Bilateral C1-C2 Claw for Atlantoaxial Instability

被引:3
|
作者
Hanimoglu, Hakan [1 ]
Hanci, Lale [2 ]
Kaynar, Mehmet Yasar [1 ]
Hanci, Murat [1 ]
机构
[1] IU Cerrahpasa Med Fac, Dept Neurosurg, Istanbul, Turkey
[2] Bone & Joint Disorders Res & Educ Hosp, Istanbul, Turkey
关键词
Atlantoaxial instability; Claw systems; Transverse connector; TRANSARTICULAR SCREW FIXATION; ROTATION; PLATE;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Atlantoaxial stability can be achieved by laminar hook systems via posterior approach. This technique is much more safer than using screws. We presented our experience with the C1-C2 claw procedure. METHODS and MATERIAL: Seven patients with atlantoaxial instability were operated by using C1 and C2 hooks, rods and transverse connector at Neurosurgery Clinic of Istanbul University Cerrahpasa Medical Faculty between the years 2005 and 2008. RESULTS: Satisfactory stabilization was achieved in all patients. Operative complication or instrumentation failure was not observed. CONCLUSIONS: C1-C2 claw is a safe technique and adequate stabilization is achieved with the use of a transverse connector.
引用
收藏
页码:345 / 348
页数:4
相关论文
共 50 条
  • [31] Intraspinal synovial cyst communicating with the C1-C2 facet joints and subarachnoid space associated with rheumatoid atlantoaxial instability
    Morio, Y
    Yoshioka, T
    Nagashima, H
    Hagino, H
    Teshima, R
    SPINE, 2003, 28 (23) : E492 - E495
  • [32] C1-C2 Fixation for Chiari with Syringomyelia Associated with Atlantoaxial Instability, Atlantooccipital Assimilation and an Anomalous Vertebral Artery Course
    Jain, Chirag
    Pruthi, Nupur
    WORLD NEUROSURGERY, 2024, 191 : 37 - 38
  • [33] Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques
    Claybrooks, Roderick
    Kayanja, Mark
    Milks, Ryan
    Benzel, Edward
    SPINE JOURNAL, 2007, 7 (06): : 682 - 688
  • [34] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Comment
    McCormick, PC
    NEUROSURGERY, 1998, 43 (02) : 280 - 280
  • [35] MENISCUS-LIKE SYNOVIAL FOLD IN THE ATLANTOAXIAL (C1-C2) JOINT
    CHANG, H
    FOUND, EM
    CLARK, CR
    GOEL, VK
    GANG, CS
    JOURNAL OF SPINAL DISORDERS, 1992, 5 (02): : 227 - 231
  • [36] ATLANTOAXIAL (C1-C2) FACET JOINT OSTEOARTHRITIS - A DISTINCTIVE CLINICAL SYNDROME
    HALLA, JT
    HARDIN, JG
    ARTHRITIS AND RHEUMATISM, 1987, 30 (05): : 577 - 582
  • [37] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Reply
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1999, 44 (03) : 688 - 689
  • [38] Safety Issues and Neurological Improvement following C1-C2 Fusion using C1 Lateral Mass and C2 Pedicle Screw in Atlantoaxial Instability
    Kwan, M. K.
    Chan, C. Y. W.
    Kwan, T. C. C.
    Gashi, Y. N.
    Saw, L. B.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2010, 4 (02) : 17 - 22
  • [39] Transarticular screws in the management of C1-C2 instability in children
    Reilly, Christopher W.
    Choit, Rachel L.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2006, 26 (05) : 582 - 588
  • [40] Clinical outcome of posterior C1-C2 pedicle screw fixation and fusion for atlantoaxial instability: A retrospective study of 86 patients
    Zheng, Yonghong
    Hao, Dingjun
    Wang, Biao
    He, Baorong
    Hu, Huimin
    Zhang, Haiping
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 32 : 47 - 50