A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring

被引:251
|
作者
Cengiz, Eda [1 ]
Tamborlane, William V.
机构
[1] Yale Univ, Sch Med, Sect Pediat Endocrinol, New Haven, CT 06520 USA
关键词
STRATUM-CORNEUM; INSULIN; SYSTEM; TISSUE; SENSOR; ULTRASTRUCTURE; MICRODIALYSIS; HYPOGLYCEMIA; EXCURSIONS; ACCURACY;
D O I
10.1089/dia.2009.0002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, while raising questions about the relationships between interstitial and blood glucose levels. This article will review the differences between interstitial and blood glucose and some of the challenges in measuring interstitial glucose levels accurately.
引用
收藏
页码:S11 / S16
页数:6
相关论文
共 50 条
  • [11] Detection of Hypoglycemia with Continuous Interstitial and Traditional Blood Glucose Monitoring Using the FreeStyle Navigator Continuous Glucose Monitoring System
    McGarraugh, Geoffrey
    Bergenstal, Richard
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (03) : 145 - 150
  • [12] Corneal confocal microscopy meets continuous glucose monitoring: a tale of two technologies
    Malik Rayaz A.
    中华医学杂志英文版, 2022, 135 (16) : 1891 - 1893
  • [13] Corneal confocal microscopy meets continuous glucose monitoring: a tale of two technologies
    Malik, Rayaz A.
    CHINESE MEDICAL JOURNAL, 2022, 135 (16) : 1891 - 1893
  • [14] Continuous glucose monitoring versus self-monitoring of blood glucose in the treatment of gestational diabetes mellitus
    Kestila, Kirsimarja K.
    Ekblad, Ulla U.
    Ronnemaa, Tapani
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2007, 77 (02) : 174 - 179
  • [15] Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose to Assess Glycemia in Gestational Diabetes
    Zaharieva, Dessi P.
    Teng, Jessie H.
    Ong, May Lea
    Lee, Melissa H.
    Paldus, Barbora
    Jackson, Linda
    Houlihan, Christine
    Shub, Alexis
    Tipnis, Sheetal
    Cohen, Ohad
    O'Neal, David N.
    Krishnamurthy, Balasubramanian
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (11) : 822 - 827
  • [16] Venipuncture versus heel prick for blood glucose monitoring in neonates
    Saththasivam, P.
    Umadevan, D.
    Ramli, N.
    Voralu, K.
    Naing, N. N.
    Ilias, M. I.
    Shuib, N.
    Tan, B. G.
    van Rostenberghe, H.
    SINGAPORE MEDICAL JOURNAL, 2009, 50 (10) : 1004 - 1007
  • [17] DIABETIC INTERSTITIAL GLUCOSE IN THE SKIN TISSUE BY ATR-FTIR SPECTROSCOPY VERSUS CAPILLARY BLOOD GLUCOSE
    Eikje, Natalja Skrebova
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2010, 3 (02) : 81 - 90
  • [18] Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
    Del Baldo, Francesca
    Fracassi, Federico
    Pires, Jully
    Tardo, Antonio Maria
    Malerba, Eleonora
    Manassero, Elisa
    Gilor, Chen
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (03) : 1279 - 1287
  • [19] A pragmatic real-life study of flash glucose monitoring versus self-monitoring of blood glucose
    Greve, Sara, V
    Stilgren, Lis
    DANISH MEDICAL JOURNAL, 2020, 67 (06):
  • [20] Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Westhoff, Antje
    Kamecke, Ulrike
    Haug, Cornelia
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (08) : 541 - 549