly and a set of equations is proposed to evaluate the magnetic field. Also, the effects of soil resistivity on the value of ground reflection coefficient factor consequently of the magnetic peak have been investigated. The results indicate that the magnetic field changes substantially with a variation of the soil resistivity. The magnetic field peak also has a strong correlation with the changes of soil resistivity as well as the fast front time of the channel base current. The outcome of the result of this paper will be beneficial to utility companies in determining the appropriate level of lightning protection since the magnetic field will be a result of induced voltage when have interaction with power lines.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Analysis of LEMP field inside LPS in the case of indirect lightning strike
    Aniserowicz, Karol
    PROCEEDINGS OF THE XVII INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC DISTURBANCES, EMD 2007, 2007, : 203 - 206
  • [12] Electric and magnetic field distribution nearby fuel tank during lightning strike
    Sowa, Andrzej W.
    Wiater, Jaroslaw M.
    XVI INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC DISTURBANCES : EMD 2006 - PROCEEDINGS, 2006, : 120 - 121
  • [13] A CASE OF WINTER LIGHTNING INITIATION FROM A TALL STRUCTURE IN THE BASQUE COUNTRY
    Lopez, Javier
    Montanya, Joan
    Maruri, Mercedes
    Antonio Aranda, Jose
    Gaztelumendi, Santiago
    2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [14] Lightning current and magnetic field parameters caused by lightning strikes to tall structures relating to interference of electronic systems
    Fuchs, F
    Landers, EU
    Schmid, R
    Wiesinger, J
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1998, 40 (04) : 444 - 451
  • [15] Effect of the grounding system on the lightning current profile along a tall structure
    Rameli, Norhidayu
    Ab-Kadir, Mohd Zainal Abidin
    Izadi, Mahdi
    Gomes, Chandima
    Azis, Norhafiz
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (06) : 717 - 727
  • [16] Calculation of magnetic field in a steel structure struck by lightning
    Zhang, XQ
    Chen, SM
    Ji, JQ
    APPLIED ELECTROMAGNETICS (II), 1998, 7 : 117 - 122
  • [17] Analysis of the influence of mixed path soil on lightning radiation magnetic field
    Zhao, Zhi-Bin
    Zhang, Ming-Xia
    Cui, Xiang
    Chen, Jia-Hong
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (09): : 2291 - 2296
  • [18] Lightning electric field in the soil and its effect to buried cables
    Klairuang, N.
    Khatsaeng, T.
    Hokierti, J.
    IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 782 - 787
  • [19] Currents and Electric Field Characteristics at Structure during Direct Lightning Strike and Issue of Separation Distance
    Bondar, Oleksii
    Shostak, Volodymyr
    Smatloch, Thomas
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [20] Effect of Soil Structure Interaction on the Design of Tall Concrete Buildings
    AlKhayat, AlZahraa
    Hassan, Tarek
    Ahmed, Sayed M.
    Moustafa, Ayman
    GEO-CONGRESS 2023: GEOTECHNICAL SYSTEMS FROM PORE-SCALE TO CITY-SCALE, 2023, : 312 - 322