Four-Dimensional Computed Tomography Scan Utility in Parathyroidectomy for Primary Hyperparathyroidism With Low Baseline Intact Parathyroid Hormone

被引:18
|
作者
Rameau, Anais [1 ]
Eng, Soo [2 ]
Vu, Joseph [2 ]
Saket, Ramin [3 ]
Jun, Peter [3 ]
Friduss, Michael [1 ,4 ]
机构
[1] Stanford Univ, Dept Otolaryngol Head & Neck Surg, 801 Welch Rd, Stanford, CA 94305 USA
[2] Kaiser Permanente Hosp, Dept Endocrinol, Santa Clara, CA USA
[3] Kaiser Permanente Hosp, Neuroradiol Div, Santa Clara, CA USA
[4] Kaiser Permanente Hosp, Dept Otolaryngol Head & Neck Surg, Santa Clara, CA USA
来源
LARYNGOSCOPE | 2017年 / 127卷 / 06期
关键词
Endocrine; parathyroid; preoperative workup; parathyroid surgery; imaging; PREOPERATIVE LOCALIZATION; ECONOMIC-ANALYSIS; CT; ULTRASONOGRAPHY; SESTAMIBI; ADENOMAS; COST; IMPACT; 4D-CT;
D O I
10.1002/lary.26201
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: The prevalence of multiglandular disease (MGD) of the parathyroid has been reported to be higher in patients with primary hyperparathyroidism and low baseline intact parathyroid hormone (PTH) levels (<100 pg/mL). Low baseline PTH is associated with lower localization rate and positive predictive value with both preoperative sestamibi and ultrasound. This study sought to evaluate our experience with four-dimensional computed tomography (4D-CT) for the localization of abnormal parathyroid glands, including MGD, in patients with low baseline intact PTH (LBiPTH). Study Design: A single institution case series. Methods: A case series of patients with primary hyperparathyroidism with low baseline PTH or an inconclusive sestamibi, who underwent surgery with a single surgeon from April 2012 to June 2015 following 4D-CT to help with abnormal gland localization. Results: We identified 14 patients who underwent a 4D-CT in the setting of primary hyperparathyroidism and LBiPTH. A sestamibi scan had been ordered in 71% and was inconclusive in all cases. No ultrasound was performed. In all patients, 4D-CT was 84.6% sensitive in localizing abnormal glands, yielding a positive predictive value of 91.7%. Overall, 42.9% of patients had evidence of MGD, and 4D-CT detected 83.3% of MGD cases. A focused unilateral exploration was performed in 28.6% of cases, and a four-gland exploration was performed in all remaining patients. Conclusions: In patients with hypercalcemia and LBiPTH, with higher likelihood of MGD and of inconclusive results on sestamibi, 4D-CT may be a superior modality for localizing smaller adenoma or multiple hypercellular glands. This may allow for improved interpretation of intraoperative PTH results, and in a minority of cases, a focused parathyroid exploration.
引用
收藏
页码:1476 / 1482
页数:7
相关论文
共 50 条
  • [41] Utility of Intraoperative Parathyroid Hormone Monitoring in Patients with Multiple Endocrine Neoplasia Type 1-Associated Primary Hyperparathyroidism Undergoing Initial Parathyroidectomy
    Naris Nilubol
    Allison B. Weisbrod
    Lee S. Weinstein
    William F. Simonds
    Robert T. Jensen
    Giao Q. Phan
    Marybeth S. Hughes
    Steven K. Libutti
    Stephen Marx
    Electron Kebebew
    World Journal of Surgery, 2013, 37 : 1966 - 1972
  • [42] Utility of Intraoperative Parathyroid Hormone Monitoring in Patients with Multiple Endocrine Neoplasia Type 1-Associated Primary Hyperparathyroidism Undergoing Initial Parathyroidectomy
    Nilubol, Naris
    Weisbrod, Allison B.
    Weinstein, Lee S.
    Simonds, William F.
    Jensen, Robert T.
    Phan, Giao Q.
    Hughes, Marybeth S.
    Libutti, Steven K.
    Marx, Stephen
    Kebebew, Electron
    WORLD JOURNAL OF SURGERY, 2013, 37 (08) : 1966 - 1972
  • [43] Reconstitution of internal target volumes by combining four-dimensional computed tomography and a modified slow computed tomography scan in stereotactic body radiotherapy planning for lung cancer
    Seong Soon Jang
    Gil Ja Huh
    Suk Young Park
    Po Song Yang
    Hae Nam Chung
    Jae Hyuk Seo
    Ji Chan Park
    Young Jun Yang
    Eun Youn Cho
    Radiation Oncology, 9
  • [44] Reconstitution of internal target volumes by combining four-dimensional computed tomography and a modified slow computed tomography scan in stereotactic body radiotherapy planning for lung cancer
    Jang, Seong Soon
    Huh, Gil Ja
    Park, Suk Young
    Yang, Po Song
    Chung, Hae Nam
    Seo, Jae Hyuk
    Park, Ji Chan
    Yang, Young Jun
    Cho, Eun Youn
    RADIATION ONCOLOGY, 2014, 9
  • [45] The utility of 4-dimensional computed tomography for preoperative localization of primary hyperparathyroidism in patients not localized by sestamibi or ultrasonography
    Day, Kristopher M.
    Elsayed, Mohammad
    Beland, Michael D.
    Monchik, Jack M.
    SURGERY, 2015, 157 (03) : 534 - 539
  • [46] Are 99mTC-Sestamibi Single Photon Emission Computed Tomography Scan Results Associated to the Parathyroid Cell Type in Primary Hyperparathyroidism?
    Romero-Velez, Gustavo
    Noureldine, Salem I.
    Rahman, Mobeen
    Bena, James F.
    Burneikis, Talia
    Jin, Judy
    JOURNAL OF SURGICAL RESEARCH, 2024, 293 : 517 - 524
  • [47] Original Four-dimensional computed tomography (4D-CT) for preoperative parathyroid localization: A good study but are we using it?
    Kuo, Lindsay E.
    Bird, Sarah H.
    Lubitz, Carrie C.
    Pandian, T. K.
    Parangi, Sareh
    Stephen, Antonia E.
    AMERICAN JOURNAL OF SURGERY, 2022, 223 (04): : 694 - 698
  • [48] Interobserver variability in the delineation of the primary lung cancer and lymph nodes on different four-dimensional computed tomography reconstructions
    Mercieca, Susan
    Belderbos, Jose S. A.
    De Jaeger, Katrien
    Schinagl, Dominic A. X.
    Van Zijp, Noelle van der Voort
    Pomp, Jacqueline
    Theuws, Jacqueline
    Khalifa, Jonathan
    van de Vaart, Paul
    van Herk, Marcel
    RADIOTHERAPY AND ONCOLOGY, 2018, 126 (02) : 325 - 332
  • [49] Correlation of primary middle and distal esophageal cancers motion with surrounding tissues using four-dimensional computed tomography
    Wang, Wei
    Li, Jianbin
    Zhang, Yingjie
    Shao, Qian
    Xu, Min
    Guo, Bing
    Shang, Dongping
    ONCOTARGETS AND THERAPY, 2016, 9 : 3705 - 3710
  • [50] Four-Dimensional Computed Tomography Scan Analysis of Liver Tumor Motion Treated With Abdominal Compression During Stereotactic Treatment of Liver
    Zhao, Y.
    Tang, Y.
    Liu, W., Jr.
    Li, N.
    Song, Y.
    Wang, S.
    Liu, Y.
    Fang, H.
    Lu, N.
    Tang, Y.
    Qi, S.
    Yang, Y.
    Chen, B.
    Li, Y.
    Jin, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E543 - E544