C-arm cone-beam computed tomography with stereotactic needle guidance for percutaneous adrenal biopsy: initial experience

被引:10
|
作者
Jiao, Dechao [1 ]
Xie, Na [2 ]
Wu, Gang [1 ]
Ren, JianZhuang [1 ]
Han, Xinwei [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Intervent Radiol, Zhengzhou, Henan, Peoples R China
[2] Anyang Dist Hosp Puyang City, Dept Neurol, Anyang, Henan Province, Peoples R China
关键词
Biopsy; cone-beam computed tomography (CBCT); virtual navigation; adrenal gland; RENAL MASSES; SYSTEM; ACCURACY; ADENOMA; PET/CT;
D O I
10.1177/0284185116661882
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Metastasis to the adrenal glands is frequent in patients with various cancers and adrenal gland biopsy is routinely performed using ultrasound or computed tomographic (CT) guidance. However, this method is technically challenging, especially in the case of small masses. Purpose: To determine whether the new real-time stereotactic needle guidance technique C-arm cone-beam CT (CBCT) allows safe and accurate biopsy of adrenal gland masses, especially those in hard-to-reach anatomical locations. Material and Methods: CBCT guidance was used to perform 60 stereotactic biopsy procedures of lesions that were inaccessible with ultrasound or CT guidance. The needle path was carefully planned and calculated on the CBCT virtual navigation guidance system, which acquired 3D CT-like cross-sectional images. The adrenal biopsy procedures were performed with fluoroscopic feedback. Technical success rate, sensitivity, specificity, accuracy, and complications were investigated. Results: The technical success rate of adrenal biopsy under CBCT virtual navigation was 100%, with a mean total procedure time of 14.6 +/- 3.6min. Of the 60 lesions, 46 were malignant, 11 were benign, and three were non-diagnostic. The three non-diagnostic lesions proved to be malignant. Thus, the sensitivity, specificity, and accuracy were 93.8%, 100%, and 95.0%, respectively. Minor bleeding occurred in two (3.3%) cases. Conclusion: CBCT guidance allows safe and accurate biopsy of adrenal gland masses and may be especially useful for hard-to-reach anatomical locations.
引用
收藏
页码:617 / 624
页数:8
相关论文
共 50 条
  • [31] Survival Impact of C-Arm Cone-Beam Computed Tomography on Hepatocellular Carcinoma Patients Undergoing Chemoembolization
    Wallace, Michael J.
    Abdelsalam, Mohamed E.
    Ensor, Joseph E.
    Kaseb, Ahmed O.
    Tam, Alda
    Avritscher, Rony
    Gupta, Sanjay
    HEPATOLOGY, 2012, 56 : 466A - 467A
  • [32] Erratum to: C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Chiara Floridi
    Alessandro Radaelli
    Nadine Abi-Jaoudeh
    Michael Grass
    MingDe Lin
    Melanie Chiaradia
    Jean-Francois Geschwind
    Hicham Kobeiter
    Ettore Squillaci
    Geert Maleux
    Andrea Giovagnoni
    Luca Brunese
    Bradford Wood
    Gianpaolo Carrafiello
    Antonio Rotondo
    La radiologia medica, 2015, 120 : 406 - 406
  • [33] Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy
    Braak, Sicco J.
    Herder, Gerarda J. M.
    van Heesewijk, Johannes P. M.
    van Strijen, Marco J. L.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (06) : 1414 - 1421
  • [34] Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy
    Sicco J. Braak
    Gerarda J. M. Herder
    Johannes P. M. van Heesewijk
    Marco J. L. van Strijen
    CardioVascular and Interventional Radiology, 2012, 35 : 1414 - 1421
  • [35] Percutaneous transthoracic localization of pulmonary nodules under C-arm cone-beam CT virtual navigation guidance
    Kim, Tae Ho
    Park, Chang Min
    Lee, Sang Min
    McAdams, H. Page
    Kim, Young Tae
    Goo, Jin Mo
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2016, 22 (03) : 224 - 230
  • [36] Feasibility Study of Needle Placement in Percutaneous Vertebroplasty: Cone-Beam Computed Tomography Guidance Versus Conventional Fluoroscopy
    Braak, Sicco J.
    Zuurmond, Kirsten
    Aerts, Hans C. J.
    van Leersum, Marc
    Overtoom, Timotheus T. Th.
    van Heesewijk, Johannes P. M.
    van Strijen, Marco J. L.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (04) : 1120 - 1126
  • [37] Feasibility Study of Needle Placement in Percutaneous Vertebroplasty: Cone-Beam Computed Tomography Guidance Versus Conventional Fluoroscopy
    Sicco J. Braak
    Kirsten Zuurmond
    Hans C. J. Aerts
    Marc van Leersum
    Timotheus T. Th. Overtoom
    Johannes P. M. van Heesewijk
    Marco J. L. van Strijen
    CardioVascular and Interventional Radiology, 2013, 36 : 1120 - 1126
  • [38] C-Arm Cone-Beam Volume CT in Transjugular Intrahepatic Portosystemic Shunt: Initial Clinical Experience
    Luo, Xuefeng
    Ye, Linchao
    Zhou, Xuan
    Tsauo, Jiaywei
    Zhou, Biao
    Zhang, Hailong
    Zhang, Xiaowu
    Li, Xiao
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (06) : 1627 - 1631
  • [39] C-Arm Cone-Beam Volume CT in Transjugular Intrahepatic Portosystemic Shunt: Initial Clinical Experience
    Xuefeng Luo
    Linchao Ye
    Xuan Zhou
    Jiaywei Tsauo
    Biao Zhou
    Hailong Zhang
    Xiaowu Zhang
    Xiao Li
    CardioVascular and Interventional Radiology, 2015, 38 : 1627 - 1631
  • [40] Stereotactic registration using cone-beam computed tomography
    Carlson, Jonathan Dennis
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 182 : 107 - 111