Statistical reconstruction for x-ray CT systems with non-continuous detectors

被引:18
|
作者
Zbijewski, Wojciech [1 ]
Defrise, Michel
Viergever, Max A.
Beekman, Freek J.
机构
[1] UMC Utrecht, Image Sci Inst, Dept Nucl Med, NL-3584 CG Utrecht, Netherlands
[2] UMC Utrecht, Rudolf Magnus Inst Neurosci, NL-3584 CG Utrecht, Netherlands
[3] AZ Vrije Univ Brussel, Univ Hosp, Dept Nucl Med, B-1090 Brussels, Belgium
[4] UMC Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 02期
关键词
D O I
10.1088/0031-9155/52/2/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We analyse the performance of statistical reconstruction (SR) methods when applied to non-continuous x-ray detectors. Robustness to projection gaps is required in x-ray CT systems with multiple detector modules or with defective detector pixels. In such situations, the advantage of statistical reconstruction is that it is able to ignore missing or faulty pixels and that it makes optimal use of the remaining line integrals. This potentially obviates the need to fill the sinogram discontinuities by interpolation or any other approximative preprocessing techniques. In this paper, we apply SR to cone beam projections of (i) a hypothetical modular detector micro-CT scanner and of (ii) a system with randomly located defective detector elements. For the modular-detector system, SR produces reconstruction volumes free of noticeable gap-induced artefacts as long as the location of detector gaps and selection of the scanning range provide complete object sampling in the central imaging plane. When applied to randomly located faulty detector elements, SR produces images free of substantial ring artefacts even for cases where defective pixels cover as much as 3% of the detector area.
引用
收藏
页码:403 / 418
页数:16
相关论文
共 50 条
  • [1] Statistical reconstruction for X-ray micro-CT systems with noncontinuous detectors.
    Zbijewski, Wojciech
    Beekman, Freek J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2323 - 2326
  • [2] X-ray reflectivity of multilayers with non-continuous interfaces
    Rafaja, D
    Fuess, H
    Simek, D
    Kub, J
    Zweck, J
    Vacínová, J
    Valvoda, V
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2002, 14 (21) : 5303 - 5314
  • [3] Quantifying the Importance of the Statistical Assumption in Statistical X-ray CT Image Reconstruction
    Xu, Jingyan
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 61 - 73
  • [4] Multispectral X-ray CT - Multivariate Statistical Analysis for Efficient Reconstruction
    Kheirabadi, Mina
    Mustafa, Wail
    Lyksborg, Mark
    Olsen, Ulrik Lund
    Dahl, Anders Bjorholm
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [5] Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT
    Srivastava, Somesh
    Fessler, Jeffrey A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1551 - 1555
  • [6] A NEW STATISTICAL IMAGE RECONSTRUCTION ALGORITHM FOR POLYENERGETIC X-RAY CT
    Abella, Monica
    Fessler, Jeffrey A.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 165 - 168
  • [7] Statistical reconstruction for x-ray computed tomography using energy-integrating detectors
    Lasio, Giovanni M.
    Whiting, Bruce R.
    Williamson, Jeffrey F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08): : 2247 - 2266
  • [8] Detectors for the X-Ray testing systems
    Ayzenshtat, GI
    Vilisova, MD
    Lelekov, MA
    Ivashchenko, AI
    Mokeev, DY
    Porokhovnichenko, LP
    Tolbanov, OP
    Shapoval, LG
    SIBCON-2005: IEEE International Siberian Conference on Control and Communications, 2005, : 72 - 77
  • [9] Advanced x-ray detectors for volumetric CT
    Deych, Ruvin
    Dolazza, Enrico
    2007 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2007, : 115 - +
  • [10] Statistical modeling challenges in model-based reconstruction for X-ray CT
    Zhang, Ruoqiao
    Chang, Aaron
    Thibault, Jean-Baptiste
    Sauer, Ken
    Bouman, Charles
    COMPUTATIONAL IMAGING XI, 2013, 8657