Heat transfer and flow temperature measurements in a rotating triangular channel with various rib arrangements

被引:14
|
作者
Lee, Dong Hyun [1 ]
Rhee, Dong-Ho [2 ]
Kim, Kyung Min [1 ]
Cho, Hyung Hee [1 ]
Moon, Hee-Koo [3 ]
机构
[1] Yonsei Univ, Sch Mech Engn, Seoul 120749, South Korea
[2] Korea Aerosp Res Inst, Taejon 305333, South Korea
[3] Solar Turbines Inc, San Diego, CA 92186 USA
关键词
HEAT/MASS TRANSFER; FORCED-CONVECTION; PRESSURE-DROP; MASS-TRANSFER; 2-PASS DUCTS; SQUARE DUCT; FRICTION;
D O I
10.1007/s00231-009-0529-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present study, the regionally-averaged heat transfer coefficients and flow temperature distributions were measured in an equilateral triangular channel with three different rib arrangements (alpha = 45, 90 and 135 degrees). To measure regionally-averaged heat transfer coefficients in the channel, two rows of copper blocks and a single heater were installed on two ribbed walls. The fluid temperature distributions were obtained using a thermocouple-array. The rotation number ranged from 0.0 to 0.1 with a fixed Reynolds number of 10,000. For the 90 degrees ribs, the heat transfer coefficients on the pressure side surface were increased significantly with rotation, while the suction side surface had lower heat transfer coefficients than the stationary channel. For the angled ribs, rib-induced secondary flow dominated the heat transfer characteristics and high heat transfer rates were observed on the regions near the inner wall for the 45 degrees angled ribs and near the leading edge for the 135 degrees angled ribs.
引用
收藏
页码:1543 / 1553
页数:11
相关论文
共 50 条
  • [21] Fluid flow and heat transfer in a turbulent channel flow with insertion of a triangular cylinder
    Sano, Masatoshi
    Takahara, Syuji
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2007, 73 (07): : 1525 - 1533
  • [22] Flow and impingement cooling heat transfer along triangular rib-roughened walls
    Gau, C
    Lee, IC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (24) : 4405 - 4418
  • [23] Heat transfer enhancement of turbulent forced nanofluid flow in a duct using triangular rib
    Ahmed, Hamdi E.
    Salman, B. H.
    Kerbeet, A. Sh
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 134 : 30 - 40
  • [24] Turbulence, instabilities and heat transfer in rotating channel flow simulations
    Brethouwer, G.
    Wei, L.
    Schlatter, P.
    Johansson, A. V.
    THMT-12. PROCEEDINGS OF THE SEVENTH INTERNATIONAL SYMPOSIUM ON TURBULENCE, HEAT AND MASS TRANSFER, 2012, : 703 - 706
  • [26] Experimental study of heat and momentum transfer in rotating channel flow
    Matsubara, M
    Alfredsson, PH
    PHYSICS OF FLUIDS, 1996, 8 (11) : 2964 - 2973
  • [27] Local heat transfer measurements of an orthogonally rotating square duct with angled rib turbulators
    Murata, A
    Mochizuki, S
    Takahashi, T
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (16) : 3047 - 3056
  • [28] Liquid crystal heat transfer measurements in a rectangular channel with solid and slit rib
    P. K. Panigrahi
    A. Tariq
    Journal of Visualization, 2003, 6 : 407 - 416
  • [29] HEAT TRANSFER ON ROTATING CHANNEL WITH VARIOUS HEIGHTS OF PIN-FIN
    Park, Jun Su
    Kim, Kyung Min
    Lee, Dong Hyun
    Cho, Hyung Hee
    Chyu, Minking K.
    PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 4, PTS A AND B, 2008, : 727 - 734
  • [30] Liquid crystal heat transfer measurements in a rectangular channel with solid and slit rib
    Panigrahi, PK
    Tariq, A
    JOURNAL OF VISUALIZATION, 2003, 6 (04) : 407 - 416