Improvement of Immunomagnetic separation for Escherichia coli O157:H7 detection by the PickPen magnetic particle separation device

被引:33
|
作者
Nou, Xiangwu [1 ]
Arthur, Terrance M. [1 ]
Bosilevac, Joseph M. [1 ]
Brichta-Harhay, Dayna M. [1 ]
Guerini, Michael N. [1 ]
Kalchayanand, Norasak [1 ]
Koohmaraie, Mohammad [1 ]
机构
[1] USDA ARS, Roman L Hruska US Meat Anim Res Ctr, Clay Ctr, NE 68933 USA
关键词
D O I
10.4315/0362-028X-69.12.2870
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Conventional immunomagnetic separation (IMS) procedures, which use an external magnetic source to capture magnetic particles against the side of a test tube, are labor-intensive and can have poor sensitivity for the target organism because of high background microflora that is not effectively washed away during the IMS process. This report compares the conventional IMS procedure to a new IMS procedure with an intrasolution magnetic particle transfer device, the PickPen. The IMS target for the majority of these studies is Escherichia coli O157:H7 in various types of samples, including cattle feces, hides, carcasses, and ground beef. Comparison of the two IMS methods showed a significant difference (P < 0.05) in the efficiency of detecting E. coli O157:H7 from cattle carcass surface, cattle hide, and cattle fecal samples. No significant improvement (P > 0.05) in E. coli O157:H7 detection was observed when the PickPen IMS procedure was used to isolate this pathogen from ground beef samples. Use of the PickPen IMS greatly increases the throughput of the IMS procedure and may be more compatible with various emerging technologies for pathogen detection. In addition, the efficacy of sequential IMS for multiple pathogens is reported herein.
引用
收藏
页码:2870 / 2874
页数:5
相关论文
共 50 条
  • [41] The isolation and detection of Escherichia coli O157 by use of immunomagnetic separation and immunoassay procedures
    Bennett, AR
    MacPhee, S
    Betts, RP
    LETTERS IN APPLIED MICROBIOLOGY, 1996, 22 (03) : 237 - 243
  • [42] The isolation and detection of Escherichia coli O157 by use of immunomagnetic separation and immunoassay procedures
    Campden Chorleywood Food Res. Assoc., Chipping Campden, Glos, United Kingdom
    不详
    LETT. APPL. MICROBIOL., 3 (237-243):
  • [43] Automated immunomagnetic separation and microarray detection of E-coli O157:H7 from poultry carcass rinse
    Chandler, DP
    Brown, J
    Call, DR
    Wunschel, S
    Grate, JW
    Holman, DA
    Olson, L
    Stottlemyre, MS
    Bruckner-Lea, CJ
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2001, 70 (1-2) : 143 - 154
  • [44] Comparison of the sensitivity of manual and automated immunomagnetic separation methods for detection of Shiga toxin-producing Escherichia coli O157:H7 in milk
    Reinders, RD
    Barna, A
    Lipman, LJA
    Bijker, PGH
    JOURNAL OF APPLIED MICROBIOLOGY, 2002, 92 (06) : 1015 - 1020
  • [46] Direct PCR detection of Escherichia coli O157:H7
    Fode-Vaughan, KA
    Maki, JS
    Benson, JA
    Collins, MLP
    LETTERS IN APPLIED MICROBIOLOGY, 2003, 37 (03) : 239 - 243
  • [47] Rapid detection of Escherichia coli O157:H7 in water
    Bukhari, Zia
    Weihe, Janice R.
    Lechevallier, Mark W.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2007, 99 (09): : 157 - 167
  • [48] Polymerase chain reaction assay for detection of Escherichia coli O157: H7 and Escherichia coli O157:H-
    Miyamoto, T
    Ichioka, N
    Sasaki, C
    Kobayashi, H
    Honjoh, K
    Iio, M
    Hatano, S
    JOURNAL OF FOOD PROTECTION, 2002, 65 (01) : 5 - 11
  • [49] Strategies for the detection of Escherichia coli O157:H7 in foods
    Deisingh, AK
    Thompson, M
    JOURNAL OF APPLIED MICROBIOLOGY, 2004, 96 (03) : 419 - 429
  • [50] Strategies for the detection of Escherichia coli O157:H7 in foods
    Deisingh, A.K. (anildeisingh@aol.com), 1600, Blackwell Publishing Ltd (96):