Determination of 242Pu abundance in plutonium samples using self-fluorescent X-ray emission

被引:0
|
作者
Berndt, Reinhard [1 ]
Mortreau, Patricia [1 ]
机构
[1] European Commiss, Joint Res Ctr, Ispra, Italy
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2019年 / 940卷
关键词
Plutonium isotopic composition; Pu-242; Self-fluorescence; Non destructive assays; Nuclear safeguards; High resolution gamma spectrometry;
D O I
10.1016/j.nima.2019.04.075
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Non-destructive gamma spectrometric measurements of the isotopic composition of plutonium are routinely carried out in the framework of nuclear safeguards inspections. High-resolution spectra of Pu obtained from planar Ge detectors are de-convoluted by means of special codes such as MGA or FRAM and these results are then applied when determining the total plutonium mass using neutron coincidence measurement techniques. The radiation emission of Pu-242 is so weak that its abundance cannot be measured directly; hence isotopic correlations are utilized to estimate it in low and medium burn-up Pu material. The present work investigates the feasibility of determining the total Pu/Am ratio, exploiting X-ray fluorescence lines present in the plutonium spectrum. Combining the total Pu/Am ratio with individual Pu isotopic ratios to Am-241 then allows an estimate of the Pu-242 to be made. To this end, reference samples of plutonium, with an Am-241 content comprised between 5 and 7 %, were measured using a planar germanium detector. The spectra were processed using MGA followed by quantification of the X-ray fluorescence peak of Americium, and then further calculations, including MCNP simulations. The conclusion of the present work is that, when the americium content of the sample is high enough to produce an Am K-alpha 1 line which can be exploited, it is possible to indirectly determine the Pu-242 abundance by analysing the X-ray fluorescent lines present in the plutonium gamma spectrum, thus raising the prospect to apply this method to cases for which the algorithms based on empirical correlations cannot be applied.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [41] X-Ray Fluorescence and Atomic Emission Determination of Cobalt in Water Using Polyurethane Foam Sorbents
    Oskolok, K., V
    Monogarova, O., V
    MOSCOW UNIVERSITY CHEMISTRY BULLETIN, 2011, 66 (03) : 179 - 183
  • [42] Metal determination and quantification in biological material using particle-induced X-ray emission
    Bertrand, M
    Weber, G
    Schoefs, B
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (04) : 254 - 262
  • [43] Determination of the Content of Hf in Zirconium Alloys with using a Wide Band X-Ray Emission Filter
    Omelnyk, O. P.
    Levenets, V. V.
    Lonin, A. Yu
    Shevchenko, I., V
    Shchur, A. O.
    METHODS AND OBJECTS OF CHEMICAL ANALYSIS, 2018, 13 (04): : 153 - 159
  • [44] X-ray fluorescence spectrometry and quantitative analysis of films using bulk samples - Application to the determination of aerosols
    deChateaubourg, P
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C4): : 667 - 674
  • [45] Direct determination of Na in lubricants by X-ray fluorescence spectrometry using thin-film samples
    Zhang, Yueping
    Fenxi Yiqi/Analytical Instrumentation, 2002, (03):
  • [46] Quantitative reconstruction of PIXE-tomography data for thin samples using GUPIX X-ray emission yields
    Univ. Bordeaux, CENBG, UMR 5797, Gradignan
    F-33170, France
    不详
    F-33170, France
    不详
    F-33608, France
    不详
    WC1E 6BT, United Kingdom
    不详
    2685-066, Portugal
    不详
    ON
    N1G 2W1, Canada
    Nucl Instrum Methods Phys Res Sect B, (92-99):
  • [47] Quantitative reconstruction of PIXE-tomography data for thin samples using GUPIX X-ray emission yields
    Michelet, C.
    Barberet, Ph
    Deves, G.
    Bouguelmouna, B.
    Bourret, S.
    Delville, M. -H.
    Le Trequesser, Q.
    Gordillo, N.
    Beasley, D. G.
    Marques, A. C.
    Farau, R.
    Toko, B. R.
    Campbell, J.
    Maxwell, J.
    Motetto, Ph
    Seznec, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 348 : 92 - 99
  • [48] Determination of the Effective Detector Area of an Energy-Dispersive X-Ray Spectrometer at the Scanning Electron Microscope Using Experimental and Theoretical X-Ray Emission Yields
    Procop, Mathias
    Hodoroaba, Vasile-Dan
    Terborg, Ralf
    Berger, Dirk
    MICROSCOPY AND MICROANALYSIS, 2016, 22 (06) : 1360 - 1368
  • [49] Trace element determination in tomato puree using particle induced X-ray emission and Rutherford backscattering
    E. Romero-Dávila
    J. Miranda
    Journal of Radioanalytical and Nuclear Chemistry, 2004, 262 : 355 - 362
  • [50] Trace element determination in tomato puree using particle induced X-ray emission and Rutherford backscattering
    Romero-Dávila, E
    Miranda, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 262 (02) : 355 - 362