Test-Retest Reliability and Concurrent Validity of an fMRI-Compatible Pneumatic Vibrator to Stimulate Muscle Proprioceptors

被引:13
|
作者
Goossens, Nina [1 ]
Janssens, Lotte [1 ,2 ]
Pijnenburg, Madelon [1 ]
Caeyenberghs, Karen [3 ]
Van Rompuy, Charlotte [1 ]
Meugens, Paul [1 ]
Sunaert, Stefan [4 ]
Brumagne, Simon [1 ]
机构
[1] Univ Leuven, KU Leuven, Fac Kinesiol & Rehabil Sci, Dept Rehabil Sci, Tervuursevest 101,Box 1501, B-3001 Leuven, Belgium
[2] Hasselt Univ, Biomed Res Inst, Agoralaan A, B-3590 Diepenbeek, Belgium
[3] Australian Catholic Univ, Fac Hlth Sci, Sch Psychol, Melbourne Campus St Patrick,Locked Bag 4115, Fitzroy Mdc, Vic 3065, Australia
[4] Univ Leuven, KU Leuven, Dept Imaging & Pathol, UZ Herestr 49,Box 7003, B-3000 Leuven, Belgium
关键词
Reproducibility of results; proprioception; muscle spindle; postural balance; vibration; magnetic resonance imaging; LOW-BACK-PAIN; POSITION SENSE; POSTURAL SWAY; BALANCE; YOUNG; MOTOR; CORTEX; INSTABILITY; PARKINSONS; MOVEMENT;
D O I
10.1163/22134808-00002526
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Processing proprioceptive information in the brain is essential for optimal postural control and can be studied with proprioceptive stimulation, provided by muscle vibration, during functional magnetic resonance imaging (fMRI). Classic electromagnetic muscle vibrators, however, cannot be used in the high-strength magnetic field of the fMRI scanner. Pneumatic vibrators offer an fMRI-compatible alternative. However, whether these devices produce reliable and valid proprioceptive stimuli has not been investigated, although this is essential for these devices to be used in longitudinal research. Test-retest reliability and concurrent validity of the postural response to muscle vibration, provided by custom-made fMRI-compatible pneumatic vibrators, were assessed in a repeated-measures design. Mean center of pressure (CoP) displacements during, respectively, ankle muscle and back muscle vibration (45-60 Hz, 0.5 mm) provided by an electromagnetic and a pneumatic vibrator were measured in ten young healthy subjects. The test was repeated on the same day and again within one week. Intraclass correlation coefficients (ICC) were calculated to assess (a) intra-and interday reliability of the postural responses to, respectively, pneumatic and electromagnetic vibration, and (b) concurrent validity of the response to pneumatic compared to electromagnetic vibration. Test-retest reliability of mean CoP displacements during pneumatic vibration was good to excellent (ICCs = 0.64-0.90) and resembled that of responses to electromagnetic vibration (ICCs = 0.64-0.94). Concurrent validity of the postural effect of pneumatic vibration was good to excellent (ICCs = 0.63-0.95). In conclusion, the proposed fMRI-compatible pneumatic vibrator can be used with confidence to stimulate muscle spindles during fMRI to study central processing of proprioception.
引用
收藏
页码:465 / 492
页数:28
相关论文
共 50 条
  • [21] Test-retest reliability of an isokinetic muscle endurance test
    Manou, V
    Arseniou, P
    Gerodimos, V
    Kellis, S
    ISOKINETICS AND EXERCISE SCIENCE, 2002, 10 (04) : 177 - 181
  • [22] Shuttle walking test in obese women: test-retest reliability and concurrent validity with peak oxygen uptake
    Juergensen, Soraia P.
    Trimer, Renata
    Dourado, Victor Z.
    Di Thommazo-Luporini, Luciana
    Bonjorno-Junior, Jose C.
    Oliveira, Claudio R.
    Arena, Ross
    Mendes, Renata G.
    Borghi-Silva, Audrey
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2015, 35 (02) : 120 - 126
  • [23] Test-retest reliability and convergent validity of attention measures
    Fernandez-Marcos, Tatiana
    de la Fuente, Cristina
    Santacreu, Jose
    APPLIED NEUROPSYCHOLOGY-ADULT, 2018, 25 (05) : 464 - 472
  • [24] Test-retest reliability, concurrent validity and correlates of the two-minute walk test in outpatients with psychosis
    Vancampfort, Davy
    Kimbowa, Samuel
    Basangwa, David
    Smith, Lee
    Stubbs, Brendon
    Van Damme, Tine
    De Hert, Marc
    Mugisha, James
    PSYCHIATRY RESEARCH, 2019, 282
  • [25] Concurrent Validity and Test-Retest Reliability of the 3-Meter Backward Walk Test in Stroke Survivors
    Kapan, Ali
    Ristic, Milos
    Yang, Lin
    Kranz, Gottfried
    Waldhoer, Thomas
    HEALTHCARE, 2023, 11 (23)
  • [26] Validity and test-retest reliability of photogrammetry in adolescents with hyperkyphosis
    Azadinia, Fatemeh
    Hosseinabadi, Mostafa
    Ebrahimi, Ismail
    Mohseni-Bandpei, Mohammad-Ali
    Ghandhari, Hasan
    Yassin, Marzieh
    Behtash, Hamid
    Ganjavian, Mohammad-Saleh
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (13) : 3018 - 3026
  • [27] Reaching performance scale for stroke - Test-retest reliability, measurement error, concurrent and discriminant validity
    Subramanian, Sandeep K.
    Banina, Melanie C.
    Turolla, Andrea
    Levin, Mindy F.
    PM&R, 2022, 14 (03) : 337 - 347
  • [28] THE FRENCH VERSION OF THE HONOS-LD: ADDITIONAL RESULTS ON TEST-RETEST RELIABILITY AND CONCURRENT VALIDITY
    Straccia, C.
    Gerber, F.
    Darbellay, B.
    Wagner, I. Collet
    Curtis, L.
    Kosel, M.
    JOURNAL OF INTELLECTUAL DISABILITY RESEARCH, 2019, 63 (07) : 692 - 692
  • [29] Test-retest reliability of evoked heat stimulation BOLD fMRI
    Upadhyay, Jaymin
    Lemme, Jordan
    Anderson, Julie
    Bleakman, David
    Large, Thomas
    Evelhoch, Jeffrey L.
    Hargreaves, Richard
    Borsook, David
    Becerra, Lino
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 253 : 38 - 46
  • [30] Concurrent validity and test-retest reliability of Squegg™ - smart dynamometer and handgrip trainer in healthy individuals
    Amin, Zarmina
    Gutierrez, Galilea
    True, Larissa
    HAND THERAPY, 2024, 29 (02) : 68 - 74