AN APPROACH TO THE REDUCTION OF CONTACT BOUNCE FOR AC CONTACTOR

被引:0
|
作者
Chi, Chieh-Tsung [1 ]
机构
[1] Chien Kuo Technol Univ, Dept Elect Engn, Changhua, Taiwan
关键词
Electromagnetic contactor; Contact bounce; Kinetic energy; Closing phase angle; Simulation; Experiment; SYSTEM;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A new method based on selecting an optimal closing phase angle of ac sinusoidal excitation for the reduction of closing bounce duration of an ac electromagnetic contactor is presented. The proposed approach overcomes the uncontrollable contact bouncing problems imposed by previously described works and deals with systematical method. The attractive features of the proposed method are the reduction of bounce duration while the closing phase angle is optimized and several others important characteristics related to contactor are obtained through theoretical analysis and experimental validations. Computer simulations and prototype experiments, of the proposed method, demonstrate the numerous benefits that are offered by choosing an optimal closing phase angle on purpose.
引用
收藏
页码:3031 / 3044
页数:14
相关论文
共 50 条
  • [31] Research And Design Of AC Contactor For Aircraft
    Xia, Shangwen
    Wu, Jianwen
    Luo, Xiaowu
    Wang, Xiaojun
    Tong, Ziang
    Jia, Bowen
    Yuan, Yang
    Chen, Jun
    29TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2020), 2021, : 375 - 379
  • [32] Research on the device for reliability of AC contactor
    Zhao, Peng
    Li, Kui
    Fu, Changqing
    Proceedings of the 2nd International Conference on Reliability of Electrical Products and Electrical Contacts, 2007, : 349 - 351
  • [33] Circuit simulates contact bounce
    Tiwari, SS
    EDN, 1997, 42 (10) : 126 - 126
  • [34] A STUDY OF CONTACT BOUNCE PHENOMENON
    BARKAN, P
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1967, PA86 (02): : 231 - &
  • [35] Development of an application specific integrated circuit for reduction of contact bounce in three phase contactors
    Kiely, JH
    Nouri, H
    Kalvelage, F
    Davies, TS
    ELECTRICAL CONTACTS-2000: PROCEEDINGS OF THE FORTY-SIXTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2000, : 120 - 129
  • [36] DEVELOP A DE-BOUNCE AND ENERGY-SAVING CHARACTERISTIC AC PM CONTACTOR AND ITS MICROCONTROLLER-BASED ELECTRONIC CONTROL UNIT
    Chi, Chieh-Tsung
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2010, 6 (02): : 423 - 438
  • [37] A New Run-to-Run Approach for Reducing Contact Bounce in Electromagnetic Switches
    Ramirez-Laboreo, Edgar
    Sagues, Carlos
    Llorente, Sergio
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (01) : 535 - 543
  • [38] A high performance AC permanent magnet contactor
    Department of Electrical Engineering, Chienkuo Technology University, No. 1, Chieh Shou N. Rd., Changhua City 500, Taiwan
    WSEAS Trans. Electron., 2008, 7 (313-322):
  • [39] Contact Bounce Phenomena in a MEM Switch
    Peschot, Alexis
    Poulain, Christophe
    Bonifaci, Nelly
    Lesaint, Olivier
    2012 IEEE 58TH HOLM CONFERENCE ON ELECTRICAL CONTACTS (HOLM), 2012, : 49 - 55
  • [40] SWITCH DESIGN SLASHES CONTACT BOUNCE
    HOGAN, BJ
    DESIGN NEWS, 1976, 31 (20) : 48 - 49