C-arm cone-beam computed tomography with stereotactic needle guidance for percutaneous adrenal biopsy: initial experience

被引:10
|
作者
Jiao, Dechao [1 ]
Xie, Na [2 ]
Wu, Gang [1 ]
Ren, JianZhuang [1 ]
Han, Xinwei [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Intervent Radiol, Zhengzhou, Henan, Peoples R China
[2] Anyang Dist Hosp Puyang City, Dept Neurol, Anyang, Henan Province, Peoples R China
关键词
Biopsy; cone-beam computed tomography (CBCT); virtual navigation; adrenal gland; RENAL MASSES; SYSTEM; ACCURACY; ADENOMA; PET/CT;
D O I
10.1177/0284185116661882
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Metastasis to the adrenal glands is frequent in patients with various cancers and adrenal gland biopsy is routinely performed using ultrasound or computed tomographic (CT) guidance. However, this method is technically challenging, especially in the case of small masses. Purpose: To determine whether the new real-time stereotactic needle guidance technique C-arm cone-beam CT (CBCT) allows safe and accurate biopsy of adrenal gland masses, especially those in hard-to-reach anatomical locations. Material and Methods: CBCT guidance was used to perform 60 stereotactic biopsy procedures of lesions that were inaccessible with ultrasound or CT guidance. The needle path was carefully planned and calculated on the CBCT virtual navigation guidance system, which acquired 3D CT-like cross-sectional images. The adrenal biopsy procedures were performed with fluoroscopic feedback. Technical success rate, sensitivity, specificity, accuracy, and complications were investigated. Results: The technical success rate of adrenal biopsy under CBCT virtual navigation was 100%, with a mean total procedure time of 14.6 +/- 3.6min. Of the 60 lesions, 46 were malignant, 11 were benign, and three were non-diagnostic. The three non-diagnostic lesions proved to be malignant. Thus, the sensitivity, specificity, and accuracy were 93.8%, 100%, and 95.0%, respectively. Minor bleeding occurred in two (3.3%) cases. Conclusion: CBCT guidance allows safe and accurate biopsy of adrenal gland masses and may be especially useful for hard-to-reach anatomical locations.
引用
收藏
页码:617 / 624
页数:8
相关论文
共 50 条
  • [1] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Chiara Floridi
    Alessandra Muollo
    Federico Fontana
    Nicola Rotolo
    Anna Maria Ierardi
    Ejona Duka
    Carlo Pellegrino
    Gianpaolo Carrafiello
    La radiologia medica, 2014, 119 : 820 - 827
  • [2] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Floridi, Chiara
    Muollo, Alessandra
    Fontana, Federico
    Rotolo, Nicola
    Ierardi, Anna Maria
    Duka, Ejona
    Pellegrino, Carlo
    Carrafiello, Gianpaolo
    RADIOLOGIA MEDICA, 2014, 119 (11): : 820 - 827
  • [3] Percutaneous transthoracic needle biopsy for pulmonary nodules: a retrospective study of a comparison between C-arm cone-beam computed tomography and conventional computed tomography guidance
    Akkakrisee, Surasit
    Hongsakul, Keerati
    POLISH JOURNAL OF RADIOLOGY, 2020, 85 : E309 - E315
  • [4] Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems
    Kwang Nam Jin
    Chang Min Park
    Jin Mo Goo
    Hyun Ju Lee
    Youkyung Lee
    Jung Im Kim
    So Young Choi
    Hyo-Cheol Kim
    European Radiology, 2010, 20 : 2108 - 2115
  • [5] Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems
    Jin, Kwang Nam
    Park, Chang Min
    Goo, Jin Mo
    Lee, Hyun Ju
    Lee, Youkyung
    Kim, Jung Im
    Choi, So Young
    Kim, Hyo-Cheol
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2108 - 2115
  • [6] Learning Curve of C-Arm Cone-beam Computed Tomography Virtual. Navigation-Guided Percutaneous Transthoracic Needle Biopsy
    Ahn, Su Yeon
    Park, Chang Min
    Yoon, Soon Ho
    Kim, Hyungjin
    Goo, Jin Mo
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (05) : 844 - 853
  • [7] C-Arm Cone-Beam CT Combined with a New Electromagnetic Navigation System for Guidance of Percutaneous Needle Biopsies: Initial Clinical Experience
    Kickuth, R.
    Reichling, C.
    Bley, T.
    Hahn, D.
    Ritter, C.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (07): : 569 - 576
  • [8] Respiratory correlated cone-beam computed tomography on an isocentric C-arm
    Kriminski, S
    Mitschke, M
    Sorensen, S
    Wink, NM
    Chow, PE
    Tenn, S
    Solberg, TD
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (22): : 5263 - 5280
  • [9] Percutaneous Transthoracic Lung Biopsy: Comparison Between C-Arm Cone-Beam CT and Conventional CT Guidance
    Cheng, Yun-Chung
    Tsai, Sheng-Heng
    Cheng, Yuchi
    Chen, Jeon-Hor
    Chai, Jyh-Wen
    Chen, Clayton Chi-Chang
    TRANSLATIONAL ONCOLOGY, 2015, 8 (04): : 258 - 264
  • [10] Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose
    Fior, Davide
    Vacirca, Francesco
    Leni, Davide
    Pagni, Fabio
    Ippolito, Davide
    Riva, Luca
    Sironi, Sandro
    Corso, Rocco
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (05) : 712 - 719