Volume quantification of intracardiac mass lesions by transesophageal three-dimensional echocardiography

被引:25
|
作者
Ahmed, S
Nanda, NC
Miller, AP
Nekkanti, R
Yousif, AM
Pacifico, AD
Kirklin, JK
McGiffin, DC
机构
[1] Univ Alabama Birmingham, Heart Stn SWS102, Div Cardiovasc Dis, Birmingham, AL 35249 USA
[2] Univ Alabama Birmingham, Div Cardiothorac Surg, Birmingham, AL USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2002年 / 28卷 / 11-12期
关键词
three-dimensional echocardiography; transesophageal echocardiography; volume measurement; intracardiac tumors; infective vegetations;
D O I
10.1016/S0301-5629(02)00647-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
As compared with two-dimensional (2-D) transesophageal echocardiography (TEE), 3-D echocardiography now permits more realistic visualization of cardiac anatomy and of intracardiac lesions. The aim of this study was to apply newer 3-D echocardiographic techniques to quantify volumes of intracardiac masses undergoing surgical resection seen during an intraoperative TEE. The calculated volumes were compared with actual in vitro measurements of surgically resected masses. A total of 14 patients (9 men; 5 women; age range between 21 and 77 years) with intracardiac mass lesions (4 tumors: 3 left atrial myxomas and I mitral valve fibroelastoma, and 10 vegetations: 5 aortic valve, 3 mitral valve, 1 tricuspid and I pulmonary valve) were studied. Using commercially available 3-D reconstruction software (TomTec v. 4.1), the volumes of intracardiac masses were estimated using both the average rotation (rotation around the long axis, AR) and disk summation (parallel short axis cuts, DS) methods. Volumes of these lesions were also measured in vitro by water submersion. They ranged from 0.20 mL to 24 mL (mean +/- SD = 8.07 +/- 9.21 mL). Both 3-D TEE AR and 3-D TEE DS calculated volumes correlated excellently with in vitro measured volumes (r = 1.00 and r = 0.98, respectively, p = < 0.0001). The correlation between 3-D TEE AR and 3-D TEE DS calculated volumes was also excellent (r = 0.98, p = < 0.0001). In conclusion, the volume assessments by 3-D TEE of intracardiac mass lesions correlated well with in vitro measured volumes of surgical specimens. This technique may prove to be valuable in further defining intracardiac pathology and is a further advancement toward the application of clinically useful 3-D echocardiography. (E-mail: nanda@uab.edu) (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1389 / 1393
页数:5
相关论文
共 50 条
  • [31] Three-dimensional transesophageal echocardiography of the atrial septal defects
    Francisco-Javier Roldán
    Jesús Vargas-Barrón
    Clara Vázquez-Antona
    Luis Muñoz Castellanos
    Julio Erdmenger-Orellana
    Ángel Romero-Cárdenas
    Marco-Antonio Martínez-Ríos
    Cardiovascular Ultrasound, 6
  • [32] Live/Real Time Three-Dimensional Transesophageal Echocardiography
    Sudhakar, Selvin
    Khairnar, Prakash
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (01): : 103 - 111
  • [33] Transesophageal three-dimensional echocardiography in papillary muscle rupture
    Malhotra, S
    Nanda, NC
    McElderry, HT
    Thakur, AC
    Costa, F
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (06): : 603 - 604
  • [34] Validation of Semiautomated Quantification of Mitral Valve Regurgitation by Three-Dimensional Color Doppler Transesophageal Echocardiography
    Militaru, Sebastian
    Bonnefous, Odile
    Hami, Karima
    Langet, Helene
    Houard, Laura
    Allaire, Stephane
    Pouleur, Anne-Catherine
    Dianis, Scott
    This, Alexandre
    Beauloye, Christophe
    Vancraeynest, David
    Pasquet, Agnes
    Vanoverschelde, Jean-Louis
    Gerber, Bernhard L.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (03) : 342 - 354
  • [35] Semi-automated Detection and Quantification of Aortic Atheromas from Three-Dimensional Transesophageal Echocardiography
    Piazzese, Concetta
    Tsang, Wendy
    Sotaquira, Miguel
    Lang, Roberto M.
    Caiani, Enrico G.
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 13 - 16
  • [36] Theoretical estimation and measurement of accuracy and variability in Left ventricular volume and mass quantification using Three-Dimensional Echocardiography
    Nadkarni, SK
    Boughner, DR
    Drangova, M
    Fenster, A
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 673 - 675
  • [37] VOLUME MEASUREMENT OF DILATED RIGHT VENTRICLE BY THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN CONGENITAL HEART DISEASE
    Kishiki, Kanako
    Inage, Akio
    Horita, Ryo
    Terada, Mai
    Izumi, Yuki
    Mizuno, Naokazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 642 - 642
  • [38] Interventional three-dimensional echocardiography: Using real-time three-dimensional echocardiography to guide and evaluate intracardiac therapies
    Gill, Edward A.
    Liang, David H.
    CARDIOLOGY CLINICS, 2007, 25 (02) : 335 - +
  • [39] Visualization and quantification of myocardial mass at risk using three-dimensional contrast echocardiography
    Kasprzak, JD
    Vletter, WB
    Roelandt, JRTC
    van Meegen, JR
    Johnson, R
    Ten Cate, FJ
    CARDIOVASCULAR RESEARCH, 1998, 40 (02) : 314 - 321
  • [40] Real Time Three-Dimensional Echocardiography Evaluation of Intracardiac Masses
    Zaragosa-Macias, Elisa
    Chen, Michael A.
    Gill, Edward A.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (02): : 207 - 219