Electrothermal vaporization from a graphite furnace was used in combination with inductively coupled plasma mass spectrometry (ICPMS) for the determination of Pt and Rh in environmental matrixes. Solid samples of tunnel dust, grass, and atmospheric aerosol collected on a cellulose filter could be analyzed directly, such that sample dissolution-which is not self-evident for the determination of platinum group metals-could be avoided. By heating the graphite furnace according to a multistep temperature program, spectral interferences were avoided, since a "dry" plasma was obtained, while "parent" ions such as Cu, Zn, and Pb, giving origin to interfering molecular ions, were vaporized during the thermal pretreatment step. For tunnel dust, the most demanding sample matrix, a mixture of HCl and HF was used as a modifier to stimulate the vaporization of matrix components during the thermal pretreatment step and, hence, to alleviate matrix-induced. analyte signal suppression during the actual vaporization step. Calibration was accomplished by means of single standard addition with an aqueous standard solution. The results obtained agreed within the experimental uncertainty with the corresponding reference values (certified values or results obtained using pneumatic nebulization ICPMS), while relative standard deviations of less than or equal to 15% were typical for both Pt and Rh. In all samples, a Pt/Rh ratio of approximately 6-8 was established. For a typical sample mass of 2 mg, limits of detection were 0.35 ng/gfor Pt and 0.05 ng/g for Rh.
引用
收藏
页码:6040 / 6048
页数:9
相关论文
共 50 条
  • [21] Determination of chromium by electrothermal vaporization inductively coupled plasma mass spectrometry
    Byrne, JP
    McIntyre, RSC
    Benyounes, ME
    Gregoire, DC
    Chakrabarti, CL
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 1997, 42 (04): : 95 - 101
  • [22] Vaporization and removal of silica for the direct analysis of geological materials by slurry sampling electrothermal vaporization-inductively coupled plasma-mass spectrometry
    Ben Younes, ME
    Grégoire, DC
    Chakrabarti, CL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) : 1703 - 1708
  • [23] Feasibility of As, Sb, Se and Te determination in coal by solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    Henn, Alessandra S.
    Flores, Erico M. M.
    Dressler, Valderi L.
    Mesko, Marcia F.
    Feldmann, Joerg
    Mello, Paola A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (08) : 1384 - 1393
  • [25] Feasibility of Rare Earth Element Determination in Low Concentration in Crude Oil: Direct Sampling Electrothermal Vaporization-Inductively Coupled Plasma Mass Spectrometry
    Silva, Jussiane Souza
    Henn, Alessandra Schneider
    Dressler, Valderi Luiz
    Mello, Paola Azevedo
    Moraes Flores, Erico Marlon
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 7064 - 7071
  • [26] Isotope dilution as a calibration method for solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    Vanhaecke, F
    Boonen, S
    Moens, L
    Dams, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) : 125 - 130
  • [27] Determination of mercury in fish samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    Liaw, MJ
    Jiang, SJ
    Li, YC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (06) : 779 - 785
  • [28] Slurry sampling electrothermal vaporization inductively coupled plasma Mass spectrometry for the determination of As and Se in soil and sludge
    Tseng, Yen-Jia
    Liu, Chung-Chang
    Jiang, Shiuh-Jen
    ANALYTICA CHIMICA ACTA, 2007, 588 (02) : 173 - 178
  • [29] Magnetic solid phase microextraction on a microchip combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for determination of Cd, Hg and Pb in cells
    Chen, Beibei
    Heng, Shujing
    Peng, Hanyong
    Hu, Bin
    Yu, Xu
    Zhang, Zhiling
    Pang, Daiwen
    Yue, Xin
    Zhu, Ying
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (12) : 1931 - 1938
  • [30] Direct determination of trace amounts of silicon in polyamides by means of solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    Resano, M
    Verstraete, M
    Vanhaecke, F
    Moens, L
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 897 - 903