The baffled flask test for dispersant effectiveness: A round robin evaluation of reproducibility and repeatability

被引:78
|
作者
Venosa, AD
King, DW
Sorial, GA
机构
[1] US EPA, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA
[2] Statking Consulting Inc, Fairfield, OH 45014 USA
[3] Univ Cincinnati, Dept Civil & Environm Engn, Cincinnati, OH 45221 USA
关键词
baffled flask test; swirling flask test; dispersants; round robin test; interlaboratory test; dispersion effectiveness; crude oil;
D O I
10.1016/S1353-2561(02)00072-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
After two previous investigations demonstrated that the baffled flask test was an effective and reproducible method for screening the effectiveness of dispersant products in the laboratory, the US Environmental Protection Agency decided that before the new protocol could be considered for replacement of the swirling flask test, it would have to be subjected to an interlaboratory round robin investigation. This paper describes how the round robin evaluation was carried out and presents repeatability and reproducibility calculations that demonstrate the superiority of the new method over previous methods. Probabilities for passing various threshold levels of effectiveness values were computed, and the results will be used by the Agency to develop final pass-fail decision rules for dispersant manufacturers wishing to have their products listed on the national contingency plan product schedule. Published by Elsevier Science Ltd.
引用
收藏
页码:299 / 308
页数:10
相关论文
共 50 条
  • [21] Evaluation of the Data Quality from a Round-Robin Test of Hyperspectral Imaging Systems
    Pillay, Ruven
    Picollo, Marcello
    Hardeberg, Jon Yngve
    George, Sony
    SENSORS, 2020, 20 (14) : 1 - 26
  • [22] Round-robin test for nondestructive evaluation of steel components in nuclear power plants
    Uesaka, M
    Gilanyi, A
    Sukegawa, T
    Miya, K
    Yamada, K
    Toyooka, S
    Kasai, N
    Chiba, A
    Takahashi, S
    Morishita, K
    Ara, K
    Ebine, N
    Isobe, Y
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (II), 1998, 14 : 39 - 48
  • [23] Evaluation for Standardization of 1H Quantitative NMR Spectroscopy by Round Robin Test
    Miura, Toru
    Sugimoto, Naoki
    Watanabe, Ryuichi
    Suematsu, Takako
    Takayanagi, Yoichiro
    Ito, Yoshinobu
    Saito, Naoki
    Sawa, Ryuichi
    Kato, Tsuyoshi
    Fujimine, Yoshinori
    Koike, Ryo
    Ohfuku, Yuko
    Yamada, Yuko
    Utsumi, Hiroaki
    Suzuki, Toshiyuki
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2017, 137 (12): : 1543 - 1553
  • [24] Electrochemical Noise Measurements with Dummy Cells: Evaluation of a Round-Robin Test Series
    Huet, Francois
    Ritter, Stefan
    CORROSION, 2018, 74 (12) : 1457 - 1465
  • [25] ROUND-ROBIN EVALUATION OF THICKNESS TEST METHODS FOR GRAY CAST-IRON
    MOSKAL, MD
    TAPPI JOURNAL, 1991, 74 (03): : 159 - 163
  • [26] Comparison of the Effectiveness of Solid and Solubilized Dioctyl Sodium Sulfosuccinate (DOSS) on Oil Dispersion Using the Baffled Flask Test, for Crude Oil Spill Applications
    Nyankson, Emmanuel
    Ober, Courtney A.
    DeCuir, Matthew J.
    Gupta, Ram B.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (29) : 11862 - 11872
  • [27] A ROUND ROBIN PROGRAM OF MASTER CURVE EVALUATION USING MINIATURE C(T) SPECIMENS: FIRST ROUND ROBIN TEST ON UNIFORM SPECIMENS OF REACTOR PRESSURE VESSEL MATERIAL
    Yamamoto, Masato
    Kimura, Akihiko
    Onizawa, Kunio
    Yoshimoto, Kentaro
    Ogawa, Takuya
    Chiba, Atsushi
    Hirano, Takashi
    Sugihara, Takuji
    Sugiyama, Masanari
    Miura, Naoki
    Soneda, Naoki
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, PVP 2012, VOL 6, PTS A AND B, 2012, : 73 - 79
  • [28] Examination of Dynamic Drop Test method for evaluation of hydrophobicity stability of polymeric insulating materials by CIGRE Round Robin Test
    Electric Power Engineering Research Laboratory, Central Research Institute of Electric Power Industry, 2-6-1, Nagasaka, Yokosuka, Kanagawa 240-0196, Japan
    不详
    不详
    不详
    不详
    IEEJ Trans. Fundam. Mater., 1600, 9 (797-803):
  • [29] Reproducibility of Immunohistochemical Scoring for Epidermal Growth Factor Receptor Expression in Non-Small Cell Lung Cancer Round Robin Test
    Rueschoff, Josef
    Kerr, Keith M.
    Grote, Hans J.
    Middel, Peter
    von Heydebreck, Anja
    Alves, Venancio A.
    Baldus, Stephan E.
    Buettner, Reinhard
    Carvalho, Lina
    Fink, Ludger
    Jochum, Wolfram
    Lo, Anthony W. I.
    Lopez-Rios, Fernando
    Marx, Alexander
    Molina, Thierry J.
    Olszewski, Wlodzimierz T.
    Rieker, Ralf J.
    Volante, Marco
    Thunnissen, Erik
    Wrba, Fritz
    Celik, Ilhan
    Stoerkel, Stephan
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2013, 137 (09) : 1255 - 1261
  • [30] RILEM TC 247-DTA round robin test: mix design and reproducibility of compressive strength of alkali-activated concretes
    John L. Provis
    Kamel Arbi
    Susan A. Bernal
    Dali Bondar
    Anja Buchwald
    Arnaud Castel
    Sundararaman Chithiraputhiran
    Martin Cyr
    Alireza Dehghan
    Katja Dombrowski-Daube
    Ashish Dubey
    Vilma Ducman
    Gregor J. G. Gluth
    Sreejith Nanukuttan
    Karl Peterson
    Francisca Puertas
    Arie van Riessen
    Manuel Torres-Carrasco
    Guang Ye
    Yibing Zuo
    Materials and Structures, 2019, 52