Digital gamma-ray spectroscopy based on FPGA technology

被引:49
|
作者
Bofic, M [1 ]
Drndarevic, V [1 ]
机构
[1] Inst Nucl Sci Vinca, Dept Elect, YU-11001 Belgrade, Yugoslavia
关键词
digital pulse processing; pulse height; spectroscopy; pile-up; FPGA devices;
D O I
10.1016/S0168-9002(01)01925-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A digital pulse processing system convenient for high rate gamma-ray spectroscopy with NaI(Tl) detectors has been designed. The new programmable logic device has been used for implementation of dedicated high-speed pulse processor, as the central part of the system. The processor is capable to operate at the speed of fast ADC, preserving maximum throughput of the system. Special care has been taken to reduce the distortion of energy spectrum caused by pile-up at high-count rates. The developed system is highly flexible, and the parameters of its operation can be changed in software. The performance of the system was tested for high counting rate of 400 000 s(-1). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 50 条
  • [21] Gamma-ray spectroscopy of galactic nucleosynthesis
    Diehl, Roland
    Greiner, Jochen
    Krause, Martin G. H.
    Pleintinger, Moritz M. M.
    Siegert, Thomas
    NUCLEAR PHYSICS IN ASTROPHYSICS - X, NPA-X 2022, 2023, 279
  • [22] The spectroscopy of classical gamma-ray bursts
    Band, DL
    HIGH VELOCITY NEUTRON STARS AND GAMMA-RAY BURSTS, 1996, (366): : 206 - 210
  • [23] GAMMA-RAY SPECTROSCOPY AT THE UNIVERSITY OF LOWELL
    WANG, ATY
    MITTLER, A
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (02): : 112 - 112
  • [24] Gamma-ray line spectroscopy with INTEGRAL
    vonBallmoos, P
    Dean, T
    Winkler, C
    SEVENTEENTH TEXAS SYMPOSIUM ON RELATIVISTIC ASTROPHYSICS AND COSMOLOGY, 1995, 759 : 401 - 405
  • [25] SITU SUBTERRANEAN GAMMA-RAY SPECTROSCOPY
    NIELSON, HL
    WOGMAN, NA
    BRODZINSKI, RL
    NUCLEAR INSTRUMENTS & METHODS, 1977, 143 (02): : 385 - 389
  • [26] Online gamma-ray spectroscopy acquisition
    Yang, Xue
    Garcia, Roel
    ANNALS OF NUCLEAR ENERGY, 2018, 115 : 105 - 115
  • [27] ANALYSIS OF GAMMA-RAY SPECTROSCOPY DATA
    BARAN, JA
    REYNOLDS, RS
    FAW, RE
    KIMEL, WR
    NUCLEAR APPLICATIONS AND TECHNOLOGY, 1970, 9 (04): : 591 - &
  • [28] GAMMA-RAY SPECTROSCOPY OF AS-76
    IIZAWA, K
    KITAMURA, I
    KAWADE, K
    YAMAMOTO, H
    YOSHIKAWA, K
    AMEMIYA, S
    KATOH, T
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1971, 30 (04) : 901 - +
  • [29] COMPTON RECOIL GAMMA-RAY SPECTROSCOPY
    GOLD, R
    NUCLEAR INSTRUMENTS & METHODS, 1970, 84 (02): : 173 - &
  • [30] COINCIDENCE SUMMING IN GAMMA-RAY SPECTROSCOPY
    SEMKOW, TM
    MEHMOOD, G
    PAREKH, PP
    VIRGIL, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 290 (2-3): : 437 - 444