Purpose:To investigate the retinal light hazard during macular surgery using a digital three-dimensional visualization system (3D) and a conventional microscope (CM).Design:Experimental study and retrospective evaluation of a case-control study.Subjects:A total of 20 and 10 patients who underwent pars plana vitrectomy for epiretinal membrane using 3D and CM, respectively.Methods:Spectral irradiances of endoilluminators were measured for representative settings used during core vitrectomy and macular manipulations with 3D and CM. From the medical record of the patients, time needed for core vitrectomy and macular manipulations was extracted. The total retinal light hazard index and the macular hazard index were calculated based on the spectral irradiances weighted by the standard functions. Total retinal light hazard index, macular hazard index, and the number of cases that exceeded the maximum permissible radiant power exposure were compared between the two groups.Results:The spectral irradiance were 1.6 and 3.9 mW/cm(2) for core vitrectomy and 3.4 and 8.1 mW/cm(2) for macular manipulations using typical settings for 3D and CM groups, respectively. The total retinal light hazard index ranged from 4.31 kJ/m(2) to 17.37 kJ/m(2) for 3D and 11.09 kJ/m(2) to 27.70 kJ/m(2) for CM groups, respectively, whereas the macular hazard index ranged from 2.93 kJ/m(2) to 14.58 kJ/m(2) for 3D and from 6.84 kJ/m(2) to 23.55 kJ/m(2) for CM, respectively (P < 0.001). One (5%) and 6 (60%) pars plana vitrectomy cases exceeded the threshold limits with 3D and CM groups, respectively (P < 0.05, chi-square test).Conclusion:The 3D digitally assisted visualization system offers significantly safer macular surgery compared with the CM, considering the potential retinal hazard.
引用
收藏
页码:2301 / 2306
页数:6
相关论文
共 50 条
  • [21] Design and Implementation of 3D Visualization System
    Li, Panpan
    2023 IEEE International Conference on Sensors, Electronics and Computer Engineering, ICSECE 2023, 2023, : 693 - 697
  • [22] 3D Visualization of a Public Transportation System
    Pouke, Matti
    Koskela, Timo
    Gunes, San
    Matero, Matti
    Ojala, Karri
    Pajukangas, Jukka
    Pietikainen, Niko
    Ojala, Timo
    15TH INTERNATIONAL CONFERENCE ON MOBILE AND UBIQUITOUS MULTIMEDIA (MUM 2016), 2016, : 377 - 379
  • [23] A 3D Visualization System for Structured Overlays
    Nagao, Hiroya
    Suzuki, Shuji
    Shudo, Kazuyuki
    2011 IEEE INTERNATIONAL CONFERENCE ON PEER-TO-PEER COMPUTING (P2P), 2011, : 168 - 169
  • [24] 3D video visualization on the HoloVizio™ system
    Megyesi, Zoltan
    Barsi, Attila
    Balogh, Tibor
    2008 3DTV-CONFERENCE: THE TRUE VISION - CAPTURE, TRANSMISSION AND DISPLAY OF 3D VIDEO, 2008, : 249 - 252
  • [25] WilmaScope - A 3D graph visualization system
    Dwyer, T
    Eckersley, P
    GRAPH DRAWING SOFTWARE, 2004, : 55 - 75
  • [26] 3D OCT in evaluation of retinal lesions
    Rao, Bin
    Wang, Qiang
    Yu, Lingfeng
    Kim, Jae Gwan
    Zacharias, Leandro C.
    Kurtz, Ronald M.
    Kuppermann, Baruch D.
    Chen, Zhongping
    LASERS IN SURGERY AND MEDICINE, 2008, : 11 - 11
  • [27] 3D restoration of multiple images acquired by a modified conventional microscope
    Vermolen, BJ
    Garini, Y
    Young, IT
    CYTOMETRY PART A, 2004, 59A (01): : 111 - 111
  • [28] 3D restoration with multiple images acquired by a modified conventional microscope
    Vermolen, BJ
    Garini, Y
    Young, IT
    MICROSCOPY RESEARCH AND TECHNIQUE, 2004, 64 (02) : 113 - 125
  • [29] Comparison of Surgical Performance of Internal Limiting Membrane Peeling Using a 3-D Visualization System With Conventional Microscope
    Babu, Naresh
    Kohli, Piyush
    Ramachandran, Obuli
    Ramasamy, Kim
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2018, 49 (12): : 941 - 945
  • [30] Comparing clinical outcomes of macular hole surgeries performed by trainee surgeons using a 3D heads-up display viewing system versus a standard operating microscope
    Subhakar Reddy
    Kushanth Mallikarjun
    Ashik Mohamed
    Prithvi Mruthyunjaya
    Vivek Pravin Dave
    Rajeev Reddy Pappuru
    Jay Chhablani
    Raja Narayanan
    International Ophthalmology, 2021, 41 : 2649 - 2655