The effect of interfraction prostate motion on IMRT plans: a dose-volume histogram analysis using a Gaussian error function model

被引:9
|
作者
Chow, James C. L. [1 ,2 ,3 ,4 ]
Jiang, Runqing [5 ]
Markel, Daniel
机构
[1] Univ Hlth Network, Dept Radiat Phys, Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[4] Univ Waterloo, Dept Phys, Waterloo, ON N2L 3G1, Canada
[5] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
来源
关键词
dose-volume histogram; prostate IMRT; internal organ motion; error function and model fitting; ORGAN MOTION; INTRAFRACTION MOTION; RADIOTHERAPY; OPTIMIZATION; CANCER; DEFORMATION; IRRADIATION; CARCINOMA; RADIATION; THERAPY;
D O I
10.1120/jacmp.v10i4.3055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Gaussian error function model, containing pairs of error and complementary error functions, was used to carry out cumulative dose-volume histogram (cDVH) analysis on prostate intensity-modulated radiation therapy (IMRT) plans with interfraction prostate motion. Cumulative DVHs for clinical target volumes (CTVs) shifted in the anterior-posterior directions based on a 7-beam IMRT plan were calculated and modeled using the Pinnacle(3) treatment planning system and a Gaussian error function, respectively. As the parameters in the error function model (namely, a, b and c) were related to the shape of the cDVH curve, evaluation of cDVHs corresponding to the prostate motion based on the model parameters becomes possible, as demonstrated in this study. It was found that deviations of the cDVH for the CTV were significant, when the CTV-planning target volume (PTV) margin was underestimated in the anterior-posterior directions. This was especially evident in the posterior direction for a patient with relatively small prostate volume (39 cm(3)). Analysis of the cDVH for the CTV shifting in the anterior-posterior directions using the error function model showed that parameters a(1,2), which were related to the maximum relative volume of the cDVH, changed symmetrically when the prostate was shifted in the anterior and posterior directions. This change was more significant for the larger prostate. For parameters b related to the slope of the cDVH, b(1,2) changed symmetrically from the isocenter, when the CTV was within the PTV. This was different from parameters c (c(1,2) are related to the maximum dose of the cDVH), which did not vary significantly with the prostate motion in the anterior-posterior directions and prostate volume. Using the patient data, this analysis validated the error function model, and further verified the clinical application of this mathematical model on treatment plan evaluations.
引用
收藏
页码:79 / 95
页数:17
相关论文
共 50 条
  • [11] Analysis of dose-volume histogram using Fourier transformation
    Das, Indra J.
    Khan, Ahtesham U.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4768 - S4770
  • [12] Key Anatomical Factors Influencing OAR Dose-Volume Distribution in Prostate IMRT Plans
    Yuan, L.
    Ge, Y.
    Li, T.
    Zhu, X.
    Yin, F.
    Wu, Q.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [13] Correlating Dose-Volume Histogram Results with Overlapping Volume of Organ-At-Risk and Planning Target Volume for Prostate IMRT
    Ma, T.
    Wang, I. Z.
    MEDICAL PHYSICS, 2014, 41 (06) : 349 - +
  • [14] Dose-volume analysis of rectal hemorrhage after IMRT for prostate cancer
    Yasui, K.
    Nakamura, D.
    Egawa, A.
    Yamazaki, T.
    Hayashi, N.
    Takehara, K.
    Sakai, H.
    Uetani, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S676 - S676
  • [15] Estimation of DVH Variation for PTV Due to Interfraction Organ Motion in Prostate VMAT Using Gaussian Error Function
    Lewis, C.
    Jiang, R.
    Chow, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3302 - 3302
  • [16] Real-time beam monitoring for error detection in IMRT plans and impact on dose-volume histograms
    Marrazzo, Livia
    Arilli, Chiara
    Pasler, Marlies
    Kusters, Martijn
    Canters, Richard
    Fedeli, Luca
    Calusi, Silvia
    Casati, Marta
    Talamonti, Cinzia
    Simontacchi, Gabriele
    Livi, Lorenzo
    Pallotta, Stefania
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (03) : 243 - 254
  • [17] Evaluation of different set-up error corrections on dose-volume metrics in prostate IMRT using CBCT images
    Hirose, Yoshinori
    Nakamura, Mitsuhiro
    Tomita, Tsuneyuki
    Kitsuda, Kenji
    Notogawa, Takuya
    Miki, Katsuhito
    Nakamura, Kiyonao
    Ishigaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) : 966 - 975
  • [18] Error correction of dose-volume parameters by using the relation between the rectum volume and rectum shape changes for prostate cancer treatment plans
    Hoogeman, MS
    Koper, PCM
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S216 - S216
  • [19] Evaluation and ranking of lung IMRT treatment plans using a dose-volume biological-response index
    Miften, M
    Das, S
    Shafman, T
    Marks, L
    MEDICAL PHYSICS, 2002, 29 (06) : 1293 - 1293
  • [20] A dose-volume histogram analysis of the seminal vesicles in men treated with conformal radiotherapy to 'prostate alone'
    Parker, C
    Haycocks, T
    Bayley, A
    Alasti, H
    Warde, P
    Catton, C
    CLINICAL ONCOLOGY, 2002, 14 (04) : 298 - 302