Ni(II)-Based Metal-Organic Framework Anchored on Carbon Nanotubes for Highly Sensitive Non-Enzymatic Hydrogen Peroxide Sensing

被引:153
|
作者
Wang, Min-Qiang [1 ]
Zhang, Yan [1 ]
Bao, Shu-Juan [1 ]
Yu, Ya-Nan [1 ]
Ye, Cui [2 ]
机构
[1] Southwest Univ, Inst Clean Energy & Adv Mat, Fac Mat & Energy, Chongqing 400715, Peoples R China
[2] Southwest Univ, Coll Chem & Chem Engn, Key Lab Luminescent & Real Time Analyt Chem, Minist Educ, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
CNTs; Metal-Organic Framework; Nanocomposite; Peroxide; Sensing; DIRECT ELECTROCHEMISTRY; GRAPHENE OXIDE; MOFS;
D O I
10.1016/j.electacta.2015.12.199
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Recently metal-organic frameworks (MOFs) have attracted more attention in developing new electrochemical sensors due to their unique properties such as crystalline ordered structures, tunable pore sizes, large surface areas, chemical tenability and thermal stability. However, the direct application of single component MOFs in electrochemistry is limited owing to their poor electronic conductivity and inferior electrocatalytic ability. Herein, Ni(II)-Based metal-organic framework (Ni(II)-MOFs) was successfully anchored on carbon nanotubes (CNTs) by in situ solvothermal method for the first time. In the as-prepared composites, 2 similar to 3 nm MOFs nanoparticles homogeneously dispersed on conducting CNTs allowed for the MOFs nanoparticles to be wired up to a current collector through the underlying conducting CNTs. As the electrode materials of an non-enzymatic H2O2 biosensor, the Ni(II)-MOFs/CNTs exhibited excellent electrocatalytic performance including a wide linear detection range from 0.01 to 51.6 mmol L (1), low detection limit of 2.11 mu mol L (1) and very fast response of 2.5 s for H2O2 sensing. Most importantly, the stability and conductivity of Ni(II)-based MOFs is far higher than that of pure MOFs. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 50 条
  • [21] Spherical nickel boride nanoparticles anchored on a carbon nanofiber composite for efficient sensing of non-enzymatic hydrogen peroxide in biological samples
    Karthik, Raj
    Sukanya, Ramaraj
    Chavan, Prajakta R.
    Kumar, Deivasigamani Ranjith
    Lee, Jintae
    Shim, Jae-Jin
    APPLIED MATERIALS TODAY, 2024, 37
  • [22] Non-enzymatic electrochemical sensing of hydrogen peroxide based on polypyrrole/platinum nanocomposites
    Xing, Liwen
    Rong, Qinfeng
    Ma, Zhanfang
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 242 - 247
  • [23] Non-Enzymatic Amperometric Sensing of Hydrogen Peroxide Based on Vanadium Pentoxide Nanostructures
    Ghanei-Motlagh, Masoud
    Taher, Mohammad Ali
    Fayazi, Maryam
    Baghayeri, Mehdi
    Hosseinifar, AbduRahman
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B367 - B372
  • [24] Oriented growth of cross-linked metal-organic framework film on graphene surface for non-enzymatic electrochemical sensor of hydrogen peroxide in disinfectant
    Zhou, Yanli
    Li, Congming
    Hao, Yuanqiang
    Ye, Baoxian
    Xu, Maotian
    TALANTA, 2018, 188 : 282 - 287
  • [25] Ni-Based metal-organic framework derived Ni@C nanosheets on a Ni foam substrate as a supersensitive non-enzymatic glucose sensor
    Zhang, Li
    Ding, Yaru
    Li, Ranran
    Ye, Chen
    Zhao, Guangyu
    Wang, Yan
    JOURNAL OF MATERIALS CHEMISTRY B, 2017, 5 (28) : 5549 - 5555
  • [26] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite made from carbon nanotubes and molybdenum disulfide
    Lin, Yuping
    Chen, Xian
    Lin, Youxiu
    Zhou, Qian
    Tang, Dianping
    MICROCHIMICA ACTA, 2015, 182 (9-10) : 1803 - 1809
  • [27] Promoting non-enzymatic electrochemical sensing performance toward glucose by the integration of conducting polypyrrole with metal-organic framework
    Chen, Sihui
    Liu, Di
    Song, Na
    Wang, Ce
    Lu, Xiaofeng
    COMPOSITES COMMUNICATIONS, 2022, 30
  • [28] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite made from carbon nanotubes and molybdenum disulfide
    Yuping Lin
    Xian Chen
    Youxiu Lin
    Qian Zhou
    Dianping Tang
    Microchimica Acta, 2015, 182 : 1803 - 1809
  • [29] Facile fabrication and enhanced properties of copper-based metal organic framework incorporated with graphene for non-enzymatic detection of hydrogen peroxide
    Golsheikh, Amir Moradi
    Yeap, Guan-Yeow
    Yam, Fong Kwong
    Lim, Hwee San
    SYNTHETIC METALS, 2020, 260
  • [30] Non-enzymatic electrochemical sensing platform based on metal complex immobilized carbon nanotubes for glucose determination
    Sonkar, Piyush Kumar
    Ganesan, Vellaichamy
    John, S. Abraham
    Yadav, Dharmendra Kumar
    Gupta, Rupali
    RSC ADVANCES, 2016, 6 (108): : 107094 - 107103