Heterologous strategy enhancing the sensitivity of the fluorescence polarization immunoassay of clinafloxacin in goat milk

被引:22
|
作者
Chen, Jiahong [2 ]
Shanin, Ilya A. [1 ,3 ]
Lv, Shuwei [2 ]
Wang, Qiang [4 ]
Mao, Chuanbin [5 ]
Xu, Zhenlin [2 ]
Sun, Yuanming [2 ]
Wu, Qing [2 ]
Eremin, Sergei A. [1 ,3 ]
Lei, Hongtao [2 ]
机构
[1] Moscow MV Lomonosov State Univ, Fac Chem, Leninskie Gory 1,Bldg 3, Moscow 119991, Russia
[2] South China Agr Univ, Guangdong Prov Engn & Tech Res Ctr Food Safety De, Guangdong Prov Key Lab Food Qual & Safety, Guangzhou 510642, Guangdong, Peoples R China
[3] Russian Acad Sci, AN Bakh Biochem Inst, Moscow 119071, Russia
[4] Chinese Acad Fishery Sci, South China Sea Fisheries Res Inst, Guangzhou 510300, Guangdong, Peoples R China
[5] Univ Oklahoma, Dept Chem & Biochem, Stephenson Life Sci Res Ctr, Norman, OK 73019 USA
基金
俄罗斯基础研究基金会;
关键词
heterologous; clinafloxacin; fluorescence polarization immunoassay; goat milk; FLUOROQUINOLONE; PESTICIDES; HERBICIDE; EFFICACY; SAMPLES; BOVINE; ELISA; ASSAY;
D O I
10.1002/jsfa.7228
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
BACKGROUNDClinafloxacin is used for the treatment of disease in food-producing animals, e.g. Brucella melitensis, which often occurs in goats; however, the clinafloxacin residue in goat milk may harm human health and result in the development of drug-resistant bacterial strains or allergies. Despite this, there is not a rapid, sensitive and accurate analytical method in goat milk for rapid screening or monitoring purposes. RESULTSOne homologous and five heterologous tracers were designed and compared for fluorescence polarization immunoassay (FPIA) optimization. Based on the combination of a heterologous tracer (PAZ-FITC, synthesized with pazufloxacin and FITC) and the antibody against clinafloxacin, a highly sensitive FPIA was established for the detection of clinafloxacin residue in goat milk for the first time. The IC50 value was 29.3 mu g L-1 for clinafloxacin in the heterologous format - six times lower than that of the combination of the homologous tracers and the antibody. The recoveries ranged from 86.8% to 104.5%, with the relative standard deviation ranging from 4.1% to 7.2%. Validation by high-performance liquid chromatography (HPLC) confirmed that the results obtained from the proposed FPIA were in agreement with those of HPLC. CONCLUSIONThis proposed heterologous strategy for enhanced FPIA is sensitive and rapid enough for the high-throughput detection of clinafloxacin residue in goat milk. (c) 2015 Society of Chemical Industry
引用
收藏
页码:1341 / 1346
页数:6
相关论文
共 25 条
  • [21] Dual-assist heterologous antigens screening: An effective strategy to improve the sensitivity of lateral flow immunoassay
    Chen, Zhenzhen
    Chen, Jiawei
    Zhang, Gan
    Xiao, Xiaoyue
    Liu, Daofeng
    Lai, Weihua
    Peng, Juan
    Food Chemistry, 2025, 463
  • [22] A nanostructured aluminum oxide-based microfluidic device for enhancing immunoassay’s fluorescence and detection sensitivity
    Xiang Li
    Haocheng Yin
    Long Que
    Biomedical Microdevices, 2014, 16 : 771 - 777
  • [23] A nanostructured aluminum oxide-based microfluidic device for enhancing immunoassay's fluorescence and detection sensitivity
    Li, Xiang
    Yin, Haocheng
    Que, Long
    BIOMEDICAL MICRODEVICES, 2014, 16 (05) : 771 - 777
  • [24] Digitalis-like immunoreactive substances in maternal and umbilical cord plasma: A comparative sensitivity study of fluorescence polarization immunoassay and microparticle enzyme immunoassay
    Ijiri, Y
    Hayashi, T
    Kamegai, H
    Ohi, K
    Suzuki, K
    Kitaura, Y
    Takenaka, H
    THERAPEUTIC DRUG MONITORING, 2003, 25 (02) : 234 - 239
  • [25] Enhancing sensitivity in fluorescence measurements across an ultra-wide concentration range through optimizing combined-segments strategy
    Fu, Yuchao
    Jacobs, Daniel
    Tan, Shuiyi
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 423