Capillary neutron optics for prompt-gamma activation analysis

被引:11
|
作者
ChenMayer, HH [1 ]
Sharov, VA [1 ]
Mildner, DFR [1 ]
Downing, RG [1 ]
Paul, RL [1 ]
Lindstrom, RM [1 ]
Zeissler, CJ [1 ]
Xiao, QF [1 ]
机构
[1] XRAY OPT SYST INC, ALBANY, NY 12205 USA
关键词
LENS;
D O I
10.1007/BF02109890
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A neutron lens has been constructed to focus cold neutrons from the exit of a Ni-58 neutron guide, which delivers a beam to the Prompt-Gamma Activation Analysis (PGAA) station at the MST Cold Neutron Research Facility. The lens compresses a neutron beam of cross section 50 mm x 45 mm onto a focal spot of diameter 0.53 mm (fwhm) with an average gain of 80 in neutron current density. PGAA measurements have been performed to demonstrate the enhanced sensitivity and detection limits for various elements and the spatial resolution in one transverse dimension. For the two test particles (a gadolinium glass bead and cadmium metal of sizes less than 0.5 mm), the gain in the gamma-count rate with the lens is a factor of 60, and the detection limit is improved by a factor of 20. The system can be used for two-dimensional mapping of samples on a sub-millimeter scale to complement other analytical techniques such as neutron depth profiling (NDP).
引用
收藏
页码:141 / 145
页数:5
相关论文
共 50 条
  • [41] Influence of the effective mass on the relative neutron density distribution inside a large sample in prompt-gamma neutron activation analysis
    Blaauw, M.
    Degenaar, I. H.
    de Goeij, J. J. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (03) : 761 - 764
  • [42] MACHINATIONS - WHY BORON - PROMPT-GAMMA NEUTRON-ACTIVATION ANALYSIS AT MCMASTER-NUCLEAR-REACTOR
    HIGGINS, MD
    GEOSCIENCE CANADA, 1984, 11 (04) : 210 - 211
  • [43] Compositional studies of functional orthodontic archwires using prompt-gamma activation analysis at a pulsed neutron source
    Tian, Kun V.
    Festa, Giulia
    Szentmiklosi, Laszlo
    Maroti, Boglarka
    Arcidiacono, Laura
    Lagana, Giuseppina
    Andreani, Carla
    Licoccia, Silvia
    Senesi, Roberto
    Cozza, Paola
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (07) : 1420 - 1427
  • [44] Prompt-gamma activation analysis using thek0 approach
    G. L. Molnár
    Zs. Révay
    R. L. Paul
    R. M. Lindstrom
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 234 : 21 - 26
  • [45] Prompt-gamma activation analysis using the k0 approach
    Molnar, GL
    Revay, Z
    Paul, RL
    Lindstrom, RM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 21 - 26
  • [46] AMERICIUM-BERYLLIUM + PLUTONIUM-BERYLLIUM NEUTRON SOURCE RELATIVE EFFECTIVENESS IN PROMPT-GAMMA NEUTRON-ACTIVATION ANALYSIS
    JORDAN, ED
    SCHIERLI.HE
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1964, 15 (07): : 427 - &
  • [47] COHN analysis: Body composition measurements based on the associated particle imaging and prompt-gamma neutron activation analysis techniques
    Ellis, K. J.
    Shypailo, R. J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 79 - 83
  • [48] COHN analysis: Body composition measurements based on the associated particle imaging and prompt-gamma neutron activation analysis techniques
    K. J. Ellis
    R. J. Shypailo
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 79 - 83
  • [49] Correction for neutron self-shielding in large-sample prompt-gamma neutron activation analysis - Determination of macroscopic neutron cross sections
    Degenaar, IH
    Blaauw, M
    de Goeij, JJM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 257 (03) : 467 - 470
  • [50] DETERMINATION OF BORON IN FOOD AND BIOLOGICAL REFERENCE MATERIALS BY NEUTRON-CAPTURE PROMPT-GAMMA ACTIVATION
    ANDERSON, DL
    CUNNINGHAM, WC
    MACKEY, EA
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (04): : 554 - 558