A New Normal Mode dv/dt Filter With Resistor Failure Detection Circuit

被引:0
|
作者
Baumgardner, Mark [1 ]
Swamy, Mahesh [1 ]
机构
[1] Yaskawa Amer Inc, Waukegan, IL 60085 USA
关键词
dv/dt filter; long lead length drive application; resistor failure detection scheme; motor insulation breakdown;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Insulated Gate Bipolar Transistors (IGBTs) will soon be replaced by wide band gap devices (SiC and GaN) as the choice for power semi-conductor switch in Voltage Source Inverters. These devices have extremely fast rise time and fall time compared to IGBT devices. The high dv/dt of PWM outputs create excessive voltage stress in the insulation system of AC motors due to voltage reflection issues associated with motors at large distances from the drive. In many oil field applications, the distance between the motor and the Variable Frequency Drive (VFD) approaches 300m. In walking rig applications, it is common to use multiple smaller sized conductors per phase, bunched together, to achieve the desired ampacity. This practice results in higher than usual value of the cable parasitic capacitance. Traditional dv/dt filters used for mitigating over-voltage at motor terminals, have been found to be inadequate in reducing the over voltage at the motor terminals in such oil field installations. The damping resistor often experiences high voltage and gets damaged. A new dv/dt filter suitable for use with high power AC motors at distances nearing 300m with a built-in resistor failure detection circuit is proposed here. Test results are given to demonstrate its efficacy.
引用
收藏
页数:7
相关论文
共 26 条
  • [22] A Quad-Slope 70V GaN Gate Driver with Integrated Three- Mode Level Shifter for Enhanced Negative Voltage Tolerance, dV/dt Detection and Double-Edge Self-Triggered Delay Compensation
    Liu, Tianqi
    Gao, Qiang
    Martins, Rui P.
    Lu, Yan
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 1141 - 1145
  • [23] New Measurement Fechnique for Modular Multilevel Converter with IGBT Open-Circuit Failure Detection and. Tolerance Control for Three-Level Submodule
    Sallam, Ahmed
    Hamdy, Ragi A. R.
    Moustafa, Mohamed M. Zakaria
    Hossam-Eldin, Ahmed
    2016 IEEE INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2016, : 452 - 457
  • [24] Granular-bed filtration assisted by filter-cake formation 1. Exploiting a new mode of soil failure for renewal of filtration surfaces in a panel bed
    Lee, KC
    Pfeffer, R
    Squires, AM
    POWDER TECHNOLOGY, 2005, 155 (01) : 5 - 16
  • [25] Comparison of IGBT short-circuit failure "ohmic mode": Epoxy molded package versus silicone gel module for new fail-safe and interruptible power converters
    Richardeau, Frederic
    Dou, Zhifeng
    Sarraute, Emmanuel
    Blaquiere, Jean-Marc
    Flumian, Didier
    MICROELECTRONICS RELIABILITY, 2011, 51 (9-11) : 1919 - 1926
  • [26] Complete short-circuit failure mode properties and comparison based on IGBT standard packaging. Application to new fault-tolerant inverter and interleaved chopper with reduced parts count
    Richardeau, Frederic
    Dou, Zhifeng
    Blaquiere, Jean-Marc
    Sarraute, Emmanuel
    Flumian, Didier
    Mosser, Franck
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,