Detection of hepatocellular carcinoma: Comparison of dynamic three-phase computed tomography images and four-phase computed tomography images using multidetector row helical computed tomography

被引:25
|
作者
Kim, SK
Lim, JH
Lee, WJ
Kim, SH
Choi, D
Lee, SJ
Lim, HK
Kim, H
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul 135710, South Korea
关键词
computed tomography (CT); helical; technology; liver; CT; liver neoplasms; diagnosis;
D O I
10.1097/00004728-200209000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of our study was to assess the value of additional early arterial phase computed tomography (CT) imaging in the detection of hepatocellular carcinoma (HCC) by comparing three-phase and four-phase imaging by using multidetector row helical CT. Methods: Twenty-five patients with 33 HCCs underwent four-phase helical CT imaging. The diagnosis was established by pathologic examination after surgical resection in 19 patients and by biopsy in six. Four-phase CT imaging comprises early arterial, late arterial, portal venous, and delayed phase imaging obtained 25 seconds, 45 seconds, 75 seconds, and 180 seconds after the start of contrast material injection using multidetector row helical CT. Three-phase CT images (late arterial, portal venous, and delayed phase) and four-phase CT images (early arterial, late arterial, portal venous, and delayed phase) were interpreted independently for the detection of HCC by three blinded observers on a segment-by-segment basis. Sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve (Az) for three-phase CT images and four-phase CT images were calculated. The enhancement pattern of HCC was analyzed on early arterial and late arterial phase imaging. Results: The mean sensitivity of three- and four-phase CT images was 94% and 93%, respectively. The differences between sensitivities were not statistically significant (all p > 0.05). The mean specificities of three- and four-phase CT images were 99% and 98%, respectively. The differences between the specificities were not statistically significantly (all p > 0.05). Neither were the mean areas under the ROC curve for four-phase CT images (Az = 0.976) and three-phase CT images (Az = 0.971) statistically significant (p > 0.05). On early arterial phase imaging, 16 HCCs were hyperattenuating and 17 HCCs were isoattenuating. On late arterial phase imaging, 24 HCCs were hyperattenuating and nine HCCs were isoattenuating. Conclusions: Additional early arterial phase imaging did not improve the detection of HCC compared with three-phase CT images, including late arterial, portal venous, and delayed phase imaging.
引用
收藏
页码:691 / 698
页数:8
相关论文
共 50 条
  • [21] Automatic Diagnosis of Hepatocellular Carcinoma and Metastases Based on Computed Tomography Images
    Zossou, Vincent-Beni Sena
    Gnangnon, Freddy Houehanou Rodrigue
    Biaou, Olivier
    de Vathaire, Florent
    Allodji, Rodrigue S.
    Ezin, Eugene C.
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, : 873 - 886
  • [22] Demonstration of the Anatomy of the Esophageal Artery Using Multidetector-Row Helical Computed Tomography
    Kato, Takumi
    Takase, Kei
    Ichikawa, Hirofumi
    Satomi, Susumu
    Takahashi, Shoki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (06) : 939 - 944
  • [23] Imaging well-differentiated hepatocellular carcinoma with dynamic triple-phase helical computed tomography
    Li, C-S
    Chen, R-C
    Tu, H-Y
    Shih, L-S
    Zhang, T-A
    Lii, J-M
    Chen, W-T
    Duh, S-J
    Chiang, L-C
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (944): : 659 - 665
  • [24] Assessment of cardiac function using multidetector row computed tomography
    Orakzai, Sarwar H.
    Orakzai, Raza H.
    Nasir, Khurram
    Budoff, Matthew J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (04) : 555 - 563
  • [25] Assessment of Moyamoya Disease Using Multidetector Row Computed Tomography
    Sugino, Toshiya
    Mikami, Takeshi
    Ohtaki, Shunya
    Hirano, Tohru
    Iihoshi, Satoshi
    Houkin, Kiyohiro
    Mikuni, Nobuhiro
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2013, 22 (05): : 644 - 649
  • [26] Comparison of pancreatic acinar cell carcinoma and adenocarcinoma using multidetector-row computed tomography
    Sumiyoshi, Tatsuaki
    Shima, Yasuo
    Okabayashi, Takehiro
    Kozuki, Akihito
    Nakamura, Toshio
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (34) : 5713 - 5719
  • [27] A comparison of pyelography and various reconstructions of multidetector helical computed tomography urography images for diagnosing urinary obstruction
    Tzeng, Wen-Sheng
    Wu, Reng-Hong
    Huang, Steven Kuan-Hua
    Mak, Chee-Wai
    Liao, Alex Chien-Hwa
    Lin, Victor Chia-Hsiang
    CLINICAL IMAGING, 2012, 36 (06) : 773 - 779
  • [28] Using Multidetector Row Computed Tomography to Evaluate Baggy Eyelid
    Itsuko Okuda
    Masahiro Irimoto
    Yasuo Nakajima
    Shigemi Sakai
    Kazuaki Hirata
    Yukio Shirakabe
    Aesthetic Plastic Surgery, 2012, 36 : 290 - 294
  • [29] Using Multidetector Row Computed Tomography to Evaluate Baggy Eyelid
    Okuda, Itsuko
    Irimoto, Masahiro
    Nakajima, Yasuo
    Sakai, Shigemi
    Hirata, Kazuaki
    Shirakabe, Yukio
    AESTHETIC PLASTIC SURGERY, 2012, 36 (02) : 290 - 294
  • [30] Comparison of pancreatic acinar cell carcinoma and adenocarcinoma using multidetector-row computed tomography
    Tatsuaki Sumiyoshi
    Yasuo Shima
    Takehiro Okabayashi
    Akihito Kozuki
    Toshio Nakamura
    World Journal of Gastroenterology, 2013, (34) : 5713 - 5719